abo_giftabo_onlineabo_printabo_studentabo_testangle_leftangle_rightangle_right_filledarrow_big_downarrow_big_down_filledarrow_big_leftarrow_big_left_filledarrow_big_rightarrow_big_right_filledarrow_big_uparrow_big_up_filledarrow_dropdown_downarrow_dropdown_uparrow_small_leftarrow_small_left_filledarrow_small_rightarrow_small_right_filledarrow_stage_leftarrow_stage_left_filledarrow_stage_rightarrow_stage_right_filledcaret_downcaret_upcloseclose_thinclose_thin_filledcontactdownload_thickdownload_thick_filleddownload_thindownload_thin_filledebookeditelement_headlineelement_labelelement_relatedcontentlockmailminuspagepage_filledpagespages_filledphoneplusprintprint_filledquotationmarks_leftquotationmarks_rightsearchsendshareshare_filledshoppingcart_bigshoppingcart_big_filledshoppingcart_headershoppingcart_smallshoppingcart_small_filledsocial_facebooksocial_linkedinsocial_pinterest social_xsocial_xingsocial_youtubesocial_twitteruser_biguser_small

Artikeldatenbank

Filter zurücksetzen
  • Autor(en)

  • Sprache der Veröffentlichung

  • Erschienen

  • Rubrik

Zeitschriften-Selektion

  • Alle auswählenAlle abwählen
Autor(en)TitelZeitschriftAusgabeSeiteRubrik
Wetzel, Timm; Lange, Jörg; Tichelmann, KarstenZur Bemessung von Stahlstützen im BrandfallStahlbau12/20191136-1143Aufsätze

Kurzfassung

Herrn Prof. Dr.-Ing. Peter Schaumann zum 65. Geburtstag gewidmet
Im Zentrum des Beitrags stehen Untersuchungen zum Tragverhalten zentrisch belasteter Stahlstützen bei erhöhten Temperaturen. Nach einer Beschreibung des generellen Tragverhaltens im Brandfall werden Imperfektionsbeiwerte vorgeschlagen, die für H-Querschnitte eine sichere Bemessung bei Anwendung des gegenwärtigen Nachweisformats der DIN EN 1993-1-2 ermöglichen. Die Imperfektionsbeiwerte wurden mithilfe abgesicherter numerischer Berechnungsmodelle für Temperaturen zwischen 100 °C und 700 °C entwickelt. Ein Vergleich zeigt, dass die Verwendung des Imperfektionsbeiwerts der Norm zu unsicheren Ergebnissen führt, wenn der Fall “Knicken um die schwache Achse” betrachtet wird. Dahingegen sind die Ergebnisse für niedrigere Temperaturen (< 300 °C) zum Teil unwirtschaftlich. Ergänzend werden aus den Imperfektionsbeiwerten geometrische Ersatzimperfektionen abgeleitet, die für den Brandfall eine Berechnung nach Elastizitätstheorie II. Ordnung ermöglichen.

Design of steel columns in case of fire
This article covers the assessment of the load carrying behavior of centrically loaded columns made of double symmetric H-sections at elevated temperatures. After a short description of the general load carrying behavior in the event of fire, imperfection factors are presented which allow a reliable design using the current model of DIN EN 1993-1-2. The imperfection factors were developed with the help of validated numerical calculation models for temperatures between 100 °C and 700 °C. A comparison shows that using the imperfection factors of the code leads to unsafe results when “buckling perpendicular to the weak axis” is considered. Whereas, the results for lower temperatures (< 300 °C) are partly uneconomical. In addition, geometrical imperfections are derived from the imperfection factors, which allow a second order analysis with elastic material behavior.

x
Different load bearing mechanisms in headed stud shear connectors for composite beams with profiled steel sheetingStahlbau12/20191143Empfehlungen der Redaktion

Kurzfassung

Keine Kurzfassung verfügbar.

x
Zehfuß, Jochen; Sander, LisaVereinfachtes Bemessungsverfahren für thermische Einwirkungen von Stützen in StahlbauweiseStahlbau12/20191144-1150Aufsätze

