abo_giftabo_onlineabo_printabo_studentabo_testangle_leftangle_rightangle_right_filledarrow_big_downarrow_big_down_filledarrow_big_leftarrow_big_left_filledarrow_big_rightarrow_big_right_filledarrow_big_uparrow_big_up_filledarrow_dropdown_downarrow_dropdown_uparrow_small_leftarrow_small_left_filledarrow_small_rightarrow_small_right_filledarrow_stage_leftarrow_stage_left_filledarrow_stage_rightarrow_stage_right_filledcaret_downcaret_upcloseclose_thinclose_thin_filledcontactdownload_thickdownload_thick_filleddownload_thindownload_thin_filledebookeditelement_headlineelement_labelelement_relatedcontentlockmailminuspagepage_filledpagespages_filledphoneplusprintprint_filledquotationmarks_leftquotationmarks_rightsearchsendshareshare_filledshoppingcart_bigshoppingcart_big_filledshoppingcart_headershoppingcart_smallshoppingcart_small_filledsocial_facebooksocial_linkedinsocial_pinterest social_xsocial_xingsocial_youtubesocial_twitteruser_biguser_small

Artikeldatenbank

Filter zurücksetzen
  • Autor(en)

  • Sprache der Veröffentlichung

  • Erschienen

  • Rubrik

Zeitschriften-Selektion

  • Alle auswählenAlle abwählen
Autor(en)TitelZeitschriftAusgabeSeiteRubrik
Bietz, H.; Scholl, W.Zur Überarbeitung der DIN 4109 "Schallschutz im Hochbau" unter besonderer Berücksichtigung des Holz-/ LeichtbausBauphysik6/2006349-355Fachthemen

Kurzfassung

Die Norm DIN 4109 - Schallschutz im Hochbau regelt alle Belange rund um den baulichen Schallschutz. Hierzu gehören sowohl die Festlegung von Anforderungen, als auch die Beschreibung von Verfahren, mit denen ein geforderter Schallschutz vorhergesagt werden kann (sog. Prognoseverfahren). Weiterhin wird beschrieben, wie ein meßtechnischer Schallschutznachweis grundsätzlich durchzuführen ist. Die Prognoseverfahren beinhalten auch einen Bauteilkatalog mit der Beschreibung der bauakustischen Kenngrößen üblicher Bauteile. DIN 4109 wird zur Zeit aus verschiedenen Gründen komplett überarbeitet. Es werden die Hintergründe der Überarbeitung erläutert sowie die Struktur der neuen Norm vorgestellt. Insbesondere wird auf die Erarbeitung eines neuen Bauteilkataloges für den Bereich der im Holzbau bzw. Leichtbau üblichen Bauteile eingegangen, wobei der jetzt erstellte Bauteilkatalog auch anhand von Beispielen vorgestellt wird. Weiterhin wird auf den aktuellen Sachstand der Überarbeitung von DIN 4109 eingegangen.

x
Hansen, E.Zusammengesetzte Biege- und Druckstäbe aus Holz.Bautechnik7/1971243-248

Kurzfassung

Die Berechnung zusammengesetzter Querschnitte aus Holz mit Berücksichtigung der Nachgiebigkeit der Verbindungsmittel nach DIN 1052.

x
Bogensperger, Thomas; Silly, GregorZweiachsige Lastabtragung von BrettsperrholzplattenBautechnik10/2014742-752Aufsätze

Kurzfassung

Bauen mit massiven Brettsperrholzelementen (BSP-Elementen) gewann in den letzten Jahren an Bedeutung. Beginnend mit dem Einfamilienhausbau vor mehr als 15 Jahren wurden und werden mittlerweile immer größere Bauaufgaben angedacht und realisiert. Als Beispiele der aktuell größten Bauwerke in der Holz-Massivbauweise können der Murray Grove Tower und das Bridboard House - 2008 bzw. 2010 in London errichtet - angeführt werden. Die jeweils achtgeschossigen Bauwerke wurden komplett mit dem noch “jungen” Baustoff Brettsperrholz (BSP) realisiert.
Traditionell erfolgt die Berechnung von Deckenelementen aus BSP als einachsig gespannter Plattenstreifen. Damit kann allerdings nur die Haupttragrichtung der orthotrop wirkenden BSP-Platte erfasst werden. Um auch die Nebentragrichtung für die Bemessung zu nutzen, werden im vorliegenden Beitrag sämtliche Steifigkeitskennwerte von BSP-Platten erläutert. Damit können auch Sonderfälle wie Deckenaussparungen oder punktgestützte Platten, welche eine 2D-Plattenberechnung nach der orthotropen, schubnachgiebigen Plattentheorie (REISSNER-MINDLIN) erfordern, untersucht werden.

