abo_giftabo_onlineabo_printabo_studentabo_testangle_leftangle_rightangle_right_filledarrow_big_downarrow_big_down_filledarrow_big_leftarrow_big_left_filledarrow_big_rightarrow_big_right_filledarrow_big_uparrow_big_up_filledarrow_dropdown_downarrow_dropdown_uparrow_small_leftarrow_small_left_filledarrow_small_rightarrow_small_right_filledarrow_stage_leftarrow_stage_left_filledarrow_stage_rightarrow_stage_right_filledcaret_downcaret_upcloseclose_thinclose_thin_filledcontactdownload_thickdownload_thick_filleddownload_thindownload_thin_filledebookeditelement_headlineelement_labelelement_relatedcontentlockmailminuspagepage_filledpagespages_filledphoneplusprintprint_filledquotationmarks_leftquotationmarks_rightsearchsendshareshare_filledshoppingcart_bigshoppingcart_big_filledshoppingcart_headershoppingcart_smallshoppingcart_small_filledsocial_facebooksocial_linkedinsocial_pinterest social_xsocial_xingsocial_youtubesocial_twitteruser_biguser_small

Artikeldatenbank

Filter zurücksetzen
  • Autor(en)

  • Sprache der Veröffentlichung

  • Erschienen

  • Rubrik

Zeitschriften-Selektion

  • Alle auswählenAlle abwählen
Autor(en)TitelZeitschriftAusgabeSeiteRubrik
Diary of Events: Geomechanics and Tunnelling 6/2015Geomechanics and Tunnelling6/2015597-598Diary of Events

Kurzfassung

Keine Kurzfassung verfügbar.

x
Inhalt: Mauerwerk 6/2015Mauerwerk6/2015Inhalt

Kurzfassung

Keine Kurzfassung verfügbar.

x
Graubner, Carl-AlexanderMasonry - fit for the future / Mauerwerk - Fit für die ZukunftMauerwerk6/2015415-416Editorial

Kurzfassung

Keine Kurzfassung verfügbar.

x
Graubner, Carl-Alexander; Förster, ValentinSimplified design concept for slender masonry walls / Vereinfachter Stabilitätsnachweis knickgefährdeter MauerwerkswändeMauerwerk6/2015417-426Fachthemen

Kurzfassung

The verification of safety against buckling of unreinforced masonry walls according to the accurate design procedure of EN 1996-1-1 Appendix G is based on semi-empirical approaches, which do not always realistically describe the load-bearing behaviour. This statement is also supported by an objection of the country Denmark concerning the load capacity function which is regulated in Appendix G. Using new findings about the effects of non-linear material behaviour in case of stability failure this article investigates fundamental questions about the buckling behaviour of masonry walls and transfers these into a simple practical structural design proposal. As a result, the load capacity function can be considerably simplified, the influence of creep can be integrated and the number of input parameters can be reduced.

x
Schwenk Putztechnik with a new concept of brochures / Schwenk Putztechnik mit neuem BroschürenkonzeptMauerwerk6/2015426Firmen und Verbände

Kurzfassung

Keine Kurzfassung verfügbar.

x
Graubner, Carl-Alexander; Koob, BenjaminAnalysis and comparison of the NDPs of various national annexes of Eurocode 6 / Analyse und Vergleich der NDPs verschiedener nationaler Anhänge zu Eurocode 6Mauerwerk6/2015427-440Fachthemen

Kurzfassung

In the national annexes of Eurocode 6, the individual European Member States can define values for nationally determined parameters in various places or add regulations which are not in contradiction to the current European provisions. Consequently - despite a harmonized Eurocode 6 - the normative regulations of the individual Member States differ more or less. However, in the sense of practicability of the standards in Europe, it should be the aim to develop a European standard which is as uniform as possible and which has not to be applied in significantly different ways due to the national regulations. In order to better understand the interests of the other Member States for future generations of standards and to derive potentials of harmonization, the values of the Nationally Determined Parameters (NDPs) of various Member States are compared in this paper. In this context, the extent of the deviations between the different national annexes is examined and on this basis a possible potential of harmonization is identified.

x
Michel, Kenan; Jäger, Wolfram; Steinigen, FrankRedistribution of internal forces in the lateral bracing system / Schnittgrößenumlagerungen bei der GebäudeaussteifungMauerwerk6/2015441-452Fachthemen

