abo_giftabo_onlineabo_printabo_studentabo_testangle_leftangle_rightangle_right_filledarrow_big_downarrow_big_down_filledarrow_big_leftarrow_big_left_filledarrow_big_rightarrow_big_right_filledarrow_big_uparrow_big_up_filledarrow_dropdown_downarrow_dropdown_uparrow_small_leftarrow_small_left_filledarrow_small_rightarrow_small_right_filledarrow_stage_leftarrow_stage_left_filledarrow_stage_rightarrow_stage_right_filledcaret_downcaret_upcloseclose_thinclose_thin_filledcontactdownload_thickdownload_thick_filleddownload_thindownload_thin_filledebookeditelement_headlineelement_labelelement_relatedcontentlockmailminuspagepage_filledpagespages_filledphoneplusprintprint_filledquotationmarks_leftquotationmarks_rightsearchsendshareshare_filledshoppingcart_bigshoppingcart_big_filledshoppingcart_headershoppingcart_smallshoppingcart_small_filledsocial_facebooksocial_linkedinsocial_pinterest social_xsocial_xingsocial_youtubesocial_twitteruser_biguser_small

Artikeldatenbank

Filter zurücksetzen
  • Autor(en)

  • Sprache der Veröffentlichung

  • Erschienen

  • Rubrik

Zeitschriften-Selektion

  • Alle auswählenAlle abwählen
Autor(en)TitelZeitschriftAusgabeSeiteRubrik
Rug, W.; Gümmer, K.; Gehring, S.Schraubenpressklebung mit NagelschraubenBautechnik1/201033-43Fachthemen

Kurzfassung

Die Schraubenpressklebung ist eine Methode zum Herstellen tragfähiger geklebter Verbindungen, welche in der neuen überarbeiteten DIN 1052:2008, Abschnitt 14 geregelt ist. Bei der Anwendung dürfen jedoch ausschließlich selbstbohrende Schrauben mit Teil gewinde zum Aufbringen des nötigen Pressdrucks benutzt werden. Im Rahmen grundlegender Untersuchungen wurde die Nagelschraube als Alternative zur bisher geregelten Schraube geprüft. Für die insgesamt drei untersuchten Klebstoffe wurden Verklebungen zwischen Brettschichtholz und Vollholz, Sperrholz, sowie Furnierschichtholz untersucht. Zusammen wurden 932 Prüfkörper in Anlehnung an DIN EN 392:1996 auf deren Klebfugenfestigkeiten hin getestet.
Die Ergebnisse der Untersuchungen zeigen, dass mit Nagelschrauben hergestellte Klebungen hinreichende Festigkeiten erzielen, um eine Schrauben-Pressklebung nach DIN 1052:2008 herzustellen.

Screw-press-bonding with nail screws.
The screw-press-bonding is a method to manufacture glued wooden joints. This technology is regulated in the new revised standard DIN 1052:2008 (which is based on the Eurocode 5). In practice it is only allowed to use self-drilling screws with partial thread to generate the required (contact) pressure. Based on different experiments the nail screw was tested as an alternative method. Three adhesives in all were used to make bonding between glued-laminated timber (BSH) and solid wood (VH), plywood (SH) and also laminated veneer lumber (LVL). Altogether, there were tested 932 specimens on their bonding strength on the basis of DIN EN 392:1996.
The results of this experiments show that bonded joints, which were manufactured with nail screws, generate enough strength to make a screw-press-bonding on the basis of DIN 1052:2008.

x
Rug, W.100 Jahre Hetzer-PatentBautechnik8/2006533-540Fachthemen

Kurzfassung

Der Zimmermeister Otto Hetzer aus Weimar erhielt auf die Erfindung eines gebogenen Holzbauteils am 22. 06. 1906 ein Patent. Das gebogene Holzbauteil sollte aus zwei oder mehreren Langholzstäben bestehen, die durch Zwischenfügen eines Klebstoffes zu einem Bauteil verklebt waren. Das neue Konstruktionsprinzip hatte zahlreiche Vorteile wie z. B. die Herstellung beliebig geformter Tragwerke, die Unabhängigkeit vom aus dem Stamm gewinnbaren Holzquerschnitt und die Herstellung statisch günstiger Querschnitte. Dieses Patent hat den Holzbau in den letzten 100 Jahren grundlegend verändert.

