abo_giftabo_onlineabo_printabo_studentabo_testangle_leftangle_rightangle_right_filledarrow_big_downarrow_big_down_filledarrow_big_leftarrow_big_left_filledarrow_big_rightarrow_big_right_filledarrow_big_uparrow_big_up_filledarrow_dropdown_downarrow_dropdown_uparrow_small_leftarrow_small_left_filledarrow_small_rightarrow_small_right_filledarrow_stage_leftarrow_stage_left_filledarrow_stage_rightarrow_stage_right_filledcaret_downcaret_upcloseclose_thinclose_thin_filledcontactdownload_thickdownload_thick_filleddownload_thindownload_thin_filledebookeditelement_headlineelement_labelelement_relatedcontentlockmailminuspagepage_filledpagespages_filledphoneplusprintprint_filledquotationmarks_leftquotationmarks_rightsearchsendshareshare_filledshoppingcart_bigshoppingcart_big_filledshoppingcart_headershoppingcart_smallshoppingcart_small_filledsocial_facebooksocial_googleplussocial_linkedinsocial_pinterestsocial_twittersocial_xingsocial_youtubeuser_biguser_small

Artikeldatenbank

Filter zurücksetzen
  • Autor(en)

  • Sprache der Veröffentlichung

  • Erschienen

  • Rubrik

Zeitschriften-Selektion

  • Alle auswählenAlle abwählen
Autor(en)TitelZeitschriftAusgabeSeiteRubrik
Schädlich, Bert; Schweiger, Helmut F.Modelling the shear strength of overconsolidated clays with a Hvorslev surfacegeotechnik1/201447-56Fachthemen

Kurzfassung

The modelling of highly overconsolidated clays with a so-called Hvorslev yield surface is discussed in this paper. After a brief review of the mechanical behaviour of clays, the mathematical relationships of the Hvorslev surface based on critical state soil mechanics are presented. The Hvorslev surface is implemented in a multilaminate constitutive model; hence, an introduction to this type of model is provided. The model is validated by comparing model predictions with the experimental undrained stress paths, peak shear strengths and excess pore pressures of two overconsolidated clays.

Zur Modellierung der Scherfestigkeit von überkonsolidierten Tonböden mit einer Hvorslev-Fließfläche
Dieser Beitrag behandelt die Modellierung des Verhaltens von stark überkonsolidierten Tonböden mit einer sogenannten Hvorslev-Fließfläche. Nach einem kurzen Überblick über das mechanische Verhalten dieser Böden werden die mathematischen Zusammenhänge zur Beschreibung der Hvorslev-Fließfläche auf der Basis von Critical State Soil Mechanics erläutert. Die Hvorslev-Fließfläche wurde in einem multilaminaten Stoffmodell implementiert, weshalb die Grundzüge dieses Modelltyps vorgestellt werden. Das Modell wird validiert durch den Vergleich mit experimentell ermittelten undrainierten Spannungspfaden, maximalen Scherfestigkeiten und Porenwasserdruckentwicklungen von zwei überkonsoliderten Tonböden.

x
DGGT-Mitteilungen 1/2014geotechnik1/201457-59DGGT-Mitteilungen

Kurzfassung

10th International Conference on Geosynthetics und 33. Baugrundtagung 2014 in Berlin
Fachsektion Bodenmechanik: Wahl der Fachsektionsleitung / Fachsektion Erd- und Grundbau: Wahl der Fachsektionsleitung / Fachsektion Felsmechanik: 21. Symposium für Felsmechanik und Tunnelbau 2014 / Fachsektion Kunststoffe in der Geotechnik: Wahl der Fachsektionsleitung / Aktivitäten von DGGT-Mitgliedern zur Nachwuchsförderung: Förderung studentischer Mitgliedschaften / ISSMGE International Society for Soil Mechanics and Geotechnical Engineering: ISSMGE Bulletin; ISSMGE - Student and Young Members Presidential Group (SYMPG) / IAEG International Association for Engineering Geology and the Environment: IAEG Newsletter / IGS International Geosynthetics Society: IGS News (Dr. Kirsten Laackmann)
Aus der DGGT-Nachwuchsförderung: Aktivitäten der Arbeitsgruppe zur Nachwuchsförderung in der DGGT auf der 33. Baugrundtagung 2014 (Dipl.-Ing. Julian Sprengel, Regionalbeauftragter West)

