abo_giftabo_onlineabo_printabo_studentabo_testangle_leftangle_rightangle_right_filledarrow_big_downarrow_big_down_filledarrow_big_leftarrow_big_left_filledarrow_big_rightarrow_big_right_filledarrow_big_uparrow_big_up_filledarrow_dropdown_downarrow_dropdown_uparrow_small_leftarrow_small_left_filledarrow_small_rightarrow_small_right_filledarrow_stage_leftarrow_stage_left_filledarrow_stage_rightarrow_stage_right_filledcaret_downcaret_upcloseclose_thinclose_thin_filledcontactdownload_thickdownload_thick_filleddownload_thindownload_thin_filledebookeditelement_headlineelement_labelelement_relatedcontentlockmailminuspagepage_filledpagespages_filledphoneplusprintprint_filledquotationmarks_leftquotationmarks_rightsearchsendshareshare_filledshoppingcart_bigshoppingcart_big_filledshoppingcart_headershoppingcart_smallshoppingcart_small_filledsocial_facebooksocial_linkedinsocial_pinterest social_xsocial_xingsocial_youtubesocial_twitteruser_biguser_small

Artikeldatenbank

Filter zurücksetzen
  • Autor(en)

  • Sprache der Veröffentlichung

  • Erschienen

  • Rubrik

Zeitschriften-Selektion

  • Alle auswählenAlle abwählen
Autor(en)TitelZeitschriftAusgabeSeiteRubrik
Gundelwein, H.; Grosse, M.; Rautenstrauch, K.Ein Beitrag zur Bemessung von Rippenplatten aus MERK-DickholzBautechnik11/2002737-743Fachthemen

Kurzfassung

Dieser Aufsatz befaßt sich mit den bei Verwendung von Rippenplatten aus MERK-Dickholz (sogenanntes Brettsperrholz) auftretenden Fragestellungen hinsichtlich der Spannungs- und Steifigkeitsermittlung. Auf der Grundlage umfangreicher numerischer Simulationsrechnungen an Rippenplatten wird ein empirisches Bemessungsverfahren entwickelt, welches zu einer Vereinfachung der Nachweisführung in der Baupraxis beitragen kann. An einem Beispiel werden die Vorgehensweise erläutert und die Ergebnisse gegenüber gestellt.

x
Maushake, E.Ein bemerkenswertes Kuppeldach im Deutschen Pavillon zu Montreal.Bautechnik12/1967428

Kurzfassung

Bericht über ein Kuppeldach, dessen Tragkonstruktion durch einen kreuzweise verlegten Lattenrost gebildet wird.

x
Aicher, S.; von Roth, W.Ein modifiziertes "gamma"-Verfahren für das mechanische Analogon: dreischichtiger Sandwichverbund - zweiteiliger verschieblicher Verbund.Bautechnik1/198721-29

Kurzfassung

Auf der Grundlage der Analogie des dreischichtigen Sandwichverbundes mit dem zweiteiligen verschieblichen Verbund darf das "gamma"-Verfahren des Ingenieurholzbaues(DIN 1052, Teil 1) zur Bemessung einiger bauaufsichtlich zugelassener Sandwichelemente verwendet werden. In dieser Arbeit wird zunächst die genannte Analogie in allgemeingültiger Form unter Berücksichtigung von Schwergewichtslasten und der Eigendehnungs- bzw. Eigenspannungsproblematik dargestellt. Anschliessend wird ein für beide Verbundbauweisen gültiges modifiziertes "gamma"-Verfahren hergeleitet, welches ohne wesentlichen Mehraufwand eine exakte Bestimmung der Teischnittmomente und Biegespannungen ermöglicht.

x
Gollwitzer, Th.; Gebbeken, N.Ein neues FEM-Stabelement für nachgiebige VerbundquerschnitteBautechnik7/2004549-554Fachthemen