x
Rug, W.17. Holzbauseminar in Dresden-HellerauBautechnik12/2002881-882Berichte

Kurzfassung

Keine Kurzfassung verfügbar.

x
Rug, W.Instandsetzung des Holztragwerks einer historischen GlashütteBautechnik8/1998559-565Fachthemen

Kurzfassung

Die Bautechnik der Erhaltung historischer Konstruktionen erfordert eine Auseinandersetzung mit der Geschichte eines Gebäudes, die stets einen Abriß der Kulturgeschichte des Menschen vermittelt. Der sorgfältige Umgang mit dieser Geschichte zeigt sich vor allem in einer substanzschonenden Erhaltung, die ohne eine genaue Bauzustandsanalyse nicht denkbar ist. Der Beitrag befaßt sich mit der Problematik der Bauzustandsanalyse, der Bewertung des Bauzustandes und der Instandsetzungsplanung der historischen Holzkonstruktionen eines über 120 Jahre ununterbrochen genutzten Gebäudes einer Glashütte. Die Bauzustandsanalyse ergab unterschiedliche Schädigungen der Holzbauteile durch langjährige thermische Beanspruchung und hohe Feuchte im Holz.

x
Rug, W.Internationale Holzbaukonferenz vom 28. - 31.10.1996 in New Orleans.Bautechnik3/1997198-201Berichte

Kurzfassung

Keine Kurzfassung verfügbar.

x
Rug, W.Verbunddecken aus Holz und Beton.Bautechnik7/1995454-459Fachthemen

Kurzfassung

Bei der Errichtung neuer Bauten lassen sich mit Holz-Beton-Verbundquerschnitten gerade bei hohen Lasten, wie z. B. im Brückenbau oder bei mehrgeschossigen Gebäuden mit hohen Deckenlasten, wirtschaftliche Effekte erzielen. Dabei hängt die Wirtschaftlichkeit wesentlich von der Steifigkeit der Verbindung, d. h. von der Sicherung der Verbundwirkung, zwischen den beiden Materialien ab, die entweder durch Kleben oder durch Einsatz mechanischer Teile wie Nägel oder Betonstahl erzeugt werden kann. Zugleich ergibt sich bei der Anwendung dieses Verbundprinzips eine Verbesserung des Schall- und Brandschutzes.

x
Rug, W.Innovationen im Holzbau - Die Hetzerbauweise (Teil 2).Bautechnik4/1995231-241Fachthemen

Kurzfassung

Im zweiten Teil des Aufsatzes (erster Teil H. 4/94) untersucht der Autor die zeitliche Entwicklung zwischen 1925 und 1945. Es entstanden in den zwanziger Jahren in Deutschland weitere innovative Holzbauweisen, die mit der Hetzerbauweise konkurrierten. Die Boomzeit der Anfangsjahre war damit in Deutschland oder der Schweiz vorbei. Dagegen begann man in anderen Ländern erst mit der Produktion von Hetzerkonstruktionen wie in Schweden oder den Vereinigten Staaten. Erst die Entwicklung der Kunstharzklebstoffe in den 30er Jahren löste eine intensive Entwicklung neuer Leimbauweisen im Holzbau aus, die den Übergang von der reinen Hetzerbauweise zur Holzleimbauweise markiert und in den rohstoffarmen Jahren des zweiten Weltkrieges zu neuen konstruktiven Dimensionen und Spannweiten führt.

x
Rug, W.Holzbau in den neuen Ländern.Bautechnik1/199569-72Berichte

Kurzfassung

Keine Kurzfassung verfügbar.

