Journal articles
Author(s) | Title | Journal | Issue | Page | Category |
---|---|---|---|---|---|
Zhang, Wei; Wu, Mengxue; Zhu, Jin | Evaluation of vehicular dynamic effects for the life cycle fatigue design of short-span bridges | Steel Construction | 1/2017 | 37-46 | Articles |
AbstractDedicated to Prof. Dr. Akimitsu Kurita on his 70th birthday x | |||||
Zhang, Wei | Experimental study on fatigue behaviour of CFRP plates externally bonded to concrete substrate | Structural Concrete | 2/2016 | 235-244 | Technical Papers |
AbstractThe behaviour of the bond between fibre-reinforced polymers (FRP) and concrete greatly influences the behaviour of concrete structures strengthened with FRP composites. Although numerous experimental studies have investigated this bond, experimental data concerning fatigue tests on carbon FRP plates attached to concrete blocks are still lacking. Therefore, a series of double-lap shear tests under monotonic and fatigue loadings were performed on concrete prismatic specimens reinforced with CFRP plates. First, a series of experimental investigations are summarized. Thereafter, the fatigue behaviour of CFRP plate debonding is characterized using S-N diagrams that represent the relationship of the upper-limit fatigue load with the monotonic load strength and the number of cycles to debonding on a semi-logarithmic scale. x | |||||
Zhang, Min; Wan, Tianbao; Wang, Yingliang | The Design of Langqi Min River Bridge, Fuzhou, China | Steel Construction | 4/2012 | 244-249 | Reports |
AbstractOne key project in the Chinese city of Fuzhou is Langqi Min River Bridge, which connects the business and technology district with downtown Fuzhou. The main bridge is a twin-pylon cable-stayed structure with a main span of 680 m and a steel box girder. This paper presents the detailed design features of the bridge, including foundations, anti-ship collision devices, pylons, steel box girder and stay cables. x | |||||
Zhang, Chun-Liang | Deformation of clay rock under THM conditions | Geomechanics and Tunnelling | 5/2015 | 426-435 | Topics |
AbstractAs a potential host rock for deep geological disposal of radioactive waste, the Callovo-Oxfordian and Opalinus clay rocks have been extensively investigated in the laboratory with respect to deformation under various thermo-hydro-mechanical conditions: (1) stresses covering the range from the initial lithostatic state to redistributed levels after excavation, (2) humidity variations representing ventilation during operation of tunnels as well as water migration from the far-field and (3) heating from ambient temperature up to 100 °C and a subsequent cooling phase. For these highly consolidated clay rocks, a new concept is theoretically derived to explain the effective stress in the particle matrix and experimentally confirmed. The mechanical deformation of the clay rocks is determined by means of short- and long-term compression experiments on quasi water-saturated samples at ambient temperature. Reponses of the clay rocks to humidity changes are examined by drying and wetting the samples under different loading conditions. Thermal effects are studied by heating and cooling the stressed samples under drained and undrained conditions. The main findings are presented and discussed in this paper. x | |||||
Zhang, Boshan; Chen, Weizhen; Xu, Jun | Shear behaviour of girders with trapezoidal corrugated steel webs - an experimental study | Stahlbau | 8/2018 | 810-819 | Fachthemen |