Kurzfassung

The lateral bracing system of a building should ensure the stability of the building, in terms of the usability and the total load capacity. The governing loads for the lateral bracing system are horizontal loads due to wind and earthquake. The horizontal loads are traditionally distributed to the bracing elements according to the uncracked elastic state dependent on the bending stiffness in the elastic (uncracked) state. This method does not allow consideration of non-linear effects and load redistribution. Within the framework of the PRB Research Cooperation - Improving the Practical Use of Structural Design Standards through pre-normative work - Subcontract 5: Masonry Construction, Subproject 3: “Large Shear Walls” [7], the cracked or plastic state can be taken into account through a displacement based approach. A matrix formulation for both the linear and cracked states has been derived and implemented.

x
New market orientation of KS-ORIGINAL / Neue Markenausrichtung KS-ORIGINALMauerwerk6/2015452Firmen und Verbände

Kurzfassung

Keine Kurzfassung verfügbar.

x
Gunkler, ErhardReinforced bending load-stressed masonry - Suggestions for future designs / Bewehrtes biegedruckbeanspruchtes Mauerwerk - Vorschläge für zukünftige BemessungenMauerwerk6/2015453-470Fachthemen

Kurzfassung

European standardization bodies are currently working on the amendment to EN 1996-1-1, which will also affect the evaluation of reinforced masonry in Germany. For that reason, discussion suggestions are being made here for revisions to lay the groundwork for building materials evaluations and especially, evaluations of bending load-stressed masonry walls or beams at their serviceability limit state (SLS) for load-bearing capacities. Information already presented in E DIN 1053-3:2008-03 [N3] is being incorporated as well.
Characteristic values for the compressive strength of the masonry parallel to the bed joints fk,∥ are essential for the design of reinforced masonry, although they are currently not included in national application documents for Germany. For the time being, they can be mathematically calculated using conversion factors for the characteristic compressive strength values vertical to the bed joints fk or by using the declared axial compressive strengths of the masonry units.
The ultimate strains for masonry in general should be set consistently at &egr;mu = ∣-0.002∣ as several masonry types do not exhibit higher compressive strain values. The use of steel strains higher than &egr;su = 0.005 does not change any measurement results. Varying stress-strain curves of the constitutive equations on masonry under compressive strain (parabolic, parabolic-rectangular, tension block) lead to differing values of recordable bending moments despite having the same mechanical reinforcement percentage at higher normal forces. Therefore, clear guidelines should be made for the type of applicable constitutive equation for masonry walls under compressive strain. With the introduction of a tension block, the number values of the reduction factors λ for the compression zone height x, which is dependent on limit strains, and where applicable, reduced compressive strength, need to be determined, as with reinforced concrete construction.
A modification of the bending moment based on the second order theory according to [N4] is presented for the calculation of reinforced masonry walls in danger of buckling. The use of reduction factors for the load capacity of the masonry cross section, such as for unreinforced masonry, does not appear to be appropriate as buckling safety evidence because here, the design task is the determination of a required reinforcement cross section.

x
Schermer, DetleffThe simplified calculation method of DIN EN 1996-3 in practice / Das vereinfachte Bemessungsverfahren von DIN EN 1996-3 in der PraxisMauerwerk6/2015471-478Fachthemen

Kurzfassung

The design and detailing of masonry buildings was usually undertaken in the past using the simplified procedure in Section 6 of DIN 1053-1 (1996-11). With the changeover to the new European code, a new procedure has been made available with the simplified calculation method of DIN EN 1996-3, which promises similarly simple and safe handling for the user. The practical implementation of this new code has been underway for some time. The article investigates the standard design cases and explains the innovations and alterations compared to DIN 1053-1.

x
Using synergies: IBU is member of B.A.U.M. e.V. / Synergien nutzen: IBU ist Mitglied bei B.A.U.M. e.V.Mauerwerk6/2015478Firmen und Verbände

Kurzfassung

Keine Kurzfassung verfügbar.

x
Emhee, AlfredSound insulation in multi-storey residential buildings / Schallschutz im Geschosswohnungsbau - Guidance on how to provide protection against the transmission of air-borne noise from other living areas / Ausführungsempfehlungen zum Schutz gegen Luftschallübertragung aus fremden WohnbereichenMauerwerk6/2015479-485Berichte

Kurzfassung

Keine Kurzfassung verfügbar.

x
Balthasar Neumann Award 2016 European Prize for Architecture and Engineering / Balthasar-Neumann-Preis 2016 Europäischer Preis für Architektur und IngenieurleistungenMauerwerk6/2015486Wettbewerbe

Kurzfassung

Keine Kurzfassung verfügbar.