Kurzfassung

Ein neues FEM-Stabelement für einen n-teiligen, nachgiebigen Verbundquerschnitt wird vorgestellt. Mit Hilfe des Prinzips der virtuellen Arbeit wird die Steifigkeitsmatrix des Elements hergeleitet. Sie besteht aus der Summe der Steifigkeitsmatrizen der Einzelstäbe und der Summe der Steifigkeitsmatrizen der Verbundfugen. Anhand einer bekannten analytischen Lösung des -Verfahrens wird die Lösung verifiziert und validiert. Dem Anwender wird eine maximale Elementlänge l empfohlen.

x
Pischl, R.Ein Pionier des Ingenieurholzbaues. Zum 100. Todestag von Karl Culmann.Bautechnik11/1981361-367

Kurzfassung

Zur Erinnerung an den weltbekannten Ingenieur, Forscher und Lehrer, der zum Ausbau der Baustatik entscheidend beigetragen und dabei dem Holzbau den Weg des wisenschaftlich fundierten Konstruierens bereitet hat.

x
Meyer, Nico; Blaß, Hans JoachimEine neue Prüfmethode für Fachwerkknoten aus HolzBautechnik11/2018793-800Aufsätze

Kurzfassung

Das Trag- und Verformungsverhalten von Verbindungen wird i. d. R. mithilfe von Druck- oder Zugversuchen an einzelnen Bauteilen ermittelt. Diese Bauteile können in der späteren Baupraxis u. a. als Druck- und Zugdiagonalen in Fachwerkträgern eingesetzt werden. Allerdings weisen die Fachwerkknoten, in denen die Diagonalen an die Gurte angeschlossen werden, aufgrund der kombinierten Einleitung von Zug- und Druckkräften ein komplexes Tragverhalten auf. Dieses kann durch Versuche an vollständigen Fachwerkträgern verifiziert werden. Der material- und versuchstechnische Aufwand ist hierbei jedoch sehr hoch, zumal pro Versuchsfachwerk i. d. R. lediglich ein bestimmter Fachwerkknoten untersucht werden kann. Alle übrigen Knoten des Fachwerkträgers dienen allein der Erzeugung der Kräfte in dem zu untersuchenden Knoten. Mit der hier vorgestellten Prüfmethode ist es nun möglich, das Trag- und Verformungsverhalten von Fachwerkknoten praxisnah zu ermitteln, ohne einen kompletten Fachwerkträger prüfen zu müssen. Der Material- und Prüfaufwand reduziert sich dadurch signifikant. Damit ergibt sich die Möglichkeit, verschiedene Einflussparameter mit einer genügenden Anzahl von Einzelversuchen zu untersuchen.

A new test method for timber truss nodes
The load-bearing and deformation behaviour of connections is usually determined by means of compression or tensile tests on single structural elements. These components can be used later in structural applications, for example as compression or tension diagonals in timber trusses. However, the nodes, where diagonals are connected with the chords, show complex load-bearing behaviour due to the combined introduction of tensile and compression forces. This can be verified by tests with complete trusses. However, the material and experimental effort is very high, especially for the examination of the load-bearing behaviour of a single node. All other nodes of the test truss only generate the forces in the node to be examined. With the presented test method, it is now possible to determine the load-bearing and deformation behaviour of truss nodes in a practical manner, without testing complete trusses. The material and testing effort is significantly reduced. Consequently, various influencing parameters with sufficient number of individual experiments may be studied.

x
Natterer, JuliusEinfach- und Hightech-Konstruktionen aus Holz - Eine Chance für energie- und nachhaltigkeitsbewusstes BauenBautechnik1/201347-50Kommentar

Kurzfassung

Wird Holz als nachwachsender Werkstoff das Baumaterial des XXI. Jahrhunderts? In der heutigen Zeit, in der ökologische Überlegungen zunehmend an Bedeutung gewinnen, kann der Werkstoff Holz vor allem unter dem Aspekt der CO2-Emissionen und energetischer Gesichtspunkte gewichtige Trümpfe ausspielen. Zum einen benötigt die Verarbeitung im Vergleich zu anderen Baustoffen nur sehr wenig fossile Energie. Darüber hinaus kann das im Holz abgelagerte CO2 nicht nur sinnvoll “entsorgt” sprich verbaut werden, sondern neues CO2 der Atmosphäre durch Wiederaufforstung gebunden werden.