Kurzfassung

Herrn Prof. Dr.-Ing. Peter Schaumann zum 65. Geburtstag gewidmet
In DIN EN 1991-1-2:2010 [1] ist aktuell ein vereinfachtes Verfahren enthalten, das die Berechnung von thermischen Einwirkungen von Bauteilen bei lokalen Bränden ermöglicht. Auf der Grundlage der Arbeiten von Heskestad und Hasemi kann für lokale Brände die Berechnung der Temperaturen im Feuer-Plume und des Netto-Wärmestroms im Bereich der brandbeanspruchten Bauteile im Deckenbereich (Ceiling Jet) vorgenommen werden. Das vereinfachte Verfahren wurde durch experimentelle Untersuchungen validiert und hat sich in der Anwendung bewährt. Im Zuge der Novellierung von EN 1991-1-2 Anhang C soll das vorgenannte Verfahren um neue analytische Bemessungsansätze erweitert werden. Der Vorschlag sieht vor, Netto-Wärmeströme von brandbeanspruchten (vertikalen) Bauteilen, die in Bezug auf die Flammenachse des lokalen Brands versetzt angeordnet sind, zu berechnen. Im Rahmen eines DIBt-Forschungsvorhabens [2] wurde die Plausibilität und Anwendbarkeit des erweiterten Bemessungsverfahrens geprüft. In diesem Beitrag werden die wesentlichen Vereinfachungen und die Anwendung des erweiterten Bemessungsverfahrens für Stahlstützen unter lokaler Brandbeanspruchung gezeigt. Ferner wird eine Validierung anhand von Vergleichsrechnungen zwischen den Ergebnissen des Bemessungsverfahrens, Simulationsergebnissen mit dem CFD-Modell Fire Dynamics Simulator sowie anhand von Messdaten realer Pool- und Holzkrippenbrände vorgenommen.

Simplified design methods for steel columns under localised fire
DIN EN 1991-1-2:2010 [1] currently contains a simplified design method that allows the calculation of thermal effects under localised fires. Based on the work of Heskestad and Hasemi, the temperatures in the fire plume and the net heat flux in the ceiling area (Ceiling Jet) of structural elements under localised fires can be calculated. The design method have been validated by experimental investigations and have proven themselves in application. In the Draft of EN 1991-1-2 Annex C, the mentioned design method are to be extended by new analytical design approach. The new design approach calculates the net heat flux of structural elements (vertical) which are offset to the flame axis of the localised fire. Within the scope of a DIBt research project [2] the plausibility and applicability of the new design approach was tested. In this article the simplifications and the application of the new design approach for steel columns under localised fire are shown. Furthermore, a validation is carried out on the basis of comparative calculations between the results of the new design approach, simulation results with the Fire Dynamics Simulator as well as measurement data of real pool and wood crib fires.

x
Upmeyer, Jens; Kleibömer, Inka; Meyer, PatrickIngenieurmethoden im ParkhausbauStahlbau12/20191151-1159Aufsätze

Kurzfassung

Herrn Prof. Dr.-Ing. Peter Schaumann zum 65. Geburtstag gewidmet
Der Einsatz von Ingenieurmethoden zur Tragwerksbemessung im Brandfall ermöglicht es, ungeschützte Stahl- und Verbundtragwerke in offenen Parkgaragen auch dann zu realisieren, wenn baurechtliche Anforderungen an den Feuerwiderstand gestellt werden. Besonders wirtschaftliche Konstruktionen sind möglich, wenn reale Tragstrukturen unter der Einwirkung realer Brandszenarien nachgewiesen werden. Dazu wird die Temperaturverteilung infolge eines lokalen Brandszenarios in einem Brandsimulationsmodell ermittelt und als Eingangswert an die FE-Software zur thermischen und mechanischen Berechnung der Bauteile übergeben. Hierzu wurde eine Schnittstelle zwischen den Programmen FDS und SAFIR entwickelt.
In diesem Beitrag werden die Grundlagen der Kopplung von FDS und SAFIR erläutert und mit den etablierten Ingenieurmethoden zur Bemessung einer Stahlverbundkonstruktion an einem Beispiel gegenübergestellt. Anhand des mittels verschiedenen methodischen Ansätzen ermittelten Erwärmungs- und Tragverhaltens wird gezeigt, dass die entwickelte Kopplung der Brandsimulations- und FE-Software eine wesentlich wirtschaftlichere Bemessung für offene Parkgaragen ermöglicht, da die Widerstände realitätsnah berücksichtigt werden.