x
Persönliches: geotechnik 1/2014geotechnik1/201459-64Persönliches

Kurzfassung

Prof. Dr.-Ing. Christoph Heckötter verstarb im Alter von 66 Jahren (Ferdinand Stölben, Richard A. Herrmann)
Anton Weißenbach 85 Jahre (Achim Hettler)
Eine 100-Jahr-Feier mit Victor Rizkallah und seiner Stiftung (Prof. Dr.-Ing. Martin Achmus)
Prof. Dr.-Ing. Georg Heerten 65 Jahre (Prof. Dr.-Ing. Karl Josef Witt)
Professor Dr.-Ing. habil. Theodoros Triantafyllidis wurde 60 (Prof. Dr.-Ing. habil. Christos Vrettos)
Professor Dr.-Ing. Martin Ziegler 60 Jahre (Georg Heerten, Karl Josef Witt, Benjamin Aulbach)

x
CBTR-Nachrichten: geotechnik 1/2014geotechnik1/201464-66CBTR-Nachrichten

Kurzfassung

Nächste CBTR-Tagung 2015 in Wien
VOB-C-Kommentar erscheint mit CBTR-Beteiligung
Das aktuelle Urteil: BGH: “Der Sachverständige muss gehört werden!”; Bauprozess - eine unendliche Geschichte?; “Anerkannte Regeln der Technik” nicht nur in Schriftform (Dr. jur. Günther Schalk, Fachanwalt für Bau- und Architektenrecht, Lehrbeauftragter für Bau-, Vergabe- und Architektenrecht; Dipl.-Jur. Florian Englert)

x
Dissertationen: geotechnik 1/2014geotechnik1/201466-72Dissertationen

Kurzfassung

Keine Kurzfassung verfügbar.

x
geotechnik aktuell 1/2014geotechnik1/201472-76geotechnik aktuell

Kurzfassung

HTG-Kongress und 100-Jahrfeier in Berlin
HTG: 100-Jahrfeier in Berlin vom 21. bis 23. Mai 2014
13. Altbergbau-Kolloquium an der TU Bergakademie Freiberg (Dr.-Ing. Günter Meier, Obmann des Arbeitskreises 4.6 “Altbergbau”)
9. Hans Lorenz Symposium an der Technischen Universität Berlin (Univ.-Prof. Dr.-Ing. habil. Christian Moormann, Stuttgart)

x
Firmen und Verbände: geotechnik 1/2014geotechnik1/201476Firmen und Verbände

Kurzfassung

STRABAG AG übernimmt Straßen- und Tiefbau-Aktivitäten der Johann Kipp Bauunternehmen GmbH
Stahlfundamente für Offshore-Windkraftanlagen: Bilfinger investiert in eigene Produktionskapazitäten

x
Termine: geotechnik 1/2014geotechnik1/201477-78Termine

Kurzfassung

Keine Kurzfassung verfügbar.

x
Jahresinhaltsverzeichnis 2013Mauerwerk1/20141-8Jahresinhaltsverzeichnis

Kurzfassung

Keine Kurzfassung verfügbar.

x
Inhalt: Mauerwerk 1/2014Mauerwerk1/2014Inhalt

Kurzfassung

Keine Kurzfassung verfügbar.

x
Brameshuber, WolfgangNicht genormtes Architekturmauerwerk, Rationalisierung und 9/11Mauerwerk1/20141Editorial

Kurzfassung

Keine Kurzfassung verfügbar.

x
Brameshuber, Wolfgang; Graubohm, MarkusNeues Mörtelsystem für Dünnbettmauerwerk - "Mörtelband"Mauerwerk1/20142-14Fachthemen

Kurzfassung

Vorgestellt wird eine Neuentwicklung im Bereich der Dünnbettmörtel. Es handelt sich hierbei um ein Mörtelband, das im trockenen Zustand auf die Lagerfugenfläche von Planhochlochziegeln aufgelegt und im Anschluss mit einer festgelegten Menge Wasser aktiviert wird. Das Mörtelband besteht aus einem Glasfasergewebe und Trockenmörtel, welcher durch einen wasserlöslichen Schmelzkleber zusammengehalten wird. Das in die Mörtelplatten eingelegte Gewebe dient dabei lediglich einer erhöhten Stabilität der Mörtelplatten beim Vermauern. In diesem Artikel werden zunächst die im Rahmen des Zulassungsverfahrens durchgeführten Untersuchungen beschrieben. Weiterhin wird die Vorgehensweise bei einer Zustimmung im Einzelfall anhand eines Praxisbeispiels aufgezeigt, bei dem das Mörtelband bereits zum Einsatz gekommen ist.