x
Kreuzinger, Heinrich; Sieder, MikeEinfaches Prüfverfahren zur Bewertung der Schubfestigkeit von Kreuzlagenholz/BrettsperrholzBautechnik5/2013314-316Berichte

Kurzfassung

Im Rahmen der Zustimmung im Einzelfall für die Verwendung eines eingeklebten Verbindungsmittels in kreuzweise verklebten Vollholz beim Projekt “Timber Tower” (Windkraftanlage mit Holzturm) wurde von den Autoren eine gutachterliche Stellungnahme zur Tragfähigkeit und zum Ermüdungsverhalten der Verbindung erarbeitet, welche tangierende Fragestellungen beinhaltete, wie zum Beispiel die Festigkeitswerte des Kreuzlagenholzes/Brettsperrholzes bei Beanspruchung als Schubfeld.

Basic test method for valuation of shear strength of cross laminated timber
In the context of the approval in individual cases for application of glued in fasteners in cross laminated timber at the project “Timber Tower” (wind power station with timber tower) the authors have prepared an expertise for the load-bearing capacity and the fatigue behavior of the connection. Thereby some additional questions arose, for example the strength value of the cross laminated timber in case of stress as a shear field.

x
Bonfig, Peter; Dehlinger, Christian; Cremers, JanEinfamilienhaus? Du darfst! - Die Typologie des kompakten Hofhauses ermöglicht private Wohnformen auf eigenem Grund bei hoher urbaner DichteBautechnik1/202335-44Berichte

Kurzfassung

Das sog. kompakte Hofhaus wurde als neuartiger Hofhaustyp an der Hochschule für Technik Stuttgart (HFT) entwickelt und untersucht. Zu Quartieren addiert stellt er den Bewohnern bei geringem Landverbrauch urbane Lebensräume zur Verfügung und kann hohe Dichte, Diversität von Nutzung sowie ein hohes Maß an Privatheit und Wohnqualität in Innen- wie Außenräumen miteinander vereinen - in Neubau- wie in Bestandsituationen. Definitionsgemäß wird dies dadurch erreicht, dass nicht einsehbare Höfe/Außenräume als ausschließlich private Nutzflächen in die Gebäudestruktur integriert werden (anstelle von exponierten Abstandsflächen mit geringerem Nutzwert außerhalb des Gebäudes) und über diese Bereiche auch die Belichtung und die Belüftung erfolgen können. Innen- und Außenräume können so zu einem geschützten und eng miteinander verzahnten Lebensraum verschmelzen. Die bisherigen Ergebnisse der seit 2017 laufenden DFG-geförderten interdisziplinären Forschungsarbeit weisen mit einer umfangreichen Typologie, allgemeingültigen Lösungsstrategien und vielen Einzeluntersuchungen nach, dass dieser Ansatz bereits auf ungewöhnlich kleinen Parzellen (ca. 60-200 m2) unterschiedlicher Proportion mit bis zu fünfgeschossigen Gebäuden für eine oder mehrere Parteien funktioniert. Einige der aus verschiedenen Grundtypen hervorgehenden Varianten eignen sich als Einfamilienhäuser auf eigenem Grund und können so diese von der Mehrheit angestrebte Wohnform in einem nachhaltigen urbanen Umfeld hoher Dichte und Heterogenität ermöglichen.

Single-family house? You may!
The typology of the compact courtyard house enables private forms of living on one's own land with a high urban density. The so-called compact courtyard house was developed and examined as a new type of courtyard house at the Stuttgart University of Applied Sciences (HFT Stuttgart). Added to neighbourhoods, it provides residents with urban living spaces reducing land consumption and can combine high density, diversity of use and a high degree of privacy and residential quality in both indoor and outdoor spaces - in both new and existing situations. By definition, this is achieved by integrating courtyards/outdoor spaces into the building structure as exclusively private usable areas that can not be looked into (instead of exposed distance areas with lower usable value outside the building) and by providing lighting and ventilation via these areas. Indoor and outdoor spaces can thus merge into a protected and closely interlinked living space. The results to date of the interdisciplinary DFG-funded research work, which has been ongoing since 2017, demonstrate with an extensive typology, generally valid solution strategies and many individual investigations that this approach already works on unusually small plots (approx. 60-200 m2) of varying proportions with up to five-storey buildings for one or more parties. Some of the variants that emerge from different basic types are suitable as single-family houses on their own land and can thus enable this form of housing sought by the majority in a sustainable urban environment of high density and heterogeneity.