Fire engineering methods for unprotected constructions of car parks
The application of engineering methods for the structural design of open car parks in case of fire enables the usage of unprotected steel or composite constructions, even if building regulations require a certain fire resistance. The construction is especially economical, if the design includes the real structure and natural fire scenarios. Therefore, the temperature distribution due to a local fire scenario is calculated using a field model and is used as a basis for the subsequent thermal and mechanical analysis of the structural elements. An interface between the programs FDS and SAFIR was developed therefore.
This paper presents the basics of the interface between FDS and SAFIR and compares this new method to common engineering methods within a working example. Comparing the thermal and mechanical behaviour of the structural elements determined using the different methods, it is revealed, that using the interface aims in more economic design as the resistance is considered in a realistic manner.

x
The generalized slenderness-based resistance method for the design of SHS and RHSStahlbau12/20191159Empfehlungen der Redaktion

Kurzfassung

Keine Kurzfassung verfügbar.

x
Mensinger, Martin; Gaigl, ChristianR30 mit feuerverzinkten Stahl- und Verbundkonstruktionen - BemessungshilfenStahlbau12/20191160-1166Aufsätze

Kurzfassung

Herrn Prof. Dr.-Ing. Peter Schaumann zum 65. Geburtstag gewidmet
Durch Forschungsergebnisse der Technischen Universität München [1-5] konnte gezeigt werden, dass eine Feuerverzinkung im Brandfall einen positiven Einfluss auf das Erwärmungsverhalten von Stahlbauteilen der Kategorien A und B hat. Grund für die langsamere Erwärmung ist ein kleinerer, variabler Emissionsgrad von feuerverzinkten Oberflächen im Vergleich zu unverzinkten Stahlbauteilen. Im Auftrag des Gemeinschaftsausschusses Verzinken e. V. wurden nun Bemessungshilfen erarbeitet, die eine praxisgerechte einfache Anwendung der Forschungsergebnisse erlauben.

R30 with hot-dip galvanized steel and composite constructions - design aids
Research results of the Technical University of Munich [1-5] showed that a hot-dip galvanizationhas a positive influence on the heating behaviour of steel components of categories A and B in case of fire. The reason for the slower heating is a smaller, variable emissivity of hot-dip galvanized surfaces compared to non-galvanized steel components. On behalf of the Gemeinschaftsausschuss Verzinken e. V., design aids have been developed to allow a practical and easy application of the research results.

x
Lochte-Holtgreven, Stephan; Bechtel, Anne; Raba, Alexander; Wilke, FabianGrout-Verbindungen in stählernen Offshore-Bauwerken - Forschung und Entwicklung am Institut für Stahlbau der Leibniz Universität HannoverStahlbau12/20191167-1175Berichte

Kurzfassung

Herrn Prof. Dr.-Ing. Peter Schaumann zum 65. Geburtstag gewidmet
Grout-Verbindungen als Rohr-in-Rohr-Steckverbindungen mit zementgebundenem Füllmaterial werden seit über 40 Jahren in stählernen Offshore-Plattformen der Öl- und Gasindustrie eingesetzt. Seit mehr als 20 Jahren findet dieser Verbindungstyp auch Anwendung in der Offshore-Windenergie. Da hinsichtlich der eingesetzten Füllmaterialien, der Verbindungsgeometrien und Belastungsszenarien signifikante Unterschiede zwischen Tragstrukturen für Ölplattformen und Windenergieanlagen bestehen, wurde auf dem Gebiet der Grout-Verbindungen am Institut für Stahlbau, Leibniz Universität Hannover intensive Forschung betrieben. Der vorliegende Beitrag berichtet über ausgewählte Erfahrungen und Erkenntnisse zum Trag- und Ermüdungsverhalten von Grout-Verbindungen in Offshore-Windenergieanlagen im Kontext zur historischen Entwicklung der Grout-Verbindungen.