x
Aktuell: Mauerwerk 6/2015Mauerwerk6/2015487-490Aktuell

Kurzfassung

Extra occupational continuing educations regarding the topic of Nearly Zero Energy Buildings / Berufsbegleitende Weiterbildungen zum Thema Niedrigstenergiegebäude
Renovation and extension of the Wasser- und Schifffahrtsamt Kiel-Holtenau (Kiel-Holtenau Waterways and Shipping Office) / Sanierung und Erweiterung des Wasser- und Schifffahrtsamts Kiel-Holtenau

x
Termine: Mauerwerk 6/2015Mauerwerk6/2015490Veranstaltungen

Kurzfassung

Keine Kurzfassung verfügbar.

x
Inhalt: Stahlbau 6/2015Stahlbau6/2015Inhalt

Kurzfassung

Keine Kurzfassung verfügbar.

x
Lener, GerhardDie österreichischen Stahlbauer sind im internationalen Wettbewerb erfolgreich! - Zum 30. Österreichischen StahlbautagStahlbau6/2015373Editorial

Kurzfassung

Keine Kurzfassung verfügbar.

x
Espinha, Miguel; Greiner, Hansjörg; Ziegler, RenéGateway to Baku - Die Stahl-Glas-Gebäudehülle des neuen Flughafenterminals in AserbaidschanStahlbau6/2015374-379Fachthemen

Kurzfassung

Am Flughafen Baku in Aserbaidschan wurde das neue Terminalgebäude für den Flugbetrieb eröffnet. Dieses gemeinsam mit einem internationalen Team von Planern entwickelte Projekt zeigt bespielhaft die Herausforderungen beim Bauen in der Region. Im folgenden Artikel wird der Prozess von der Geometriebeschreibung über die Entwicklung des Tragwerkskonzeptes unter besonderer Berücksichtigung der Erdbebenbeanspruchung sowie deren Auswirkung auf das Toleranzkonzept der Gebäudehülle skizziert. Weiterhin wird auf die Besonderheiten der Fertigungsprozesse sowie auf die Anforderungen an die Montageabläufe näher eingegangen, die es im Zuge der Realisierung dieser anspruchsvollen Geometrie des Terminals als Stahl-Glas-Struktur zu berücksichtigen gab.

Gateway to Baku - The steel and glass building envelope of the new airport terminal in Azerbaijan.
The new terminal building was opened at the Baku airport (Azerbaijan) for flight operations. Developed in collaboration with an international team of planners project shows the challenges that need to be tackled when building in the region. The present article presents the development process for the geometry and the structural concept, with special emphasis on the severity of the seismic load and its consequences on the design of the tolerance concept for the building envelope. Furthermore, a presentation is made of the particularities of the complex fabrication and installation processes that made the realization of such a challenging geometry out of a steel-glass structure possible.

x
Dorrer, GüntherDie Retheklappbrücke in Hamburg - Besonderheiten aus dem StahlbauStahlbau6/2015380-386Fachthemen

Kurzfassung

Im Jahre 1934 wurde die heute noch in Betrieb befindliche Rethe-Hubbrücke in Hamburg errichtet, welche ab 2016 durch die neue Rethebrücke ersetzt werden wird. Die neue bewegliche Brücke wird als zweiflügelige Klappbrücke in Stahlbauweise mit einer Spannweite von 104,2 m zwischen den Drehlagern errichtet. Im Gegensatz zu der bestehenden Rethequerung erhalten die Verkehrsträger Straße und Schiene bei der neuen Brücke getrennte Überbauten, die auf gemeinsamen Unterbauten sitzen. Für den Schiffsverkehr vergrößert sich die Durchfahrtsbreite um 20,0 m auf 64,0 m. Die Gesamtbreite der Straßenklappbrücke beträgt 14,0 m, die der Bahnklappbrücke 10,3 m. Die Brückenklappen werden über einen hydraulischen Antrieb mittels Hydraulikzylindern zwischen der Verkehrs- und Hochlage bewegt. Eine Besonderheit der Rethebrücke liegt in der Ausführung der Mittenverriegelung als Fingerverriegelung ohne bewegte Teile. Die neue Rethebrücke ist nach ihrer Fertigstellung die größte Klappbrücke Europas und der Hamburger Hafen ist um ein Highlight der Ingenieurbaukunst reicher.