New mortar system for thin layer mortar masonry - “mortar pad”. A new development in the field of thin layer mortars is presented.
This is a mortar pad which is placed in the dry state on the bed joint area of high precision hollow clay units and which is subsequently activated with a defined amount of water. The mortar pad consists of a fibre glass reinforcement and dry mortar which is kept together by a water-soluble hot melt adhesive. The fabric placed in the mortar pads only serves to increase the stability of the mortar pads while laying on the units. In this paper, at first the examinations carried out within the framework of the approval procedure are described. Moreover, it is shown how an approval in the individual case is obtained using a practical example where the mortar pad has already been used.

x
Fernlehrgang zum "Energieberater TU Darmstadt" und "Fachplaner TU Darmstadt"Mauerwerk1/201414Aus der Lehre

Kurzfassung

Keine Kurzfassung verfügbar.

x
Brameshuber, Wolfgang; Graubohm, MarkusFormfaktoren für MauersteineMauerwerk1/201415-26Fachthemen

Kurzfassung

Bei der Druckfestigkeitsprüfung von Mauersteinen ist die Höhe des Prüfwertes von verschiedenen Faktoren abhängig. So kann u. a. die während der Druckbelastung hervorgerufene Querdehnungsbehinderung den Prüfwert der Druckfestigkeit deutlich beeinflussen. Wie groß dieser Einfluss ist, hängt im Wesentlichen von der Schlankheit der Mauersteine ab. Mit abnehmender Schlankheit vergrößert sich der Prüfwert der Druckfestigkeit durch den Einfluss der Querdehnungsbehinderung. Bei gleichem Mauersteinmaterial ergeben sich somit für Mauersteine mit geringer Schlankheit deutlich höhere Druckfestigkeitswerte als für Mauersteine mit größerer Schlankheit. Als weitere Einflussfaktoren können der Feuchtegehalt und das Größenformat der Prüfkörper genannt werden. Ziel einer am Institut für Bauforschung (ibac) der RWTH Aachen University durchgeführten Forschungsarbeit war die voneinander losgelöste Herleitung von differenzierten Formfaktoren für die zuvor genannten Einflussfaktoren. Untersucht wurden Prüfkörper mit unterschiedlichen Schlankheiten, Feuchtegehalten und Formaten, die aus Porenbeton-Planelementen der Festigkeitsklassen 2 und 6 sowie Kalksandstein-Planelementen der Festigkeitsklasse 20 entnommen wurden. Die Ergebnisse dieser Untersuchungen werden im vorliegenden Artikel vorgestellt.

Shape factors for masonry units.
In compressive tests on masonry units, the height of the test value depends on different factors. Among others, the effect of platen restraint occurring during compression may exert a significant influence on the test value of the compressive strength. The extent of this influence mainly depends on the slenderness of the masonry units. The test value of the compressive strength increases with decreasing slenderness due to the influence exerted by the effect of platen restraint. Thus, when the masonry units are made of the same material, masonry units with a low slenderness yield significantly higher compressive strength values than masonry units with a high slenderness. Further influencing factors are the moisture content and the dimensions of the test specimens. It was the aim of a research project conducted at the Institute of Building Materials research (ibac) of RWTH Aachen University to separately derive defined shape factors for the previously mentioned influencing factors. Test specimens with different ratios of slenderness, moisture contents and dimensions which were taken from autoclaved aerated concrete high precision elements of strength classes 2 and 6 as well as from calcium silicate high precision elements of strength class 20 were examined. The results of these investigations are presented in the present paper.

x
KLB-Fachforum - die Zukunft des Bauens aus ExpertensichtMauerwerk1/201426Veranstaltungen

Kurzfassung

Keine Kurzfassung verfügbar.

x
Prengel, Jon; Andres, Matthias; Medzech, JürgenParkhaus Jahrhunderthalle Bochum - eine perforierte Mauerwerksfassade für den Industriepark WestMauerwerk1/201427-30Fachthemen