Grouted connections in offshore steel structures - research and development at the Institute for Steel Construction, Leibniz University Hannover
For more than 40 years, grouted connections, such as tube-to-tube-connections with cementitious filling material, are used in offshore steel structures like platforms for oil and gas. Since the early days of the offshore wind energy industry, this type of connection has also been used in substructures for offshore wind turbines and platforms. Compared to grouted connections for offshore oil and gas, other filling materials and geometries are used in support structures for offshore wind turbines. Furthermore, load scenarios for offshore wind turbines are completely different. Thus, the Institute for Steel Construction, Leibniz University Hannover is performing research in the fields of grouted connections since 2004. Also in the historical context, this paper reports on selected experiences and results on the load bearing and fatigue behaviour of grouted connections in substructures for the offshore wind industry.

x
Euler, Mathias; Kuhlmann, UlrikeErmüdung radbelasteter Quersteifenanschlüsse in leichten KranbahnträgernStahlbau12/20191176-1183Aufsätze

Kurzfassung

Herrn Prof. Dr.-Ing. Peter Schaumann zum 65. Geburtstag gewidmet
Die Unterstützungskonstruktion eines Brückenkrans unterliegt einer zyklischen Beanspruchung. Zu dieser Konstruktion zählen insbesondere die Kranbahnträger, die vom Kran bei jeder Kranfahrt überrollt werden. Daher ist ihre Ermüdungssicherheit nach der Bemessungsnorm DIN EN 1993-1-9 nachzuweisen. Für diesen Nachweis müssen die kritischen Konstruktionsdetails des Kranbahnträgers entsprechenden Kerbfällen zugeordnet werden. Allerdings enthält die Bemessungsnorm nur wenige kranbahnspezifische Kerbfälle, die die lokale Belastung des Kranbahnträgers durch die Laufräder des Krans berücksichtigen. Auf der Grundlage von experimentellen Untersuchungen zum Ermüdungsverhalten von radbelasteten Flansch-Steg-Verbindungen wird für ein weiteres kranbahnspezifisches Konstruktionsdetail, den Quersteifenanschluss im Radlasteinleitungsbereich leichter Kranbahnträger, eine Bemessungsempfehlung entwickelt.

Fatigue of transverse stiffeners in light crane runway beams
The supporting structure of an overhead travelling crane is subject to cyclic loading. The crane runway beams are parts of this structure travelled over by the crane during each crane passage. Therefore, their fatigue strength has to be verified according to the design standard DIN EN 1993-1-9. For verification, the critical constructional details of the crane runway beam have to be assigned to a detail category. Indeed, the design standard contains only a few crane-runway specific constructional details accounting for the local stressing through the crane wheels. Based on experimental investigations on the fatigue behaviour of wheel loaded flange-to-web connections, a recommendation for a further crane-runway specific constructional detail, the transverse stiffeners within the wheel load region of light crane runway beams, is developed.

x
On the post-buckling rotational capacity of square hollow sections in uniform bending - An initial study of the impact of initial imperfections on deformation pathsStahlbau12/20191183Empfehlungen der Redaktion

Kurzfassung

Keine Kurzfassung verfügbar.

x
Radtke, Frank Kurt Friedrich; Schubart, RalfBeitrag zur Dimensionierung von Halsnähten luftdichter Hohlkästen unter temperaturinduziertem InnendruckStahlbau12/20191184-1191Aufsätze

Kurzfassung

Herrn Prof. Dr.-Ing. Peter Schaumann zum 65. Geburtstag gewidmet
Dichtgeschweißte Stahlhohlkästen sind eine effiziente und erprobte Bauweise im Stahl- und Stahlverbundbrückenbau. Die Prüfung und Inspektion innen liegender Schweißnähte ist jedoch nur bedingt oder gar nicht möglich, sodass eine robuste Ausführung innen liegender Schweißnähte geboten ist. Nun haben Messungen bestätigt, dass es in dichtgeschweißten Stahlhohlkästen zu nennenswerten Veränderungen des Innendrucks in Abhängigkeit von der Temperatur kommt. Die daraus resultierenden Druckunterschiede zwischen Innen- und Umgebungsluftdruck stellen eine nicht zu vernachlässigende - bisher aber nicht berücksichtigte - zusätzliche Belastung der Halsnähte dar. Es wird ein ingenieurpraktischer Ansatz zur Dimensionierung ebendieser Halsnähte dichtgeschweißter Hohlkästen unter sowohl Schubbelastung aus der Haupttragwerkswirkung als auch Biegebelastung aus temperaturinduziertem Innendruck hergeleitet. Verschiedene Einflussgrößen werden untersucht und die Ergebnisse werden in vereinfachten Berechnungsansätzen zusammengefasst, deren Anwendung kurz dargestellt wird.