x
Rug, W.Innovationen im Holzbau - Die Hetzerbauweise.Bautechnik4/1994213-219Fachthemen

Kurzfassung

Die Hetzerbauweise, entwickelt anfangs unseres Jahrhunderts, eröffnete eine neue Ära im Holzbau. Otto Hetzer (1846-1911) erfand das Brettschichtholz. Der Autor berichtet über die Entwicklung der Hetzerbauweise und zeigt Beispiele ihrer Anwendung.

x
Rug, W.10. Holzbauseminar.Bautechnik2/1994117-119Berichte

Kurzfassung

Keine Kurzfassung verfügbar.

x
Rug, W.Holzbautagung '92 in Berlin.Bautechnik6/1993359Berichte

Kurzfassung

Keine Kurzfassung verfügbar.

x
Rug, W.Holzbautagung '92 in Magdeburg.Bautechnik4/1993211Berichte

Kurzfassung

Keine Kurzfassung verfügbar.

x
Rug, W.Internationale Holzbaukonferenz 1991.Bautechnik6/1992290Berichte

Kurzfassung

Keine Kurzfassung verfügbar.

x
Rug, W.24. Jahrestagung "Timber Structures".Bautechnik4/1992197Berichte

Kurzfassung

Keine Kurzfassung verfügbar.

x
Rug, W.9. Holzbauseminar.Bautechnik1/199250-51Berichte

Kurzfassung

Keine Kurzfassung verfügbar.

x
Rug, W.12. Holzbauseminar.Bautechnik1/199748-49Berichte

Kurzfassung

Keine Kurzfassung verfügbar.

x
Ruff, Daniel C.90 Jahre Stahlbau an der Versuchsanstalt in KarlsruheStahlbau8/2011554-560Fachthemen

Kurzfassung

Die Berufung von Prof. Dr.-Ing. Ernst Gaber an die Technische Hochschule Karlsruhe im Jahr 1921 markierte den Startschuss des “Prüfraum Gaber“, aus dem später die Versuchsanstalt für Stahl, Holz und Steine hervorging. Heute ist die Versuchsanstalt Teil des Karlsruher Instituts für Technologie (KIT) und besteht aus den Abteilungen Holzbau und Baukonstruktionen sowie Stahl- und Leichtbau. Im folgenden Beitrag wird auf die Geschichte dieser Einrichtung in Bezug auf den Fachbereich Stahlbau zurückgeblickt.

90 years Steel Construction at the research centre in Karlsruhe, Germany.
The appointment of Prof. Dr.-Ing. Ernst Gaber to the University of Technology at Karlsruhe in 1921 gave the go-ahead for the “Testing Room Gaber”, from which the Versuchsanstalt für Stahl, Holz und Steine (Research Centre for Steel, Timber and Masonry) developed later. Today, the research center is part of Karlsruher Instituts für Technologie (Karlsruhe Institute of Technology, KIT) consisting of the departments Wood Construction and Structural Design as well as of Steel and Lightweight Structures. In the following contribution it is looked back on the history of this institution related to Steel Construction.

x
Romani, M.Biegezugverstärkung von Brettschichtholz mit CFK- und AFK-LamellenBautechnik4/2002216-224Fachthemen

Kurzfassung

Das Ziel der dargestellten Untersuchung war, Angaben zum Trag- und Verformungsverhalten von Verbundträgern aus Brettschichtholz (BS-Holz) und unidirektional verstärkten Faserverbundkunststoffen (FVK) zu erhalten. Dazu wurden der Einfluß des Verstärkungsgrades, der geometrischen Anordnung der Verstärkung und der Einfluß von CFK-Lamellen und AFK-Lamellen genauer untersucht und verstärkte BS-Holz Träger unter praxisnahen Bedingungen hergestellt.

x
Rinke, Mario; Gianoli, AndreasGesteckt und gestapelt - Der Werkhof Andelfingen (CH) als moderner Industrie-StrickbauBautechnik11/2016839-843Berichte