AbstractPresently, numerical analysis of the finite element method and small-scale tests are commonly adopted in researches on the shear behaviour of girders with corrugated steel webs, but these two methods are unable to deal well with the effects of construction flaws in actual structures. Besides, in the case of girders with trapezoidal corrugated webs, most studies took steel I-shaped specimens with vertical webs and thin flanges as research objects, and these cannot represent girders with inclined webs or composite flanges. Therefore, a full-scale corrugated steel web girder with inclined flanges was tested. The failure mode and shear strength of the girder were investigated. The results show that the shear resistance of flanges should not be ignored. Out-of-plane deformation develops in the web from the start of loading owing to initial geometric imperfections, and buckling failure occurs in areas where out-of-plane deformation develops fastest. x | |||||
Zhang, Boshan; Chen, Weizhen; Xu, Jun | Load effect and fatigue damage of bridges under combined actions of traffic and wind: a case study | Stahlbau | 4/2016 | 281-291 | Fachthemen |
AbstractStudy of load effects on bridges with large windward sides has to consider not only passing vehicles but also wind actions. This paper concerns the method to calculate actual load effect and fatigue damage under combined actions of traffic and wind, taking one of the steel rods of Anyang Bridge as an example project. Firstly, internal force time-history of the rod was simulated based on measured data of traffic load and wind field. Then, extreme values of internal force of the rod were extrapolated using an improved method based on level crossing, and stress spectra of three fatigue-prone details on the rod were gained using the rain-flow method. Finally, the rod was checked under ultimate limit state and fatigue limit state, respectively. It was found that characteristic values of internal force of the rod under combined actions of traffic and wind increased from +5 849/-4 063 kN (considering vehicle actions alone) to +6 350/-5 466 kN and the maximum damage degree of fatigue-prone details increased from 0.61 (considering vehicle actions alone) to 0.63. These results suggest that wind load contributes a significant increase to internal force characteristic values of the rod but a small increase to fatigue damage. However, high stress amplitudes due to wind load do not allow infinite life design. The actual load level is much higher than that prescribed in the design code. Hence, wind actions should be fully considered. x | |||||
Zha, X.; Nocke, Ch.; Häusler, C.; Wenski, H. | Lösungen raumakustischer Probleme mit mikroperforierten transparenten Bauteilen | Bauphysik | 6/1998 | 198-208 | Fachthemen |
AbstractUm Optik, Haptik und Akustik in auch akustisch anspruchsvollen Räumen zu einem harmonischen Dreiklang zu führen, hat das IBP die Entwicklung von mikroperforierten Platten und Folien, z. B. aus Acrylglas, Polycarbonat (aber auch Metall), stark vorangetrieben. Ein- und mehrschalig aufgebaute Absorber lassen sich für senkrechten ebenso wie für schrägen oder diffusen Schalleinfall mit geeigneten Rechenprogrammen exakt auf das jeweilige Spektrum auslegen. Anhand ausgeführter Bau- und Sanierungsvorhaben sollen die Einsatzmöglichkeiten neuartiger faserfreier Absorber und Diffusoren demonstriert werden. Bis zur Marktreife wurden Folienabsorber als Bespannungen, Rollos, Baffles und Segel für beliebige Dach- und Wandflächen zusammen mit drei Lizenzpartnern entwickelt. x | |||||
Zha, X.; Fuchs, H. V.; Drotleff, H. | Eine neue Akustik für vier Sparten - das Große Haus des Staatstheaters Mainz | Bauphysik | 3/2003 | 111-121 | Fachthemen |
AbstractDem Anfang des 19. Jahrhunderts für 1500 Besucher konzipierten Bauwerk des Hofbaumeisters G. Moller wird eine gute Akustik nachgesagt. Zahlreiche bauliche Veränderungen, insbesondere der Wiederaufbau von 1951, führten aber nach Meinung der Chronisten ins Abseits. Die Rekonstruktion am Beginn des 21. Jahrhunderts verlangte nicht nur eine Rückbesinnung auf die ursprüngliche architektonische Idee, sondern auch ein raumakustisches Konzept, das den zukünftigen Anforderungen an ein Haus für Schauspiel, Ballett, Oper und Konzert gewachsen ist. Der Forderung einer gemeinsamen Arbeitsgruppe der Stadt Mainz und des Landes Rheinland-Pfalz folgend, wurde deshalb 1999 eine Neubewertung aller Maßnahmen zur Optimierung der Akustik vorgenommen. x | |||||