x
Klippel, Michael; Frangi, AndreaEinfluss des Klebstoffes auf das Brandverhalten von BrettschichtholzBauphysik4/2012142-152Fachthemen

Kurzfassung

Die Verwendung von Klebstoffen für die Herstellung von Holzprodukten ist im konstruktiven Holzbau unerlässlich. Die Tragsicherheit von verklebten tragenden Holzbauteilen wie Brettschichtholz wird durch das Verhalten der eingesetzten Klebstoffe maßgeblich beeinflusst. Klebstoffe müssen eine zuverlässige Festigkeit und Dauerhaftigkeit aufweisen, so dass sie unter der vorgesehenen Nutzung ihre Funktionsfähigkeit vollständig behalten. Diese Leistungsanforderung muss auch im Brandfall sichergestellt sein. Zur Untersuchung des Einflusses des Klebstoffes auf das Tragverhalten von Brettschichtholz im Brandfall wurden umfangreiche Untersuchungen durchgeführt. Der vorliegende Artikel fasst die wesentlichen Resultate und Erkenntnisse dieser Untersuchungen zusammen. Die Untersuchungen zeigten den Einfluss des Klebstoffes auf das Tragverhalten bei Brettschichtholz im Brandfall. Bei der flächigen Verklebung (zwischen den Brettlamellen) zeigte sich anhand numerischer Untersuchungen, dass ein Versagen in der Klebstofffuge auch mit Klebstoffen mit geringer thermischer Stabilität kaum maßgebend wird. Die Brandversuche an keilgezinkten Brettschichtholzlamellen zeigten, dass der Feuerwiderstand von der Versagensart dominiert wird. Unter Berücksichtigung der beobachteten Bruchbilder ließen sich keine signifikanten Unterschiede zwischen den geprüften Klebstoffen feststellen.

Influence of the adhesive on the fire behaviour of glued laminated timber.
Adhesives are commonly used to produce engineered wood products such as glued laminated timber beams. The load-bearing capacity of these structural timber elements is strongly influenced by the adhesive used. As a consequence, adhesives have to meet requirements regarding strength and durability to ensure the functionality of structural timber elements during the whole lifetime. Also during fire, the performance requirements have to be fulfilled for a certain time period. To investigate the influence of the adhesive on the load-carrying capacity of glued laminated timber in fire, comprehensive analysis has been performed. This article summarises the most important results and findings. Based on the numerical analysis performed to investigate the influence of adhesive in the bondline between two lamellas, it can be concluded that also if the adhesive strength in the bondline is strongly influenced by the temperature, in most common design applications failure will occur because the bending resistance of the beam is exceeded. Failure in the bondline is hardly to be expected. The fire tests on finger-jointed timber boards showed that the fire resistance is dominated by the type of failure. Taking into account the different failure modes, no significant difference was observed between the adhesives studied.

x
Duy, W.Einfluss des Wölbwiderstands auf die Kippsicherheit von gabelgelagerten Holzbalken.Bautechnik2/198851-57

Kurzfassung

Kippuntersuchungen von gabelgelagerten Holzträgern mit h/b > 10 sind unnötig, wenn der Druckgurt von Rechteckquerschnitten im Abstand von a=15 x b bzw. von Sandwichquerschnitten, z.B. von Fachwerkträgern, im Abstand von a=11 x b seitlich unverschieblich gehalten ist. Diese Forderungen stehen im Widerspruch zu bisherigen Festlegungen, wo infolge der verschiedener Annahmen (keine Wölbsteifigkeit, Biegedruckspannungen begrenzt) sich andere Festlegungen zu den erforderlichen Abständen der Kipphalterungen ableiten lassen. Unter Berücksichtigung der Wölbsteifigkeit ergibt sich jedoch wieder eine gute Übereinstimmung.