Kurzfassung

Als Abstellhalle für Fahrzeuge und als überdachter Arbeits- und Lagerplatz entstand in Andelfingen (Kanton Zürich) 2015 ein neues Werkhofgebäude. Die Halle mit den Abmessungen von 16, 50 × 30 m2 und einer Höhe von etwa 8 m sollte aus Holz konstruiert werden. Einem Bausatz gleich, sind für Wand und Dach flächenartige Konstruktionselemente entwickelt worden, die Tragwerk und Hülle integral vereinen und darüber hinaus einfach und schnell montiert werden können. Denn moderne industrielle Herstellungsmethoden des Holzbaus ermöglichten die Erweiterung der Typologie des traditionellen Strickbaus auf den großmaßstäblichen Industriebau. Das Stapeln und Ineinanderstecken von etwa 2 m hohen Brettschichtholzträgern mit der Länge der ganzen Gebäudeseite, oben in die Wände eingesteckte Dachbinder und darauf aufgesetzte Mehrschichtplatten ermöglichte eine Holzkonstruktion mit nur wenigen zusätzlichen Verbindungsmitteln aus Stahl und eine Montagezeit des Holzbaus von nur 4 d. Durch enge Zusammenarbeit aller Planer vereinen sich Materialeigenschaften, Konstruktion, Tragwerk, Montageprinzip und architektonischer Ausdruck.

Plugged and stacked - the maintenance depot in Andelfingen (CH) as a modern industrial log construction
In 2015 a new maintenance depot for utility vehicles was built in Andelfingen (Canton Zurich). The building is 16.50 m wide and 30 m long with a height of 8 m and was supposed to be constructed in wood. Referring to the simpilicity of an assembly set, planar components have been developed for the roof and the walls integrating both the load bearing structure and the building envelope and allowing for a simple and fast assembly. This was possible because of modern industrial fabrication techniques which allow to transfer the traditional log construction to a large scale industrial building type. The process of stacking and plugging 2 m high laminated timber components with the length of the entire building, the slotting of the roof beams into the wall and the multilayer board on top rendered possible a timber building with only a few additional iron fasteners put together in only 4 d. Only through close cooperation of architects, engineers and contractors a strong relation of the building material, the construction principle, the building structure and its architectural expression is achieved.

x
Ringhofer, Andreas; Brandner, Reinhard; Schickhofer, GerhardEntwicklung einer optimierten Schraubengeometrie für hochbeanspruchte Stahl-Holz-VerbindungenBautechnik1/201431-37Aufsätze

Kurzfassung

Der Beitrag behandelt die Optimierung der Geometrie von vorwiegend axial beanspruchten selbstbohrenden Holzschrauben für den Einsatz in einer Stahl-Holz-Laschenverbindung unter Zug parallel zur Faser. Mit Fokus auf den Stahlbruch werden der Kopf und Ansatzbereich des Gewindes adaptiert und die Veränderungen im Last-Verformungsverhalten anhand von Prototypen versuchstechnisch an bauteilgroßen Laschenstößen und mittels einer numerischen Modellierung verifiziert. Es zeigen sich eine gegenüber herkömmlichen Schraubentypen um 2 bis 8 % gesteigerte Tragfähigkeit, eine Verlagerung des Versagens der Schraube von der Stahlblech-Unterkante tiefer in das Holz sowie die Ausbildung eines Fließgelenks am Beginn der geschaffenen Freistrecke. Letzteres lässt einerseits eine homogenere Lastverteilung zwischen den Schrauben infolge eines erheblich gesteigerten Duktilitätspotenzials und andererseits eine Verbesserung des Tragverhaltens solcher Anschlüsse bei Langzeit- und Zugschwellbelastungen erwarten. Zudem wird ein Vorschlag für den Nettoquerschnittsnachweis für zugbeanspruchte Laschenstöße mit selbstbohrenden Holzschrauben unterbreitet.

