abo_giftabo_onlineabo_printabo_studentabo_testangle_leftangle_rightangle_right_filledarrow_big_downarrow_big_down_filledarrow_big_leftarrow_big_left_filledarrow_big_rightarrow_big_right_filledarrow_big_uparrow_big_up_filledarrow_dropdown_downarrow_dropdown_uparrow_small_leftarrow_small_left_filledarrow_small_rightarrow_small_right_filledarrow_stage_leftarrow_stage_left_filledarrow_stage_rightarrow_stage_right_filledcaret_downcaret_upcloseclose_thinclose_thin_filledcontactdownload_thickdownload_thick_filleddownload_thindownload_thin_filledebookeditelement_headlineelement_labelelement_relatedcontentlockmailminuspagepage_filledpagespages_filledphoneplusprintprint_filledquotationmarks_leftquotationmarks_rightsearchsendshareshare_filledshoppingcart_bigshoppingcart_big_filledshoppingcart_headershoppingcart_smallshoppingcart_small_filledsocial_facebooksocial_linkedinsocial_pinterest social_xsocial_xingsocial_youtubesocial_twitteruser_biguser_small

Artikeldatenbank

Filter zurücksetzen
  • Autor(en)

  • Sprache der Veröffentlichung

  • Erschienen

  • Rubrik

Zeitschriften-Selektion

  • Alle auswählenAlle abwählen
Autor(en)TitelZeitschriftAusgabeSeiteRubrik
Roos, E.Zur Berechnung vorgebeulter Kugelschalen unter gleichmäßigem Außendruck.Stahlbau2/197133-44Fachthemen

Kurzfassung

Keine Kurzfassung verfügbar.

x
Schönbach, W.Als Netzkuppel ausgebildetes Radom mit 49 m Durchmesser.Stahlbau2/197145-55Fachthemen

Kurzfassung

Keine Kurzfassung verfügbar.

x
Rosemeier, G.-E.Aeroelastische Probleme des Bauwesens.Stahlbau2/197155-58Fachthemen

Kurzfassung

Keine Kurzfassung verfügbar.

x
Rudolphi, R.; Knoblauch, E.Ein Rechenverfahren zur Auswertung von Brandversuchen an Stahlbauteilen.Stahlbau2/197159Berichte

Kurzfassung

Keine Kurzfassung verfügbar.

x
Schröter, H.-J.Projekt einer Brücke über die Meerenge von Messina.Stahlbau2/197160-64Berichte

Kurzfassung

Keine Kurzfassung verfügbar.

x
Lacher, G.Drei durchgehend geschweißte Eisenbahnbrücken von je 100 m Länge.Stahlbau1/19711-5Fachthemen

Kurzfassung

Keine Kurzfassung verfügbar.

x
Schardt, R.; Okur, H.Hilfswerte für die Lösung der Differentialgleichung ayIV(x)-by''(x)+cy(x)=p(x).Stahlbau1/19716-17Fachthemen

Kurzfassung

Keine Kurzfassung verfügbar.

x
Hildenbrand, P.Vergleich zweier Wege zur Ermittlung der Kippstabilität gerader gabelgelagerter Einfeldträger mit doppelt-symmetrischem I-Querschnitt nach der Energiemethode.Stahlbau1/197118-23Fachthemen

Kurzfassung

Keine Kurzfassung verfügbar.

x
Hye, P.Hängekrananlage in der neuen Wartungshalle V der Deutschen Lufthansa AG am Flughafen Frankfurt /Main.Stahlbau1/197124-26Fachthemen

Kurzfassung

Keine Kurzfassung verfügbar.

x
Radaj, D.Dünnwandige Stäbe und Stabsysteme mit allgemeiner Systemlinie und wölbelastischer Lagerung.Stahlbau1/197127-31Berichte

Kurzfassung

Keine Kurzfassung verfügbar.

x
Schneider, MaxHochhäuser mit hängenden GeschossenStahlbau2/196833-44Fachthemen

Kurzfassung

Keine Kurzfassung verfügbar.

x
Herber, K.-H.Vorschlag von Berechnungsgrundlagen für Beul- und Traglasten von SchalenStahlbau5/1966142-151Fachthemen