x
Joscak, Matus; Sonderegger, Walter; Niemz, Peter; Schnider, Thomas; Oppikofer, Reinhard; Lammar, LauraEinfluss von Hohlräumen auf die Wärmeleitfähigkeit von ausgewählten Holzwerkstoffen für den BaueinsatzBauphysik1/201232-37Fachthemen

Kurzfassung

An ausgewählten Holzwerkstoffen (Buchenfurnier, MDF- und Spanplatten) wurde der Einfluss des Einbringens von Hohlräumen auf die Wärmeleitfähigkeit untersucht. Für die Versuche wurden die Platten in mehreren Lagen geschichtet (Lagendicke je nach Material 2,7 bis 5 mm) und die Aufbauten variiert, wobei Platten mit und ohne Hohlräume verwendet wurden. Um den Einfluss der Wärmestrahlung in den Hohlräumen zu untersuchen, wurden zusätzlich Aluminiumfolien (geringer Emissionsgrad) eingelegt. Es konnte festgestellt werden, dass durch das Einbringen von Hohlräumen (Volumenanteil ca. 46 %) eine Reduzierung der Wärmeleitfähigkeit um bis zu 51 % erreicht wird. Ein zusätzliches Einlegen von Aluminiumfolie quer zur Wärmestromrichtung reduziert die Wärmeleitfähigkeitswerte nochmals wesentlich (bis zu 64 %) aufgrund der stark reduzierten Wärmestrahlung in den Hohlräumen. Dies ist besonders ausgeprägt bei den Aufbauten mit größeren Hohlraumdicken. Um das Potential des Anbringens von Hohlräumen im Holzbauwesen zu nutzen, wurde ein Vorschlag für ein neues Produkt auf Holzbasis präsentiert.

Influence of the air cavities on thermal conductivity of selected wood based materials and their application for building industry.
On selected wood-based materials (beech veneer, MDF and particle board), the influence of inserting air cavities on the thermal conductivity was investigated. For the tests, the particular boards (board thickness: 2.7 to 5 mm according to the material) were layered in multiple layers by varying the assemblies and using boards with and without cavities. Additionally, aluminium foils (low emissivity) were inserted to investigate the influence of heat radiation in the cavities. It can be stated that inserting air cavities (approximately 46 % of core material) results in a reduction of thermal conductivity up to 51 %. An additional insertion of aluminium foils perpendicular to the direction of heat flow reduces the thermal conductivity once more significantly (up to 64 %) due to a strong reduced heat radiation within the cavities. This is particularly pronounced in the constructions with larger air cavity thicknesses. Additionally, a proposal of a new product based on wood has been presented to develop the potential of inserting cavities for timber construction.

x
Schmidt, J.; Lämmel, R.; Reuter, C.; Kaliske, M.Einfluß des Kriechens und des Betonschwindens auf das Tragverhalten von Holz/Beton-Verbundbalken - ein erweiterter Bemessungsvorschlag und dessen AnwendungsgrenzenBautechnik7/2005407-415Fachthemen

Kurzfassung

In diesem Beitrag werden die Auswirkungen des Kriechens und des Betonschwindens auf das Tragverhalten der Verbundkonstruktion untersucht. Dabei wird die zeitliche Veränderung der Werkstoffeigenschaften in einem FE-Modell erfaßt. Insbesondere die Berücksichtigung des Verhaltens von jungem Beton führt zu signifikanten Veränderungen des Tragverhaltens im Vergleich zu Verbundkonstruktionen mit vereinfacht konstant angenommenen elastischen Betoneigenschaften. Außerdem wird der Einfluß der Dauer und des Entlastungsprozesses einer temporären Montageunterstützung untersucht, um praxisrelevante Handlungsempfehlungen zu gewinnen. Der um die Verminderung des Tragvermögens infolge Betonschwindens erweiterte Bemessungsvorschlag erlaubt hingegen eine wirtschaftliche Bemessung und gewährleistet ein ausreichendes Sicherheitsniveau zum Versagenszustand.

x
Prietz, F.Einsturz der Dachkonstruktion eines Einkaufsmarktes bei BerlinBautechnik4/2010228-233Berichte