Zha, X.; Fuchs, H. V. | Schallfeldsimulation mit Spiegelquellen - Eine Planungshilfe für reflexionsarme Räume | Bauphysik | 4/2009 | 208-215 | Fachthemen |
AbstractKonventionelle Auslegungen von akustischen Freifeldräumen nach ISO 3745 sind häufig mit Risiken behaftet, weil die übliche Annahme eines Absorptionsgrades bei senkrechtem Schalleinfall von 99 % herkömmlicher faseriger oder poröser Auskleidungen von Fall zu Fall weder notwendig noch ausreichend sein kann. Es wird ein Simulationsprogramm vorgestellt, das mit der phasenrichtigen Überlagerung der Schallwellen einer realen Punkt- und einer Serie von Spiegelquellen arbeitet, welche die unvollständig absorbierenden Begrenzungsflächen des Raumes ersetzen. Damit werden verschiedene Einflüsse aufgezeigt, die die Freifeldeigenschaften ebenso stark beeinflussen können wie der Absorptionsgrad der Auskleidung. So lässt sich bereits in einem frühen Planungsstadium mehr Sicherheit über die Qualität eines Akustik-Prüfstandes zur Bestimmung von Schallleistung, Spektrum und Richtcharakteristik technischer Schallquellen gewinnen. x | |||||
Zha, X.; Drotleff, H.; Nocke, Ch. | Raumakustische Verbesserungen im Probensaal der Staatstheater Stuttgart | Bauphysik | 4/2000 | 232-239 | Fachthemen |
AbstractDer für großes Orchester und Chor intensiv genutzte Probensaal der Staatstheater Stuttgart wurde im Rahmen einer Sanierungsmaßnahme im Sommer 1999 vollständig umgebaut und raumakustisch neu gestaltet. Im Gegensatz zu Aufführungsräumen sind an Probenräume grundsätzlich andere Anforderungen zu stellen. In diesem zentralen Probenraum sollten die Arbeitsbedingungen der Musiker hinsichtlich Lautstärkeentwicklung und akustischer Transparenz nachhaltig verbessert werden. Aus akustischer Sicht waren der Raum insgesamt zu klein, die äquivalente Absorptionsfläche ungünstig verteilt und die schallreflektierenden Einbauten falsch plaziert. Es werden die Ausgangssituation, die durchgeführten Baumaßnahmen sowie die dadurch erreichten Verbesserungen beschrieben. Alle Nutzer, Musiker und Sänger ebenso wie Dirigenten und die Intendanz, äußern sich sehr zufrieden über die neuen Arbeitsbedingungen. x | |||||
Zeuli, Vincenzo; Maier, Christof; Diaz, José Manuel Suarez; Saeed, Fahed Ahmed; Tharamapalan, Jayapregasham; Germani, Carlo; Bayer, Lars; Atzl, Georg | Structural design of precast segmental lining reinforced by steel fibres | Geomechanics and Tunnelling | 4/2021 | 356-366 | Topics |
AbstractDubai Municipality awarded to Porr Besix JV the Project for the Main Tunnel component of the Deep Storm Water System. The tunnel will collect both rainwater and groundwater from approximately 500 sq. km and transfer the captured flow to the sea. The Design Builder JV selected COWI as Designer of the entire Project and IC Consultant as Design Checker for the Tunnels. The Project includes approximately 10.3 km of 10-meter-inside diameter tunnel in rock, three construction shafts and one drop shaft. The main tunnel will convey stormwater and groundwater flows from the EXPO 2020 area near the intersection of Sheikh Mohammed Bin Zayed Road and Jebal Ali Lehbab Road to the sea close to the EGA facility. The tunnel will follow beneath the road easement along Jebal Ali Lehbab Road and along Sheikh Zayed Road and continue to the pumping station. The tunnel traversed through the Barzaman and Fars formation with an overburden of 33 m with maximum water pressure of 4.4 