Contribution to the design approach of welds in air-tight box girders under temperature induced internal pressure
Air-tight steel box girders have been frequently and successfully used in bridge building during the last years. Only inspection and maintenance of welds and parts inside the box girder proves difficult. This makes a robust design of welds inside necessary. Measurements confirmed that temperature differences lead to substantial changes in inside pressure within an air-tight steel box girder. These pressure differences result in additional, non-negligible - nevertheless so far neglected - increases in loading of welds connecting flanges and webs of box girders. In this contribution we derive a simple design approach for welds in air-tight box girders under shear loading from the main structure as well as bending resulting from temperature induced internal pressure loading. We study the influence of different parameters on the required throat thickness of the welds. Finally, we demonstrate the application of the derived formulation.

x
Hauke, BernhardDas Mannesmann-Hochhaus Düsseldorf - Bauhaus, Moderne und die Leistung der IngenieureStahlbau12/20191192-1199Berichte

Kurzfassung

Das Mannesmann-Hochhaus wurde 1955-1958 am Düsseldorfer Rheinufer für den Industriekonzern als Verwaltungsgebäude neben dem bestehenden Stammhaus gebaut. Dass die Stadtsilhouette prägende Gebäude im Stile der Nachkriegsmoderne ist eines der ersten modernen Hochhäuser Deutschlands. Neben dem Architekten Paul Schneider-Esleben ist es insbesondere das Verdienst des Tragwerksplaners Georg Lewenton, dass dieses schlanke und transparente Gebäude so möglich wurde. Beraten und unterstützt haben auch Fritz Leonhardt (TH Stuttgart) bei den Knaggen-Anschlüssen an die Stützen aus Mannesmannrohren oder Theodor Kristen (TH Braunschweig) bei den Versuchen mit dünnen Brandschutzputzen. Das Mannesmann-Hochhaus ist ein schönes Beispiel, dass sichtbare architektonische Leistungen auch immer die weniger sichtbaren Beiträge der planenden und forschenden Ingenieure und einer innovativen Industrie bedürfen.

x
Stahlbau aktuell 12/2019Stahlbau12/20191200-1213Stahlbau aktuell

Kurzfassung


Im Gespräch:
Im Gespräch mit Sir Philippe Samyn

Weihnachtsaufgabe: Helmut Rubin stiftet Preis für Zusatzaufgabe

Aktuelles: Stahlbau Sonderheft Kranbahnen

Persönliches: Helmut Rubin 80 Jahre
Auszeichnung für Dr.-Ing. Karl Morgen

Wettbewerbe: European Steel Design Awards 2019 in Brüssel vergeben
Tagungen und Veranstaltungen: Neues Bauen mit Stahl - Internationaler Architektur-Kongress erstmals in Düsseldorf

Einen Besuch wert: Ölhafenbrücke Raunheim

Bauforumstahl news: Glanzvoller Auftakt für die Neugestaltung der Preise des Deutschen Stahlbaues
Preis des Deutschen Stahlbaues 2020 ausgelobt
Ingenieurpreis des Deutschen Stahlbaues 2020 ausgelobt
Förderpreis des Deutschen Stahlbaues 2020 ausgelobt
bauforumstahl unterstützt Klimaziele beim Bauen
Neues aus der Normung
VOB 2019 veröffentlicht

x
Kongresse - Symposien - Seminare - MessenStahlbau12/20191213-1214Veranstaltungskalender

Kurzfassung

Keine Kurzfassung verfügbar.

x
Ernst & Sohn (Hrsg.)UBB 12/2019 - GesamtausgabeUnternehmerBrief Bauwirtschaft12/20191-36Gesamtausgabe

Kurzfassung

Keine Kurzfassung verfügbar.

x
Inhalt: Bauphysik 1/2020Bauphysik1/2020Inhalt

Kurzfassung

Keine Kurzfassung verfügbar.