Development of an optimized screw geometry for high-stressed steel-to-timber joints
This paper deals with the geometrical optimization of mainly axially loaded self-tapping screws applied in steel-to-timber joints under tension parallel to grain. Focusing on steel failure, the head geometry and the zone before the thread were adapted. Consequently, differences to standard products were verified by laboratory tests on full-scale steel-to-timber joints and also by numerical modeling. A 2 to 8 % increase of load bearing resistance, a displacement of the location of screw failure deeper into the timber member as well as the development of a plastic hinge close to the head are the essential results of this study. Especially the yield deformation leads to a more homogenous load sharing between a group of screws, caused by an increased potential of ductility, and to an enhanced bearing behavior under long term as well as pulsating tensile loadings. In addition to that a proposal for the verification of the net cross-section of tensile joints with self-tapping screws is given.

x
Ringhofer, Andreas; Brandner, Reinhard; Flatscher, Georg; Schickhofer, GerhardAxial beanspruchte Holzschrauben in Vollholz, Brettschichtholz und BrettsperrholzBautechnik11/2015770-782Aufsätze

Kurzfassung

Dieser Fachaufsatz behandelt das Tragverhalten axial beanspruchter, selbstbohrender Holzschrauben in den geschichteten, brettbasierenden Holzwerkstoffen Brettschichtholz und Brettsperrholz bzw. in Vollholz. Mit Fokus auf den Versagensmechanismus “Herausziehen” wird auf Basis zahlreicher Untersuchungen in der Vergangenheit ein neues universelles Modell zur Bestimmung der Ausziehfestigkeit formuliert, welches mittels multiplikativem Ansatz eigens definierter k-Faktoren bzw. k-Funktionen in der Lage ist, die große Bandbreite an unterschiedlichen Einbausituationen in den betreffenden Holzwerkstoffen abzubilden. Eine Verifizierung dieses Modells erfolgt anschließend unter Zugrundelegung einer umfangreichen Sammlung an Prüfdaten, vergleichbarer Ansätze aus der Literatur und Prüfergebnissen von Schraubenverbindungen in Form von Brettsperrholz-Wand-Decken- bzw.-Wand-Wand-Anschlüssen. Abschließend wird ein Ansatz zur Bestimmung des charakteristischen Wertes der Ausziehfestigkeit für die Anwendung in der Praxis abgeleitet, diskutiert und erneut den Prüfergebnissen gegenübergestellt.

Axially loaded screws in solid timber, glued laminated timber and cross laminated timber
This paper concentrates on the bearing behavior of axially loaded self-tapping screws in solid timber and the board-composed, layered timber products glued laminated timber and cross laminated timber. Focusing on withdrawal failure mode and basing on numerous investigations done in the past, we formulate a new and universal approach including multiplicative k-factors or k-functions for determining the withdrawal strength of self-tapping screws variably situated in these products. Consequently, we verify the new model with results gained from several test series related, approaches given in the literature and test results of CLT-wall-to-floor and -wall-to-wall connections. Finally, we determine, discuss and verify a characteristic function provided for practical application.

x
Rieckmann, H-P.Knicklängen symmetrischer und asymmetrischer verschieblicher Kehlbalkendächer.Bautechnik3/198397-100

Kurzfassung

Anhand von Versuchsauswertungen und dem analytischen Lösungsweg werden Knicklängenbeiwerte der Stabelemente von Kehlbalkendächern angegeben.

x
Reyer, E.; Gnuschke, M.Zum Einfluß von Ästen auf die Tragfähigkeit von Zugstößen und -anschlüssen mit Stabdübeln.Bautechnik12/1993747-754Fachthemen

