Logo Ernst und Sohn

Preview

Author(s):     
 
Dunjic, Viktor; Rudisch, Andreas; Kolbitsch, Andreas
 
Title:     
 

 
Abstract:     
 
The investigations [1] demonstrate that the two-shearfield test is a suitable method for the determination of the shear capacity of masonry. The testing equipment is mounted directly on the wall in order to retain realistic boundary conditions like stiffness, load and prior damage.
The behaviour factor q and the capacity curves of certain masonry walls can be directly obtained from the experimental results and realistic material behaviour in earthquake design can be represented. In particular, existing masonry can be assessed realistically with methods like the response spectrum, the push-over and the capacity spectrum by using the two-shearfield test.
 
Source:     Mauerwerk 20 (2016), No. 5
 
Page/s:     381-387
 
Language of Publication:     German



I would like to buy the article

You can download this article for 25 € as a PDF file (0.95 MB).
The PDF file can be read, printed and saved.
Duplication and forwarding to third parties is not allowed.


Please enter your email address now to start the order process.
The link for the download will be sent to the email address stated after the
order process has been completed.

Your email address


I am an online subscriber

As an online subscriber of the journal "Mauerwerk" you can access this article via Wiley Online Library.

I would like to order "Mauerwerk"

This article has been published in the journal "Mauerwerk". If you would like to learn more about the journal, you can order a free sample copy or find out more information on our website.


Prices include VAT and postage. Prices for 2017/2018.
€ Prices apply to Germany only. Subject to alterations, errors excepted.