x
Titelbild: Bauphysik 1/2020Bauphysik1/2020Titelbild

Kurzfassung


Zum Titelbild:
Charakteristisch für die historischen Gebäude der Sächsischen Klinik Rodewisch (Einweihung 1893) sind die Satteldächer mit Holzdachstühlen und Schiefereindeckung und die gelben Klinkerfassaden. Der Gebäudekomplex wurde ab 1992 Stück für Stück modernisiert und teilweise unter Denkmalschutz auch komplettsaniert. Für die energetische Ertüchtigung der Außenwände von Haus B9 auf einer Fläche von circa 650 m2 kam deshalb nur ein Innendämmsystem in Frage, siehe Meldung S. 49. (© Foto: UdiDämmsysteme)

x
Bauphysik: Jahresinhaltsverzeichnis des 41. Jahrgangs 2019Bauphysik1/20201-12Jahresinhaltsverzeichnis

Kurzfassung

Keine Kurzfassung verfügbar.

x
Ackermann, ThomasEnergiebedarf versus Energieverbrauch unter Einbeziehung von Langzeitmessungen zum TemperaturverlaufBauphysik1/20201-9Fachthemen

Kurzfassung

Wie der Vergleich des Energiebedarfs mit dem Energieverbrauch von sieben exemplarisch ausgewählten Wohngebäuden zeigt, liegen die Werte beim Bedarf in der Regel über den Angaben für den Verbrauch. Dies ist nicht nur auf den anzusetzenden Bezug - Bedarf oder Verbrauch - zurückzuführen, sondern bei Bedarfsberechnungen kommt erschwerend hinzu, dass der Ansatz von DIN V 18599 immer schlechtere Ergebnisse liefert als der Bezug auf DIN V 4108-6 in Verbindung mit DIN V 4701-10. Außerdem zeigt eine Analyse von Langzeitmessungen der Raum- und Außenlufttemperaturen an 33 Standorten in der Bundesrepublik, dass die wirklichen, zeitlich veränderlichen Temperaturläufe in Gebäuden deutlich von den standardisierten, zeitlich konstanten Werten nach Norm abweichen.

Energy demand versus energy consumption taking into account long-term temperature measurements
The comparison of the energy demand values with the energy consumption values of seven selected residential buildings shows that the determined de-mand values are usually higher than the consumption data. This is not only put down to the reference itself, demand or consumption, but when determining the energy demand by using the approach of DIN V 18599 the results are get-ting worse as by using DIN V 4108-6 in conjunction with DIN V 4701-10. Furthermore, an analysis of long-term measurements of room and outside air temperatures at 33 locations in Germany shows that the real, time-varying temperature curves in buildings clearly diverge from the standardised, temporally constant values according to DIN.

x
Technologieprogramm District Heating and Cooling (DHC) - Internationale Energieagentur (IEA) startet AusschreibungBauphysik1/202010Aktuell

Kurzfassung

Keine Kurzfassung verfügbar.

x
Junghanns, Mike; Rehner, Christian; Schmid, Fabian; Teich, MartienKondensationsrisikobewertung in der Planung von Stahl-Glas-Konstruktionen - Erfahrungen bei der rechnerischen Auslegung und messtechnischen Untersuchung an GroßmusternBauphysik1/202011-26Fachthemen

Kurzfassung

Der Feuchteschutz bei Bauwerken und von Konstruktionen ist essentiell, da nicht nur langfristig Schäden an der Konstruktion ausgeschlossen, sondern auch nutzungsgerechte Raumbedingungen erreicht werden sollen. Die Folgen eines unzureichenden Feuchteschutzes würden die funktionale oder ästhetische Qualität des Bauwerks negativ beeinflussen.
Bei Stahl-Glas-Konstruktionen liegt der Fokus des Feuchteschutzes zunächst auf einem korrekt ausgeführten Korrosionsschutz der Stahlbauteile, da sie das primäre und oft auch das sekundäre Tragwerk bilden. Die Einfassung der Glaselemente wird üblicherweise durch eloxierte oder beschichtete Aluminium-Profil-Systeme erreicht, die hinsichtlich des Korrosionsschutzes unproblematisch sind. Die Beachtung einer korrekten thermischen Trennung, das Fügen von Bauteilen und die fertigungstechnische Qualität entscheiden bei solchen Metallbaukonstruktionen über eine fachgerechte und einwandfreie Ausführung. Das ist wichtig, da bei derartigen Konstruktionen die Kondensation und Tauwasserbildung in der Konstruktion oder an Bauteiloberflächen negative Auswirkungen, wie Wasserablagerungen am Glas oder Tropfenbildung hat und in der Folge andere Gewerke schädigen kann.
Die Einschätzung, inwieweit ein solches Risiko besteht, wird im Planungsprozess typischerweise durch Berechnungen vorgenommen. Bei einer beispielhaften Gitternetzschalenkonstruktion für ein nordamerikanisches Projekt wurden ergänzende messtechnische Untersuchungen an Großmustern, sogenannten Mock-ups, durchgeführt, um unter anderem eine bessere Einschätzung zum Kondensationsverhalten zu erhalten.
Der vorliegende Artikel vergleicht die thermischen Berechnungen an kritischen Details mit den entsprechenden messtechnischen Untersuchungen und zeigt Gründe für Unterschiede und Aussagegenauigkeiten auf. Ergänzend sind relevante Normen und Richtlinien zur Kondensatrisikobewertung für Europa und Nordamerika zusammengefasst und der messtechnische Aufbau dargestellt.