Kurzfassung

Keine Kurzfassung verfügbar.

x
Tussing, F.Die Stahlüberbauten der Berliner Brücke im Zuge der Stadtautobahn DuisburgStahlbau5/1964152-157Fachthemen

Kurzfassung

Keine Kurzfassung verfügbar.

x
Schmeer, H.; Heinzel, W.Die Autobahnbrücke über das Fechingertal bei SaarbrückenStahlbau4/196497-108Fachthemen

Kurzfassung

Keine Kurzfassung verfügbar.

x
Henzen, WernerDas Stahlskelett des Verwaltungshochhauses W 1 der Farbenfabriken Bayer AG. in LeverkusenStahlbau1/19647-14Fachthemen

Kurzfassung

Das Hochhaus W 1 liegt auf dem früheren Gelände des japanischen Gartens der Farbenfabriken Bayer AG. Ein umfangreiches und vielseitiges Bau- und Raumprogramm fand mit der Errichtung dieses Gebäudes eine repräsentative Lösung. Das Bauwerk hat eine Höhe von 120,6 m und besteht aus dem Erdgeschoß, Zwischengeschoß und 31 Obergeschossen, dem Dach als 32. Geschoß, sowie drei Kellergeschossen. Die Breite des Gebäudes beträgt 19,33 m (oder 20,06 m bis Außenkanten der Stützen), seine Länge 65,43 m.

x
Naudascher, EduardBerechnung der dynamischen Kräfte bei TiefschützenStahlbau3/195957-68Fachthemen

Kurzfassung

Keine Kurzfassung verfügbar.

x
Überschlägliche Ermittlung der Spannungserhöhung für stählerne Bogen nach Theorie II. OrdnungStahlbau2/195643Rubriken

Kurzfassung

Keine Kurzfassung verfügbar.

x
Sahmel, P.Näherungsweise Berechnung der Knicklängen von StockwerkrahmenStahlbau4/195589-94Fachthemen

Kurzfassung

Einfache Näherungsformeln zur praktischen Berechnung der Knicklängen von Stockwerkrahmen.

x
Content: Steel Construction 2/2023Steel Construction2/2023Contents

Kurzfassung

Keine Kurzfassung verfügbar.

x
Cover Picture: Steel Construction 2/2023Steel Construction2/2023Cover Pictures

Kurzfassung

Stub column compression test of a cold-formed C-shaped steel-section used for the validation of a new design approach which combines the AISI S100-16 Direct Strength Method with EN 1993-1-3. Failure mode of the test specimen: distortional buckling (s. paper: Ungermann, D.; Lemaski, T.; Brune, B., pp. 78-92). Copyright: TU Dortmund Lehrstuhl Stahlbau

x
Martins, André Dias; Camotim, Dinar; Dinis, Pedro Borges; Chen, Man-Tai; Young, BenLocal-distortional interaction in cold-formed steel lipped channel beams: Experimental investigation - Nominee Professor Eduardo de Arantes e Oliveira Award 2021Steel Construction2/202368-77Articles

Kurzfassung

This paper reports an experimental investigation on the behaviour and strength of cold-formed high-strength steel (G450-G500) lipped channel beams susceptible to local-distortional interaction. The experimental campaign comprised 36 tests involving simply supported beams bent about the major axis, exhibiting various ratios between their distortional and local critical buckling moments (from 1.09 to 1.46) and acted by either uniform (20 tests) or non-uniform (trapezoidal: 16 tests) bending diagrams. The results presented and discussed consist of equilibrium paths, photos providing the evolution of the beam deformed configurations and failure moments. The paper also includes a few remarks on the design, using the Direct Strength Method, of the beams under consideration.

x
Ungermann, Dieter; Lema ski, Tim; Brune, BettinaA Eurocode-compliant design approach for cold-formed steel sectionsSteel Construction2/202378-92Articles