bar and was excavated by EPB TBMs. This project is characterized by its dimensions with an internal diameter of 10 m and 350 mm of segment thickness, and by the use of steel fibre reinforced concrete in the precast segmental lining. The use of fibres aims to reduce the CO2 footprint obtaining an optimized design from the environmental point of view. These facts are associated to a complex design of precast segments, in order to ensure their structural competence and their integrity according to the durability requirements, under large thrust forces (temporary loads) and permanent load. Hence, considering such complexities, the structural design has been carried out producing a 3D structural model by means of a sophisticated FEM structural software. Results of the model allow to identify areas of the segment where spalling and bursting stresses are generated along circumferential joints and maximum value of those stresses in the temporary load cases. Moreover, a structural design verification of the segment has been undertaken considering the contribution of steel fibres class 4c, as it is set up in the FIB model code, aiming to ensure that the precast segments are structurally competent and fulfil the durability requirements of the Project. The article details the design approach and the independent checker design verification approach. The experience gained during construction is also reported, describing challenging aspects of the Tunnel execution and an analysis of the lining damages. x | |||||
Zettler, A.; Poisel, R.; Preh, A.; Konietzky, H. | Tunnelling in swelling rock - a solved problem? / Vortrieb in quellendem Gebirge - ein gelöstes Problem? | Geomechanics and Tunnelling | 5/2010 | 557-566 | Topics |
AbstractIn some sedimentary rocks, the admission of water results in an expansion of volume, which results from the chemical conversion of anhydrite into gypsum (anhydrite swelling) or the physical adsorption of water in certain clay minerals (clay swelling). This expansion leads to heavy loading of the tunnel lining and has already caused significant damage to some structures. In addition, sulphate attack on the lining concrete can lead to softening due to the formation of ettringite. Damage can be in the form of shear failure, spalling or bending tension cracks. The location and nature of the damage, which depends on the location of the ground containing clay or anhydrite and susceptible to swelling, is illustrated with some examples. Numerical modelling is applied to demonstrate the load transfers, which lead to these phenomena. Recent attempts to counter the problem have been based on the strengthening of the lining (resistance principle) or by installing compressible zones between rock mass and lining (yielding principle). The design rules for each principle are explained. x | |||||
Zerwas, M.; Krause, H.-J.; Zens, M.; Frey, T. | Energieausweis nach DIN V 18599 und mittels Gebäudesimulation - ein Projektbericht | Bauphysik | 3/2008 | 174-186 | Fachthemen |
AbstractMit der verbindlichen Einführung der EnEV 2007 zum 01. 10. 2007 wurde die Berechnung des Wärmeschutznachweises bei Nichtwohngebäuden vollständig umgestellt. Konnten z. B. Bürogebäude oder beheizte Hallen bislang nach DIN 4701-10 relativ einfach berechnet werden, so sind nun aufwändige Berechnungen nach DIN V 18599 anzustellen. Gleichzeitig entwickelt sich der Wärmeschutznachweis - beginnend in den 70er Jahren - vom “passiven” Rechennachweis immer stärker zu einem “aktiven” und gewichtigen Planungspart im Entstehungsprozess eines Projektes. Dies ist richtig und auch erforderlich, will man ein energieoptimiertes Gebäudekonzept aufstellen. An Hand eines Projektes wurden die Praxistauglichkeit und der Nutzen für den Bauherren einer Berechnung nach DIN V 18599 mit einer thermischen Gebäudesimulation verglichen. Dabei ergaben sich Fragen der Umsetzung, die in dem Aufsatz behandelt werden. Die EnEV 2007 stellt sicherlich einen weiteren Meilenstein dar, da die Konsequenzen sowohl für den Planungsprozess als auch für den Gebäudeentwurf weitreichend sind. Weitere Fragen wurden aufgeworfen und sind in Zukunft zu beantworten. x | |||||