Kurzfassung

Keine Kurzfassung verfügbar.

x
Ringhofer, Andreas; Brandner, Reinhard; Schickhofer, GerhardEntwicklung einer optimierten Schraubengeometrie für hochbeanspruchte Stahl-Holz-VerbindungenBautechnik1/201431-37Aufsätze

Kurzfassung

Der Beitrag behandelt die Optimierung der Geometrie von vorwiegend axial beanspruchten selbstbohrenden Holzschrauben für den Einsatz in einer Stahl-Holz-Laschenverbindung unter Zug parallel zur Faser. Mit Fokus auf den Stahlbruch werden der Kopf und Ansatzbereich des Gewindes adaptiert und die Veränderungen im Last-Verformungsverhalten anhand von Prototypen versuchstechnisch an bauteilgroßen Laschenstößen und mittels einer numerischen Modellierung verifiziert. Es zeigen sich eine gegenüber herkömmlichen Schraubentypen um 2 bis 8 % gesteigerte Tragfähigkeit, eine Verlagerung des Versagens der Schraube von der Stahlblech-Unterkante tiefer in das Holz sowie die Ausbildung eines Fließgelenks am Beginn der geschaffenen Freistrecke. Letzteres lässt einerseits eine homogenere Lastverteilung zwischen den Schrauben infolge eines erheblich gesteigerten Duktilitätspotenzials und andererseits eine Verbesserung des Tragverhaltens solcher Anschlüsse bei Langzeit- und Zugschwellbelastungen erwarten. Zudem wird ein Vorschlag für den Nettoquerschnittsnachweis für zugbeanspruchte Laschenstöße mit selbstbohrenden Holzschrauben unterbreitet.

Development of an optimized screw geometry for high-stressed steel-to-timber joints
This paper deals with the geometrical optimization of mainly axially loaded self-tapping screws applied in steel-to-timber joints under tension parallel to grain. Focusing on steel failure, the head geometry and the zone before the thread were adapted. Consequently, differences to standard products were verified by laboratory tests on full-scale steel-to-timber joints and also by numerical modeling. A 2 to 8 % increase of load bearing resistance, a displacement of the location of screw failure deeper into the timber member as well as the development of a plastic hinge close to the head are the essential results of this study. Especially the yield deformation leads to a more homogenous load sharing between a group of screws, caused by an increased potential of ductility, and to an enhanced bearing behavior under long term as well as pulsating tensile loadings. In addition to that a proposal for the verification of the net cross-section of tensile joints with self-tapping screws is given.

x
Rautenstrauch, Karl; Kästner, Martin; Jahreis, Markus; Hädicke, WolframEntwicklung eines Hochleistungsverbundträgersystems für den IngenieurholzbauBautechnik1/201318-25Aufsätze

Kurzfassung

Anspruchsvolle, weitgespannte Ingenieurholzkonstruktionen werden seit über 100 Jahren überwiegend unter Verwendung von Brettschichtholz realisiert. Durch Weiterentwicklung dieses homogenisierten Holzwerkstoffproduktes zu einem hybriden Hochleistungsbauteil können dem natürlichen Roh- bzw. Baustoff Holz weitere Anwendungsfelder erschlossen werden. Hierzu zählen insbesondere Leichtbaustrukturen mit gesteigerten Anforderungen hinsichtlich aufnehmbarer Lasten, größerer Spannweiten und/oder reduzierter Bauhöhe im Hoch-, Industrie- und Straßenbrückenbau. Wesentliche Optimierungen der Biegetragfähigkeit und der Biegesteifigkeit können durch Verstärkung der Trägerrandbereiche mittels Hochleistungswerkstoffen erreicht werden. Im vorliegenden Beitrag werden innovative Konstruktionsansätze zur Herstellung hocheffizienter Hybridbauteile unter Verwendung von Holz als Hauptbaustoff, polymergebundenen mineralischen Deckschichten zur Druckzonenverstärkung sowie kohlefaser- resp. glasfaser- oder stahlverstärkten Furnierschichtholzlamellen zur Zugzonenverstärkung vorgestellt. Zusätzliche Verstärkungselemente steigern die Schubtragfähigkeit oder verbessern die Aufnahme der Querpressungen an den Auflagern.