Kurzfassung

A Eurocode-compliant design approach was developed for the design of thin-walled cold-formed steel sections which combines the AISI S100-16-Direct Strength Method (DSM) with the design provisions of EN 1993-1-3. The new design approach transfers the cross-sectional resistance determined acc. to DSM based on numerical elastic buckling analyses on the gross cross-section into the global member verification acc. to EN 1993-1-3. Additional factors were introduced to optimize the new approach, e.g., to account for the effects of the nonlinear stress distribution in cross-sections subject to local and/or distortional buckling. Within the framework of the German research project FOSTA P1328/IGF 19964, an extensive series of tests on differently shaped, perforated, and unperforated cold-formed sections in compression and bending were conducted which serve to analyze the buckling phenomena and the load-bearing capacity and to validate the new design approach. In addition, a numerical model was developed, calibrated to the tests, and used for further parametric analyses on the load-bearing capacity of cold-formed sections.

x
Nonn, Jonas; Wilden, Vera; Feldmann, MarkusA consistent approach for global buckling of steel structuresSteel Construction2/202393-104Articles

Kurzfassung

The “General Method” according to chapter 6.3.4 of EN1993-1-1 or 8.3.4 of prEN1993-1-1 deals with the verification of stability problems of frame and beam structures with loadings in-plane. The “General method” according to Eurocode is intended for the general case of a combined moment and normal force. For the choice of the reduction factor &khgr;op, there are two options for applying the reduction curve, either the minimum of lateral torsional buckling (LTB) and flexural buckling (FB) or a weighted combination of both. With the use of analytical derivations, it can be shown that this approach leads to inconsistencies which can possibly lead to incorrect results. In this paper an alternative approach is presented which leads to unification and fully mechanical justification in verification. The approach allows e.g. the verification of stability of an entire frame system directly and without interaction factors (as in the equivalent member method). In addition, the issue of a consistent equivalent imperfection is addressed. With the use of this method, geometrical non-linear analyses of structures showing out-of-plane instability can be omitted; only an in-plane calculation and a determination of a linear buckling analysis is necessary. Finally, examples are presented in this paper that demonstrate the application of the approach shown.

x
Pham, Ngoc HieuInvestigation of sectional capacities of cold-formed perforated steel channel sectionsSteel Construction2/2023105-113Articles

Kurzfassung

Web holes are commonly seen in cold-formed steel channel sections to accommodate the technical services. The presence of the web holes has resulted in the reduction of the sectional capacities of the cold-formed steel sections and has been considered in the design according to the American Specification AISI S100-16 using a new approach in the design called the Direct Strength Method (DSM). This article, therefore, will use this design method to investigate the sectional capacities of perforated channel sections under compression or bending with the variation of hole sizes in relation to those of gross channel sections. Elastic buckling analysis - a compulsory requirement for application of the DSM - can be conducted using a module CUFSM software program recently developed by the American Iron and Steel Institute. The investigated channel sections are taken from the availably commercial sections. The obtained sectional capacities are seen as the opposite trends for local and distortional buckling modes, although a downtrend of the sectional capacities is found in general with the increase of hole dimensions. It was found that perforated channel sections with smaller hole height and longer hole lengths were recommended to obtain the optimum section capacities in terms of the same web hole area, but the opposite trend was seen for these sections under bending with long hole lengths.

x
Buchholz, Aljoscha; Seidel, MarcGap height prediction for bolted ring flange connections based on measurementsSteel Construction2/2023114-126Articles

Kurzfassung

Wind turbine towers and their flange connections are highly fatigue loaded structures. Previous investigations have shown that initial parallel gaps between L-flange connections, which are resulting from their respective flatness of the contact surfaces, can increase fatigue loads of the connecting fasteners significantly. Flange flatness and/or gap sizes in between flanges must comply with limitations given in relevant standards and therefore must be measured after the manufacturing process and/or during installation. More than 1900 flatness measurements of several offshore wind projects were collected and used to determine initial gaps between flanges analytically. A statistical evaluation allows to determine the distribution of expected gap sizes. The increase of gap height with increasing gap length can be described with linear correlations. Furthermore, the distributions of gap heights are approximated with log-normal distributions. Parameters for generic log-normal distributions are derived considering all performed mating simulations. Following the described methodology, gaps can be determined from any large number of flatness measurements. It is proposed to consider the results for flange design.

x