Zerna, W.; Schultz, H.-G. | Neuartiges Konzept leistungsstarker Windkraftanlagen. | Bautechnik | 7/1991 | 227-229 | |
AbstractKonzept zur Leistungsverstärkung von Windkraftanlagen. Mehrere Windenergiekonverter mittelgrosser Leistung sollen in einem Turm (Windenergieturm) installiert werden und somit Einzelanlagen mit einer Gesamtleistung im Megawattbereich geschaffen werden. Es zeigt sich, daß die an einem Turm arbeitenden Rotoren aus aerodynamischen Gründen zweckmässigerweise übereinander anzuordnen sind, so daß sich hohe Türme ergeben. Um sie im Hinblick auf ihre Beanspruchung wirtschaftlich auszubilden, ist eine spezielle Seilabspannung anzubringen. x | |||||
Zerna, W.; Schnellenbach, G. | Zur Berechnung von Spannbeton-Reaktordruckbehältern. | Beton- und Stahlbetonbau | 11/1970 | 255-261 | Fachthemen |
Zerna, W.; Mungan, I. | Über das Beulen von Kühlturmschalen mit Versteifungsringen. | Beton- und Stahlbetonbau | 2/1981 | 33-36 | |
AbstractÜber die Dimensionierung und die optimale Verwendung von rotationssymmetrischen Versteifungsringen bei Naturzugkühltürmen zur Erhöhung des Beulwiderstands der Kühlturmschale. x | |||||
Zerna, W.; Köpper, H.-D. | Spannstahlspannungen im Grenzzustand der Tragfähigkeit bei Trägern mit Vorspannung ohne Verbund. | Beton- und Stahlbetonbau | 1/1989 | 11-16 | |
AbstractVerfahren für die Ermittlung der Spannungszunahme von Spannstählen im Grenzzustand bei ohne Verbund vorgespannten Spannbetonträgern. x | |||||
Zerna, W.; Almannai, A.; Basar, Y.; Mungan, I. | Randbedingungen und Beulverhalten von Kühlturmschalen. | Beton- und Stahlbetonbau | 8/1979 | 200-204 | |
AbstractEs wird über eine Parameterstudie zum Beulverhalten von Kühlturmschalen berichtet. Variiert wurden hierbei die Lagerungsbedingungen am unteren Schalenrand und der Einbau von horizontalen Versteifungsringen in einem bestimmten Abstand. Die Untersuchungen wurden sowohl an Aralditmodellen als auch auf theoretischem Weg durchgeführt und miteinander verglichen. x | |||||
Zerna, W. | Näherungsweise Berechnung des Alterungsbeiwerts für das Betonkriechen. | Beton- und Stahlbetonbau | 10/1986 | 275-278 | |
AbstractFür den eindimensionalen Spannungszustand lässt sich das allgemeine Spannungs-Dehnungsgesetz für Beton unter Berücksichtigung seiner elastischen Verformung sowie des Kriechens und Schwindens unter Verwendung des Alterungskennwerts, auch Relaxationskennwerts formulieren. Der Alterungsbeiwert ist abhängig vom Betonalter und der Beobachtungszeit. Er lässt sich aber auch in Abhängigkeit von den Endkriechzahlen darstellen.Für diesen Fall wird für seine Berechnung ein Näherungsverfahren abgeleitet. x | |||||
Zerna, W. | Fortschrittliche Betonbauten für Wärmekraftwerke. | Beton- und Stahlbetonbau | 3/1982 | 61-69 | |
AbstractEs werden die Einsatzgebiete des Stahlbeton- und Spannbetonbaus bei der Errichtung von Wärmekraftwerken geschildert. Die erforderlichen Kraftwerkskomponenten für konventionelle Energiegewinnung aus fossilen Brennstoffen und für Kernkraftwerksbauten werden beschrieben. Insbesondere für Reaktorgebäude werden die sicherheitstechnischen Aspekte für Lastfälle wie Flugzeugaufprall und Erdbeben untersucht. x | |||||
Zerjeski, B.; Graf, E.; Hardock, D.; Mensinger, M. | Ersatz der Rechenbrücke des denkmalgeschützten Rheinkraftwerks Eglisau | Stahlbau | 2/2008 | 93-98 | Fachthemen |