Kurzfassung

Nach kurzer einführender Beschreibung der Vorzüge und Besonderheiten von Stabdübelverbindungen wird die Zielsetzung der vorliegenden Arbeit beschrieben: Ermittlung des Einflusses von Ast- und Kerbwirkung auf die Tragfähigkeit von Zugstößen und -anschlüssen mit Stabdübeln und Erarbeitung entsprechender Bemessungsvorschläge. Als Ergebnis der Untersuchung werden in Abschnitt 5 einfache Bemessungsempfehlungen für Stabdübelverbindungen unter Zugbeanspruchung angegeben. Daraus geht hervor, daß bei Brutto-Querschnittsflächen des einzelnen Holzes mit A >= 100 cm2 Äste im Bereich der Stabdübelverbindungen bei der Bemessung nicht berücksichtigt zu werden brauchen. Wenn Äste bzw. Astgruppen im Bereich der ersten Stabdübelebene nicht ausgeschlossen werden können und die Brutto-Querschnittsfläche A des Einzelholzes kleiner als 100cm2 ist, sollte die zulässige Zugspannung bei Stoß und Anschlußteilen entweder mit dem angegebenen Faktor a = a(A) nach Gleichung (6) - oder, vereinfachend pauschal um 20% abgemindert werden.

x
Reyer, E.; Benning, H.-H.Zur optimalen Bemessung kippgefährdeter Brettschichtholzträger unter Gebrauchslasten und unter Brandbeanspruchung.Bautechnik3/199185-92

Kurzfassung

Querschnittsreduzierung und Veränderung der mechanischen Eigenschaften unter Brandbeanspruchung. Erarbeitung von Bessungshilfen für kippgefährdete Brettschichtholzträger unter Gebrauchslast und im Brandfall.

x
Rehm, Jörg; Barthel, Rainer; Maus, HelmutInstandhaltung und statische Sicherung der Stadtpfarrkirche von Pfaffenhofen an der IlmBautechnik5/2012354-360Berichte

Kurzfassung

Über dem Hauptschiff der Stadtpfarrkirche St. Johannes Baptist in Pfaffenhofen an der Ilm befindet sich ein über 520 Jahre altes Dachwerk. Das Sparrendach mit zweifach stehendem Stuhl entstand im Zuge des spätgotischen Ausbaus der Kirche am Ende des 15. Jahrhunderts und wurde bei der Erweiterung der Kirche um 1910 nach Westen ergänzt. Der Dachstuhl über dem Chorbereich wurde bereits vor 1900 erneuert. Durch Feuchteeinwirkung im Bereich der Fußpunkte war der älteste Teil des Dachstuhls in seiner Tragfähigkeit stark beeinträchtigt. Weiterhin wurden Verformungen und komplexe Rissbilder an den aufgehenden Wänden und den Gewölben festgestellt, die in einer sorgfältigen Schadensaufnahme dokumentiert wurden. Der Kirchenraum mit seiner frühbarocken Stuckausstattung stellte hohe Anforderungen an das Instandsetzungskonzept, bei dem es gleichermaßen um die Behebung lokaler Schädigungen wie um die Sicherung der aufgehenden Wände im Ganzen ging. Alle Maßnahmen konnten mit dem Ziel der größtmöglichen Erhaltung historischer Substanz geplant und ausgeführt werden. In einem weiteren Bauabschnitt ist noch die Teilunterfangung des Chores vorgesehen. Erst nach dieser Maßnahme wird die Innenrestaurierung in Angriff genommen.

Repair and static saving of the main church of Pfaffenhofen/Ilm, Germany
The main nave of St. Johannes Baptist in Pfaffenhofen a. d. Ilm still possesses its historic roof structure from the late 15th century. The couple roof with its main trusses was erected during the building's late gothic extension. its western part as added in 1910 after the historic model; the roof above the sanctuary was rebuild in around 1900. A series of damage made a thorough restoration of the church inevitable: the roof trusses' base joints were decayed, and the walls and vaults showed cracks and deformations. In a thorough survey, the damage was systematically recorded and its causes analyzed. The preservation of the church's valuable interior its 17th century stucco made special care during the restoration necessary: all measures were planned and carried out with a special focus on the conservation of historic substance. The underpinning of the sanctuary will follow in the next construction phase; the restoration of the interior is intended as the final step.

x