Development of a high-performance hybrid beam system for timber engineering
For over 100 years demanding long-span constructions in timber engineering are mainly built using glulam. The further development of this homogenized engineered wood product into a hybrid high-performance component creates new fields of application for wood as a natural raw and building material. This particularly includes lightweight constructions with increased demands in terms of load-bearing capacity, longer spans and/or reduced height for building, industrial and bridge construction. Significant improvements of the flexural strength and stiffness can be achieved by reinforcements of the beam's edge zones using high-performance materials. This article presents innovative construction approaches for the production of a highly efficient hybrid system made of wood as main material. The compression zone is reinforced by a layer of polymer concrete. The tension zone is strengthened either with CFRP-, GFRP- or steel-reinforced lamellas made of laminated veneer lumber (LVL). Additional reinforcing elements increase the shear resistance or improve the transverse load-carrying capacity of the bearings.

x
Schulze, H.Entwicklungen im mitteleuropäischen Holzhausbau in der ersten Hälfte des 20. JahrhundertsBautechnik8/1998576-582Fachthemen

Kurzfassung

In der ersten Hälfte des 20. Jahrhunderts entwickelte sich neben vielen anderen Bauweisen der Holzhausbau vom traditionellen Blockhaus- und Fachwerkbau zu den vielfältigen Sparbauweisen des Holztafel- und Gerippebaus, aus denen viele der heutigen Fertighauskonstruktionen hervorgegangen sind. Ökonomische und politische Zwänge führten zwischen 1935 und 1950 zu einer überproportionalen Entwicklung und Perfektionierung des Barackenbaus, die trotz aller Mängel viele Ansätze für ein sparsames Bauen und eine rationelle (Vor)fertigung bieten.

x
Moser, K.Entwicklungstendenzen im modernen Holzbau.Bautechnik4/1992209-214Berichte

Kurzfassung

Keine Kurzfassung verfügbar.

x
Eisele, M.; Dietrich, W.Entwurf von Fussgängerbrücken aus Rundholz für die Bundesgartenschau Kassel 1981.Bautechnik8/1982274-276

Kurzfassung

Eignung und Ausführungsdetails für Rundhölzer im Ingenieurbau.

x
Blass, H. J.Erdbebenaussteifung von mehrgeschossigen Holzskelettbauten.Bautechnik5/1990171-175

Kurzfassung

Das postelastische Tragwerksverhalten von Aussteifungswänden aus Furnierschichtholz und Holzschrauben wurde mit einer nicht-linearen dynamischen Analyse abgeschätzt. Tastversuche mit biegesteifen Verbindungen aus Furnierschichtholz mit nicht vorgebohrten Holzschrauben zeigten das gleiche hysteretische Verhalten wie entsprechende Verbindungen aus Brettschichtholz mit Stabdübeln. Die erstmals ausgeführte Konstruktion der Wandscheiben wurde insbesondere im Hinblick auf eine hohe Energiedissipation geplant. Die Ergebnisse zeigen, daß Erdbebenaussteifungen in Holzbauweise möglich sind, die konsequent plastische Verformungsmöglichkeiten bereitstellen und damit der Forderung nach ausreichender Zähigkeit von Bauwerken in Erdbebengebieten gerecht werden.

x
Kneidl, R.; Seiler, C.Erfahrungen bei der Anwendung der neuen DIN 1052 mit Vergleichen zur VorgängernormBautechnik10/2009603-613Fachthemen

Kurzfassung

Mit Einführung der neuen DIN 1052 kommen nun auch im Holzbau das semiprobabilistische Sicherheitskonzept sowie neue Bemessungsregeln und zum Teil erheblich abgeminderte Festigkeitswerte im Vergleich zur alten Norm zur Anwendung. Um die Auswirkungen der niedrigeren Querdruckfestigkeiten aufzuzeigen, werden Vergleichsrechnungen am Beispiel einer eingespannten Stütze und eines Einfeldträgers durchgeführt und einige kritische Anmerkungen zu den in vielen Fällen erforderlichen Verstärkungsmaßnahmen gemacht. Bei Holzbalkendecken wird dargestellt, dass die neu aufgenommenen Empfehlungen zum Schwingungsnachweis die erforderliche Konstruktionshöhe bestimmen und damit Holzbalkendecken für größere Spannweiten unwirtschaftlich werden. Insgesamt zeigt sich bei Anwendung der neuen DIN 1052, dass der Planungsaufwand gegenüber der alten Norm erheblich anwächst.