The Rethe Bridges in Hamburg - Special features in structural steelwork.
The existing Rethe Vertical Lift Bridge was built in 1934 and will substitute by the new bridge across the Rethe. It consists of two double-leaf bascule bridges with a span of 104.2 m each between the pivot bearings. In an open condition the width of the shipping clearance will be increased from 44 m to 64 m and unlimited in height. One of the double-leaf bascule bridges is used for rail traffic, the other one for road traffic. The two bridges are arranged next to each other and can be opened independently of each other. The overall width of the road bascule bridge is 14.0 m, the overall width of the railway bridge 10.3 m. The spans or leafs are driven by hydraulic cylinders and hydraulically driven rear locking devices. One special feature of the Rethe Bridge is the fact that the central locking unit consists of a finger locking system without any movable parts. After its completion the Rethe Bridge is going to be the largest bascule bridge in Europe and a new highlight of civil engineering.

x
Lechner, Martin; Menzel, Andreas; Fiebinger, RainerDie Retheklappbrücke in Hamburg - Besonderheiten aus Maschinenbau und ElektrikStahlbau6/2015387-395Fachthemen

Kurzfassung

Die neue Doppelklappbrücke wird ab 2016 die 1934 erbaute Rethehubbrücke in Hamburg ersetzen. Sie besteht in Summe aus vier Brückenklappen, von denen jeweils zwei mittels einer Mittenverriegelung in Längsrichtung gekoppelt sind. Jede Klappbrücke hat eine Spannweite von 104,2 m zwischen den Drehlagern und gehört damit zu den weltweit größten ihrer Art. Im hochgeklappten Zustand öffnet sich eine Fahrrinne für den Schiffsverkehr von 64 m Breite und unbegrenzter Höhe. Eine Klappbrücke bedient den Eisenbahnverkehr, die andere den Straßenverkehr. Die Klappbrücken sind nebeneinander angeordnet und unabhängig voneinander bewegbar. Die Gesamtbreite der Straßenklappbrücke beträgt 14,00 m, die Gesamtbreite der Bahnklappbrücke 10,30 m. Die Brückenklappen verfügen über einen hydraulischen Antrieb mittels Hydraulikzylindern und hydraulisch betriebenen Rückarmriegeln. Eine Besonderheit liegt in der Ausführung der Mittenverriegelung als Fingerverriegelung ohne bewegte Teile. Diese Mittenverriegelung überträgt sowohl Querkräfte als auch Biegemomente. Im Juli 2014 wurden die Brückenklappen mittels Schwimmkran eingehoben, auf den Drehlagerböcken aufgesetzt und mittels des Hydraulikantriebs in die Hochlage geklappt

The Rethe Bascule Bridge in Hamburg - Particular features about mechanics and electrics.
The new double bascule bridge in Hamburg will substitute the Rethe vertical lift bridge from 1936 by 2016. In total it consists of four bridge leaves, of which each two are connected longitudinally by a middle locking system. Each bascule bridge shows a span of 104.2 m in-between the pivot bearings and therefore belongs to world’s largest of its kind. In raised condition a watercourse of 64 m width and unlimited height is opened. One bascule bridge serves for rail traffic, the other one for road traffic. The bascule bridges are located side by side and may be actuated independently of each other. The total width of the road bascule bridge is 14.00 m, of the railway bascule bridge 10.30 m. The bridge leaves dispose of a hydraulic drive by means of hydraulic cylinders and hydraulically actuated rear locks. One particularity inherited is the realization of the middle locking system as finger locking without movable parts. This middle locking device is able to transmit shear forces as well as bending moments. In July 2014 the bridge leaves were lifted in by a floating crane, positioned on the pivot bearing substructure and lifted into open position by the hydraulic drive.

x
Kirchhofer, Johannes; Kirchmaier, WolfgangBogenbrücke Lambach, Österreich - Eine Bogenbrücke als integrale LösungStahlbau6/2015396-401Fachthemen

Kurzfassung

Die 60 m lange Bogenbrücke nahe Edt bei Lambach ist nicht nur aufgrund ihrer nicht alltäglichen Widerlagersituation eines der markanten Bauwerke der neuen 5,1 km langen Umfahrung der B1 Wiener Straße rund um Lambach. Die Bogenbrücke zeichnet sich als reine Stahllösung aus und bildet so ein eher seltenes Bild unter den Straßenbrücken Oberösterreichs. Aufgrund des geringen Montagezeitfensters und der durch die querende Westbahnstrecke begrenzten Verschubzeiten stellte die Stahlbogenbrücke mit orthotroper Fahrbahnplatte die einzige Möglichkeit dar, die Westbahnquerung in Anbetracht der gegebenen Rahmenbedingungen zu realisieren. Im Folgenden werden die Konstruktionsmerkmale der Brücke kurz erläutert sowie ein Überblick über das Montage- und Verschubkonzept gegeben.

