Autor(en): | |
Titel: | |
Kurzfassung: | According to the German National Annex to DIN EN 1996-3, a calculative verification of the bracing system may be omitted if, besides other requirements, an obviously sufficient number of sufficiently long shear walls is in place. If it is questionable whether a building complies with this requirement, a time-consuming verification of the bracing system according to DIN EN 1996-1-1/NA is unavoidable. This article therefore presents a simplified verification method for the bracing system, which will prospectively be included in the next revision of DIN EN 1996-3. The simplified bracing verification can already be used as a decision-making aid to omit the calculative bracing verification according to DIN EN 1996-1-1/NA. |
Erschienen in: | Mauerwerk 23 (2019), Heft 5 |
Seite/n: | 300-305 |
Sprache der Veröffentlichung: | Deutsch |
Ich möchte den Artikel kaufen
Diesen Artikel können Sie für 25 € als PDF (0.48 MB) erwerben. Das PDF kann gelesen, gedruckt und gespeichert werden. Eine Vervielfältigung und Weiterleitung an Dritte ist nicht gestattet. |
Ich bin Online-AbonnentAls Online-Abonnent der Zeitschrift "Mauerwerk" können Sie diesen Artikel über Wiley Online Library aufrufen. |