Two-axial load transfer of Cross-Laminated-Timber plates
In the last years building activity with solid Cross Laminated Timber (CLT) elements gained remarkable relevance. Starting with single family houses over 15 years ago medium and large sized building construction jobs are analysed and solved in the meantime. Two examples for large multi-storey houses with eight floors each, erected completely with CLT, can be cited here: on the one hand the Murray Grove Tower (2008) and on the other hand the Bridboard House (2010) - both realized in London. Structural design of these CLT-plates is performed traditionally as simply supported uniaxial plate. Only the stronger, more important main direction of CLT-plates, which is defined as the orientation of the outer layers, is treated by this assumption. In order to include the minor important orthogonal direction of CLT in a two dimensional plate theory all plate stiffness coefficients of CLT-plates are illustrated and discussed in the present paper. Consequently special cases as large cutouts in CLT-plates and column supported CLT-plates can be treated with the well known REISSNER-MINDLIN plate theory, which includes deformation due to bending and shear.

x
Horn, Rafael; Gantner, Johannes; Groenewolt, Abel; Krieg, Oliver DavidÖkobilanzierung von Lebensende-Optionen - Szenarien im bauphysikalischen Kontext am Beispiel segmentierter HolzschalenkonstruktionenBauphysik5/2018298-306Fachthemen

Kurzfassung

Die Betrachtung temporärer, modularer Bauwerke aus biobasierten Rohstoffen wie Holz stellt bisher für die Ökobilanzierung eine methodische Herausforderung dar. Durch die Integration probabilistischer und dynamischer Elemente konnte eine Methode entwickelt werden, die belastbare Ökobilanzergebnisse unter Berücksichtigung unsicherer Lebensende-Szenarien und verknüpfter Lebenszyklen ermöglicht. Die Methode wurde am Fallbeispiel einer temporären Leichtbauschalenkonstruktion auf Basis eines modularen Holzbausystems angewendet. Zur Analyse der potenziellen Umweltwirkungen wurde hier beispielhaft das Treibhauspotenzial (GWP - Global Warning Potential) im Rahmen einer Monte-Carlo-Analyse unter Berücksichtigung der Unsicherheiten zukünftiger Nutzung untersucht. Dabei ergeben sich klare Vorteile bei einer hohen Anzahl an Umnutzungen gegenüber einer entsprechend hohen Zahl an Neubauten. Darüber hinaus kann gezeigt werden, dass die potenziellen Umweltwirkungen der Konstruktion mit einer Wahrscheinlichkeit von 87 % kleiner als 0,8 kg CO2-Äquivalente je m2 Nettogrundfläche und Jahr liegen.

Life Cycle Assessment and Life Cycle Costing of end-of-life options for cascade use - Scenarios in the building physics context using the example of lightweight timber constructions
The consideration of temporary, modular buildings based on biobased materials such as wood has so far posed a methodological challenge for life cycle assessment. Based on the integration of probabilistic and dynamic elements, a method could be developed that enables reliable life cycle assessment results taking into account uncertain end-of-life scenarios and linked lifecycles. The method was applied to the case study of a temporary lightweight shell construction based on a modular timber construction system. The potential environmental impacts were analyzed using the example of GWP as part of a Monte Carlo analysis taking into account the uncertainties of future use. There are clear advantages with a high number of conversions compared to a correspondingly high number of new buildings. Furthermore, it could be shown that the potential environmental impacts of the construction are less than 0.8 kg CO2-equivalents per m2 net floor area and year with a probability of 87 %.

x