Arch bridge at Lambach, Austria.
The 60 m long arch bridge near Edt at Lambach is one of the prominent constructions along the new 5.1 km long by-pass road of the B1 Wiener Straße around Lambach - not least because of its exceptional bearing solution. Its genuine steel construction makes it a true exception among the road bridges of Upper Austria. Building a steel arch bridge with an orthotrophic deck was the only way to traverse the Westbahn Rail Track within the given conditions: short installation time and limited time slots for moving the bridge across the Westbahn Tracks. This paper shall present the constructional features of the bridge and give an overview of the installation and positioning concept.

x
Konzeptwettbewerb zur die Gründung neuer SchülerforschungszentrenStahlbau6/2015401Firmen und Verbände

Kurzfassung

Keine Kurzfassung verfügbar.

x
Petraschek, ThomasBedarfsgerechte Instandsetzung der Korrosionsschutzbeschichtung von Eisenbahnbrücken aus StahlStahlbau6/2015402-409Fachthemen

Kurzfassung

Die Eisenbahnbrücke über den Inn zwischen Braunau in Österreich und Simbach in Deutschland, die neue Hilfsbrückengeneration der ÖBB-Infrastruktur AG und die Eisenbahnbrücke Nußdorfer Schleusenwerke haben trotz unterschiedlichster Konstruktionen, Anlagenalter und Verwendungszweck eine globale Gemeinsamkeit. Alle drei Konstruktionen sind Stahlkonstruktionen, die zur Einhaltung ihrer geplanten Nutzungsdauer eine Beschichtung benötigen. In allen drei Fällen haben die gängigen, dazu vorhandenen Regelwerke nicht die ausreichende Grundlage geschaffen, eine zielgerichtete, effiziente und auch kostengünstige Umsetzung der Beschichtung festlegen zu können.
Anhand der drei Beispiele wird im nachfolgenden Beitrag aufgezeigt, wie sich die ÖBB-Infrastruktur AG der trotz alledem sehr guten normativen Grundlagen bedient, diese aber mit auf den Einflussgrößen Umweltrandbedingungen und Stahlbaudetaildurchbildung aufbauenden zeitabhängigen Verfallskurven ergänzt und so nunmehr abweichend dazu neue Wege geht, um im Sinne des Life-Cycle-Managements bei der Festlegung der Maßnahme die richtige Maßnahme zum richtigen Zeitpunkt zu detektieren.

Reconditioning of the corrosion protection coating of steel railway bridges as really needed.
The railway bridge crossing the Inn near Braunau, the new generation of auxiliary bridges of the ÖBB-Infrastruktur AG and the railway bridge called Nußdorfer Schleusenwerke have in spite of different steel structures, different age of structure and different purpose of use one global similarity. All three are steel bridge structures which need coating systems to achieve their planned service life. In all three cases there are no really useful standards to determine an efficient, purposeful and low-cost solution.
Based on these three samples this paper will show a way the ÖBB-Infrastruktur AG went to dedicate a solution combining the really good contents of the existing standards with models for degradation including boundary conditions as environment and structural steel details. At the end there should be the right action at the right time.

x
13. Fachplanertag Brandschutz IngKH - Brandschutzlösungen von der Flüchtlingsunterkunft bis zur WindkraftanlageStahlbau6/2015409Aktuell

Kurzfassung

Keine Kurzfassung verfügbar.

x
Rusch, Karl Heinz; Klapper, GeorgSegmentverschlüsse im Stahlwasserbau - Flexible Anwendung bei unterschiedlichen Anforderungen und BauwerkenStahlbau6/2015410-416Fachthemen

Kurzfassung

Segmentverschlüsse sind in Europa eine weit verbreitete Verschlussart. Die hohe Flexibilität und die Anpassung an bestehende Bauwerke und Neubauten sind Merkmale, die sowohl für Planer als auch für Betreiber von entscheidendem Vorteil sind. Segmentverschlüsse werden in verschiedenen Bereichen eingesetzt. Sie finden Verwendung als Grundablass in Stollen und Talsperren, aber auch bei Wehranlagen mit großer lichter Weite. Ausgehend von der Vielzahl an existierenden Lösungen gibt der Aufsatz Einblick in die verschiedenen Ausführungen und Problemlösungen sowie allgemeine konstruktiven Ansätze.

Radial gates for steel civil construction hydraulics - Flexible applications by different requirements and structures.
Radial gates are widely used in Europe as lock systems in water ways. The high flexibility in easily adapting to existing and as well to newly built structures are one of the features creating advantages for consultants and as well for the operating companies. Radial gates are used as bottom outlets in tunnel and dams and also on weir structures with huge span. Based on a number of executed projects this report gives an overview of different applications where this technology has been used to approach the given challenges.

x