Kurzfassung

Aufgrund seiner geringen baulichen Höhe fügt sich das neue Parkhaus wie selbstverständlich in die Umgebung ein und führt das Westpark Konzept des “Grünen Rahmens“ sinnvoll weiter. Das Gebäude ist parallel zur ThyssenKrupp-Halle ausgerichtet: Nach Osten, Süden und Westen zeigt es ein städtisches Gesicht mit einer perforierten Fassade aus schwarz-grau-roten Kohlebrandziegeln, im Norden geht die begrünte Dachlandschaft symbolisch in die Böschung der Auffahrtsstraße über. Die für diesen Ort identitätsstiftenden Gebäude - das “Colosseum“, der Wasserturm und die Jahrhunderthalle - bleiben aus allen wichtigen Blickrichtungen unverstellt. Zwei getrennte Bewegungsabläufe für Autofahrer und Fußgänger ermöglichen eine schnelle Orientierung und kurze, sichere Wege innerhalb des Leitsystems.

Multi-storey car park “Century hall” Bochum - a perforated masonry façade for the industrial area “Industriepark West”.
The new multi-storey car park integrates well and self-understanding into the surrounding, because the height is quite small, and the architectural concept of Westpark, the so-called “green frame” is fulfilled perfectly. The building is oriented parallel to the “Thyssen-Krupp-Hall”, means it faces to east, south and west as like the town itself showing a perforated façade consisting of black-grey-red sintered coal bricks, and to north the green roof scenery symbolically migrates to the acclivity of the driving ramp. The dominating buildings in this area - “Colosseum”, water tower and the century hall - are still visible from each viewing direction. Two separate moving systems allow a very simple orientation for car-drivers and pedestrians as well and assure a short and safe moving within the guidance system.

x
Broschüre "Praxistipps für die Ausführung von Mauerwerk"Mauerwerk1/201430Fachliteratur

Kurzfassung

Keine Kurzfassung verfügbar.

x
Brameshuber, Wolfgang; Saenger, DorotheaZustimmungsverfahren einer gelochten Parkhausfassade aus KlinkernMauerwerk1/201431-44Fachthemen

Kurzfassung

Die Fassade des im Jahr 2013 neu erbauten Parkhauses Westpark an der Jahrhunderthalle in Bochum besteht aus einer gelochten, an einer Stahlkonstruktion rückverankerten Vorsatzschale aus Klinkern. Die offene Bauweise der Fassade erforderte eine Zustimmung im Einzelfall, da die Konstruktion nicht normgerecht ist. Anhand dieses Bauobjektes wird im Beitrag das Verfahren zur Erlangung einer Zustimmung im Einzelfall erläutert. Zum einen wird auf die durchgeführten experimentellen Untersuchungen und die daraus abgeleiteten Materialkennwerte, die für die Bemessung der Fassade erforderlich waren, eingegangen. Zum anderen wird die Überwachung der Ausführungsqualität des Mauerwerks auf der Baustelle aufgezeigt.

Approval process of a perforated clinker car park façade.
The façade of the in 2013 newly constructed car park Westpark at the Jahrhunderthalle in Bochum consists of a perforated facing made of clinkers, which is back-anchored to a steel structure. The open design of the façade required an approval in individual cases, because of its non-standard design. On the basis of this building project, the process for obtaining an approval in individual cases is explained in the article. On the one hand, the performed experimental studies and the derived material parameters, that were required for the design of the façade, are presented. On the other hand, the monitoring of the quality of execution of the masonry on site is shown.

x
Biggs, David T.From disaster to present day: the resiliency of masonry following September 11, 2001Mauerwerk1/201445-51Bericht

Kurzfassung

Terrorist attacks on September 11, 2001 in both New York City and Washington D.C. in the United States destroyed two 110-story office towers and a third 47-story office building at the World Trade Center (WTC) in New York and portions of the Pentagon in Washington D.C. All WTC buildings in the plaza area (Fig. 1, blue area) were destroyed that day as well.
The towers essentially had no masonry components. However, many of the surrounding buildings were impacted by the collapses but survived in some part, due to the masonry used in their construction. In Washington, the area of the masonry clad-Pentagon damaged on September 11 had been partially strengthened prior to the attack and was subsequently rebuilt.
Over the past decade, New York has worked to rebuild the World Trade Center area. This paper provides an update and acknowledges the resiliency of the masonry buildings in the aftermath of a major disaster. Some of the 2013 photographs are taken from a different vantage point from the 2001 photographs due to the construction that has taken place.