Assessing the condensation risk in the design of steel-and-glass structures - Experiences with computational analysis and measurement studies on true-to-scale prototypes
Control of condensation in buildings and constructions is important, as long-term damages to constructions are eliminated and appropriate interior conditions must be achieved. Otherwise, the consequences of insufficient moisture protection may result in negative impacts on the functional and aesthetic quality of the building.
With steel-and-glass constructions, the focus of moisture protection is primarily the correct corrosion protection of the steel components, as they often serve as the primary and secondary supporting structure. The glass elements are usually mounted on anodized or coated aluminum profile systems, which are unproblematic in terms of corrosion protection. The attention to a correct thermal break, the joint details and the manufacturing quality are crucial for a good and perfect-performing metal construction. This is important, as condensation and dew on the construction or component surfaces can lead to negative effects such as water deposition on the glass or dripping.
The evaluation of the extent to which such a risk exists is typically estimated in the planning process by performing calculations. In the case of an exemplary grid shell structure for a North American project, supplementary measurement studies were carried out on large samples, so-called mock-ups, to achieve a better understanding of the condensation behavior.
This paper compares the thermal calculations on critical details with the corresponding measurement studies and discusses reasons for differences and precision. In addition, relevant standards and guidelines for condensation risk assessments for Europe and North America are summarized and the measurement setup is outlined.

x
Europäische Bewertungsdokumente EAD als Basis für den Vertrieb in den USABauphysik1/202026Aktuell

Kurzfassung

Keine Kurzfassung verfügbar.

x
Gärtner, Gabriele; Menzel, FrankUntersuchung der Langzeitstabilität von Silica basiertem hydrophobem Superisolationsmaterial in BauanwendungenBauphysik1/202027-33Fachthemen

Kurzfassung

Um die Marktanforderung nach immer besserer Dämmleistung der Gebäudehülle zu erfüllen, wurden hocheffiziente Dämmmaterialien, auch bekannt unter dem Namen Superisolationsmaterial (Super Insulation Materials), entwickelt. Das sind Materialien mit einer bis zu 10-mal geringeren Wärmeleitfähigkeit von herkömmlichen Dämmstoffen. Allerdings sind diese Materialien teuer und ihre Lebensdauer bei wechselnden hygrothermischen Einflüssen noch nicht hinreichend untersucht, was bereits im internationalen Forschungsprojekt Annex 65 der Internationalen Energieagentur (IEA) beschrieben wurde.
Der Hydrophobierungsprozess an synthetischem amorphen Siliziumdioxid SAS ist jedoch seit Langem bekannt und wird zur Hydrophobierung von Pulvern in verschiedenen Industrieanwendungen eingesetzt. Deshalb war der erste Schritt in der vorliegenden Studie die Langzeitstabilität von hydrophoben Pulvern zu evaluieren, um dann die Langzeitstabilität entsprechend hydrophobierter Formkörper zu untersuchen und zu bewerten.