AbstractDie neue Außenrechenbrücke am denkmalgeschützten Rheinkraftwerk Eglisau in der Schweiz befindet sich zur Zeit im Bau. Das sechsfeldrige Bauwerk ersetzt die vorhandene ca. 156 m lange Brücke. Während des Baus der Unterwasserpfeiler und der Montage der neuen Brücke soll der Außenrechen möglichst übergangslos von der bestehenden Konstruktion aus gereinigt werden. Die Stromproduktion des Kraftwerks muss während der gesamten Bauzeit und des Querverschubs der Brücke aufrechterhalten werden. Der vorliegende Aufsatz beschreibt die statischen, konstruktiven und montagetechnischen Besonderheiten des zum Teil im Wasser liegenden Bauwerks. x | |||||
Zerbst, David; Baensch, Franziska; Pfriem, Alexander; Niemz, Peter | Visko-elastisches Verhalten von Holz-Klebstoff-Verbindungen unter zyklischer Zug-Druck-Belastung | Bautechnik | 11/2016 | 795-800 | Aufsätze |
AbstractIn dieser Arbeit wurde ein Prüfverfahren angewendet, das statische, zyklische Belastung von Klebstofffugen infolge Quellen und Schwinden des Holzes simuliert und plastische Verformungen im niedrigen Lastbereich aufzeigt. Es wurde das elastische Verhalten von Zugscher-Prüfkörpern, welche aus Buchenholz verklebt mit drei verschiedenen Holz-Klebstoffarten (MUF, PRF, PUR) hergestellt wurden, unter zyklischer Zug- und Druck-Belastung untersucht und die Verlust- und Speicherenergie ausgewertet. Alle getesteten Verklebungen wiesen bereits bei sehr niedrigem Lastniveau von 3 MPa viskose Anteile auf, die mit höherer Last zunahmen. Für die PRF-Verklebung wurde bei der Laststufe von 7 MPa ein elastischeres Verhalten beobachtet als für die übrigen Verklebungen. Die für die PUR-Verklebung erfasste ansteigende Verlustenergie deutet auf eine Aufweichung der Klebstofffuge hin. x | |||||
Zenz, Gerald; Obernhuber, Pius; Czerny, Helmut | The great significance of dam safety in Austria / Der hohe Stellenwert der Talsperrensicherheit in Österreich | Geomechanics and Tunnelling | 5/2012 | 631-637 | Topics |
AbstractEach dam and each reservoir is an individual facility, since their foundation conditions are rarely similar. Due to their location, their height and their storage capacity, dams and reservoirs can hold a considerable hazard potential, which is why they are designed conservatively; projects are examined meticulously (e.g. by the Austrian Commission on Dams) and monitored comprehensively during the construction phase and during operation. To guarantee their continuous safety, dams and reservoirs are monitored with great care by the operating company with the help of trained staff and the latest measuring equipment. The most important measurement data are acquired continuously so as to gain an up-to-date impression of the load-bearing behaviour of the dam and its foundation and to be able to react swiftly and efficiently should any changes occur. x | |||||
Zenz, Gerald; Goldgruber, Markus; Feldbacher, Rupert | Seismic stability of a rock wedge in the abutment of an arch dam / Felskeilstabilität im Fundament einer Bogenstaumauer bei Erdbebenbelastung | Geomechanics and Tunnelling | 2/2012 | 186-194 | Topics |
AbstractIt is shown by the fact of recent earthquakes that engineered dam structures are safe structures. Just minor structures and such, which have not been designed on engineering knowledge, have been damaged. To guarantee a safe dam design, it is necessary to account for the loading in an appropriate way together with the geotechnical site conditions. Based on these, the optimum layout of the structure can be found. For the dynamic loading of the dam structure intensive site specific investigations are needed. The interaction with the abutment is in most cases approximated by means of rigid body models, e.g. Londe or Goodman. x | |||||
Zenz, Gerald | Hydraulic and Geotechnical Engineering - Wasserbau und Geotechnik | Geomechanics and Tunnelling | 2/2021 | 114 | Editorials |