Von der Katastrophe bis zum heutigen Tag: Die Widerstandsfähigkeit von Mauerwerk, veranschaulicht an den Auswirkungen der Terroranschläge des 11. September 2001.
Die Terroranschläge des 11. September 2001 in New York City und Washington DC in den USA zerstörten zwei 110-stöckige Bürotürme und ein drittes, 47-stöckiges Bürogebäude am World Trade Center (WTC) in New York sowie Teile des Pentagons in Washington DC. Alle WTC-Gebäude im Plaza-Bereich (Bild 1, blau gekennzeichnet) wurden an diesem Tag ebenfalls zerstört.
Die Türme hatten im Wesentlichen keine Mauerwerk-Komponenten. Allerdings blieben viele der umliegenden Gebäude, die von den Einstürzen betroffen waren, infolge des Mauerwerks in der Konstruktion teilweise erhalten. Die Mauerwerksverkleidung des Pentagons in Washington war vor den Angriffen des 11. September teilweise verstärkt worden und wurde danach wieder aufgebaut.
In den vergangenen zehn Jahren wurde in New York daran gearbeitet, den Bereich des World Trade Centers wieder aufzubauen. Der vorliegende Beitrag zeigt den derzeitigen Stand der Entwicklungen und bestätigt die Widerstandsfähigkeit von Mauerwerk bei dieser großen Katastrophe. Einige der Fotos aus dem Jahr 2013 wurden aufgrund der entstandenen Bauten aus einem anderen Blickwinkel aufgenommen als die Fotos von 2001.

x
Jäger, WolframZum Eurocode 6 - Fragen und AntwortenMauerwerk1/201452-54Leserforum

Kurzfassung

Unter dieser Rubrik werden Fragen beantwortet, die bei der Einarbeitung in den EC 6 entstehen. Die Wiedergabe erfolgt in jedem Falle anonymisiert. Sofern es um Verständnisfragen und Hintergrundinformationen geht, werden sie von den Beiratsmitgliedern beantwortet. Handelt es sich um Auslegungsfragen, wird der zuständige NABau-Ausschuss NA 005-06-01 AA “Mauerwerksbau“ (Sp CEN/TC 125, CEN/TC 250/SC 6) mit einbezogen.
Mit dem Leserforum zum EC 6 soll der Praxis die Einarbeitung in das neue Normenpaket mit seinen Nationalen Anhängen erleichtert werden. Auch Sie können als Leser gern von dieser Rubrik Gebrauch machen und Ihre Fragen stellen (mauerwerk@ernst-und-sohn.de).

Questions concerning the introduction of the EC 6.
Under this heading questions are answered, arising from the application of EC 6. The questions are expressing anonymous in all cases. Provided that they concern the understanding and background information the answers will be given by members of the editorial board. If the questions are dealing with the interpretation of clauses of EC 6 the responsible code committee NA 005-06-01 AA “Masonry construction” (Sp CEN/TC 125, CEN/TC 250/SC 6) will be involved.
The practice should get help for the adjustment in the EC 6 and its National Annexes with this new category of contributions. The readers are invited to avail oneself of this chance very active (mauerwerk@ernst-und-sohn.de).
Die nachfolgenden Fragen und Antworten beziehen sich auf den Teil 1-1 [1] sowie Teil 3 [3] von DIN EN 1996 zusammen mit dem zugehörigen Nationalen Anhang [2].

x
Fritz-Höger-Preis 2014 für Backstein-ArchitekturMauerwerk1/201454Wettbewerbe

Kurzfassung

Keine Kurzfassung verfügbar.

x
Firmen und Verbände: Mauerwerk 1/2014Mauerwerk1/201454-56Firmen und Verbände

Kurzfassung

Plusenergiehaussiedlung überzeugt mit energieeffizientem Konzept
Klimaschutzziele bezahlbar halten - Porenbetonindustrie gerüstet

x
Termine: Mauerwerk 1/2014Mauerwerk1/201456Termine

Kurzfassung

Keine Kurzfassung verfügbar.

x
Inhalt: Stahlbau 1/2014Stahlbau1/2014Inhalt

Kurzfassung

Keine Kurzfassung verfügbar.

x
Jahresinhaltsverzeichnis 2013Stahlbau1/20140Jahresinhaltsverzeichnis

Kurzfassung

Keine Kurzfassung verfügbar.

x