Investigation on for the long-term performance of hydrophobic silica-based advanced porous materials in building applications
To satisfy the new demand of more and more efficient thermal insulation for building envelope highly efficient insulation materials, known as super insulation materials (SIM), have been developed, with a thermal conductivity up to 10 times lower than common thermal insulation products. However, although they offer excellent insulation performance, these materials are expensive and there is a lack of information on their durability under different hygrothermal conditions, which is described and examined in general in IEA Annex 65.
The hydrophobation of synthetic amorphous silica (SAS) is long been known and is applied to powder for several technical applications. Therefore, the first step of the presented study was to show the long-term stability of hydrophobic powders to investigate and evaluate afterwards the long-term stability of the hydrophobized mold bodies.

x
Kah, Oliver; Bräunlich, Kristin; Hartmann, Thomas; Knaus, Christine; Broege, Martina; Bruns, AlfredBewertung von Küchen-Dunstabzugssystemen in energieeffizienten GebäudenBauphysik1/202034-44Berichte

Kurzfassung

Technische Entwicklungen im Gebäudebereich werden in jüngerer Vergangenheit maßgeblich durch höhere Komfortansprüche und Anforderungen an die Energieeffizienz bestimmt. Im Rahmen des vorgestellten Forschungsvorhabens wurde für Dunstabzugssysteme der energetische Einfluss in Wohngebäuden, die Wirksamkeit der Systeme in Bezug auf die Reduzierung von Küchendünsten sowie die Wechselwirkung mit dem Gebäude und anderen technischen Systemen untersucht.
Eine gute Erfassung der Küchendünste ist mitentscheidend für eine wirksame Reduzierung der Raumluftbelastung. Es konnte ein neues Verfahren zur qualitativen Bewertung der Wrasenerfassung erprobt werden. Die Ergebnisse deuten auf erhebliche Unterschiede zwischen den untersuchten Dunstabzugssystemen hin. Ferner zeigten Labormessungen, dass Umluft-Dunstabzugssysteme mit Geruchsfilter deutlich bzgl. Geruchsreduzierung differieren.
Abluft-Dunstabzugssysteme erzeugen einen Unterdruck in der Wohneinheit. Aufgrund der hohen Luftdichtheit von energieeffizienten Gebäuden können sich im Abluftbetrieb sicherheitsrelevante Unterdrücke in Wohnungen einstellen. Abhängig vom zulässigen Unterdruck werden geeignete Lösungen vorgestellt. Ferner verursachen Abluft-Dunstabzugssysteme zusätzliche Wärmeverluste, die bisher z. B. in Energiebilanzverfahren nicht berücksichtigt werden. Modellrechnungen zeigen, dass der zusätzliche Wärmeverlust bei energieeffizienten Gebäuden eine relevante Größenordnung erreichen kann.

Assessment of air-extraction and kitchen hoods with recirculating air operation in energy efficient buildings
Recently, technical advancements in the building sector have strongly focused on matters of comfort and energy efficiency. Within the scope of the research project, the study analysed the energetic influence of kitchen hoods on residential buildings, the effectiveness of these systems to reduce cooking fumes and their interactions with other technical systems and the building itself.
In order to effectively reduce air pollution, it is vital to capture cooking fumes efficiently. During this study, it was possible to try out a new method for the qualitative assessment of the fume capture process. The results show considerably differences between the examined air-extraction systems. Further laboratory measurements made clear that hoods with recirculating air operation and activated carbon filter differed vastly in their effectiveness of reducing odours.
Exhaust systems cause negative pressure in a housing unit. Because highly energy-efficient buildings are largely airtight, this underpressure can reach levels that threaten a building's secureness. Depending on the permitted levels, the study introduces different solutions. Moreover, exhaust systems cause further thermal losses that have not been included in the energy balance of a building. Model calculations show that these extra thermal losses can indeed make a sizeable impact.

x
Berichtigung zu: Ulrich; Kautsch, Peter: Ãœber die Notwendigkeit dreidimensionaler, hygrothermischer Simulationen. Bauphysik 41 (2019), Heft 6, S. 295-301. https://doi.org./10.1002/bapi.201900024.Bauphysik1/202044Aktuell

Kurzfassung

Keine Kurzfassung verfügbar.

x
Bauphysik Aktuell 1/2020Bauphysik1/202045-48Bauphysik Aktuell

Kurzfassung


Aktuell:
60 Jahre Bundesverband Bausysteme e. V.
Neue Praxishilfe Fehlerlichtbogen-Schutzeinrichtungen
Rechtsgutachten: Wie Daten aus Gebäuden und Quartieren verwendet werden können
Zulassungen im Volltext beim DIBt kostenlos
Denkmalschutzgerechte Sanierung einer historischen Klinik mit Holzfaser-Innendämmsystem

x