Experience in application of the new German code DIN 1052 in comparison with the previous standard.
With the new German code DIN 1052 the semi-probabilistic safety concept has been introduced for timber constructions as well as new design procedures and to some extent considerably reduced strength properties in comparison to the previous standard. For illustration of the impact of the low lateral pressure strength comparative calculations are performed using a clamped column and a simply supported beam and some critical comments are given for strengthening measurements required in many cases. For timber beam ceilings it is shown that the new recommendations for vibration control govern the required construction height und make such constructions inefficient for longer span lengths. In general, the complexity applying the new DIN 1052 is considerably higher than designing on the basis of the previous standard.

x
Szalai, J.Ermittlung der während der Herstellung auftretenden Eigenspannungen und Verformungen bei gekrümmten Brettschichtträgern.Bautechnik2/198337-41, 87-90

Kurzfassung

Es wird über die Herstellung von gekrümmten Brettschichtträgern und über die dadurch bedingten Eigenspannungen berichtet. Es wird ein einfaches Näherungsverfahren zur Bestimmung der Eigenspannungen vorgeschlagen und mit einem Beispiel erläutert.

x
Möller, G.Ermittlung von Stabilisierungslasten im HolzbauBautechnik6/2004480-487Fachthemen

Kurzfassung

Die Ermittlung von Stabilisierungslasten für Aussteifungsverbände erfolgt üblicherweise nach einem vereinfachten Verfahren der Holzbaunorm. Im vorliegenden Aufsatz werden zwei Verfahren für eine genaue Ermittlung der Stabilisierungskräfte vorgestellt. Das eine Verfahren beruht auf der Energiemethode und ist gültig für gabelgelagerte Einfeldträger mit kontinuierlicher seitlicher Stützung. Für Einfeldträger mit Belastung durch konstante Normalkräfte oder Biegemomente können hieraus Gleichungen für die Ermittlung der Seitenlast ermittelt werden. Eine weitere Nachweismöglichkeit ist die Ermittlung der Seitenlasten nach der Biegetorsionstheorie II. Ordnung für den räumlich belasteten und punktuell seitlich gestützten Stab für beliebige Lagerung und Belastung unter Verwendung des Übertragungsverfahrens. Die Ergebnisse beider Verfahren werden anhand von Beispielen verglichen.

x
Erster innerstädtischer Siebengeschosser in HolzbauweiseBautechnik8/2008511Bautechnik aktuell

Kurzfassung

Keine Kurzfassung verfügbar.

x
Gariglio, Federico; Schnider, Thomas; Niemz, Peter; Ghazi Wakili, Karim; Brombacher, VolkerExperimentelle und numerische Untersuchung des hygrothermischen Verhaltens von Flachdachelementen mit HohlkastensystemBauphysik1/201517-30Fachthemen

Kurzfassung

Nichtbelüftete Flachdachkonstruktionen in Holzbauweise erfordern aufgrund ihrer Kompaktheit tiefere Kenntnisse hinsichtlich deren bauphysikalischer Vorgänge im Dach. Dabei weist vor allem die Dachschalung aus Holz unterhalb der dampfdiffusionsdichten Schicht ein feuchtetechnisch erhöhtes Gefahrenpotential auf. Untersuchungen haben gezeigt, dass eine Überschreitung von 20 % Holzfeuchte über eine längere Zeitdauer erhebliche Folgen wie Befall durch Schimmelpilze oder holzzerstörende Pilze bedeuten kann. Auch die Verklebung kann bei so hohen Holzfeuchten deutlich beeinträchtigt werden. Aus diesem Grund wurde im Rahmen eines Forschungsprojektes beim Neubau eines Zweifamilienhauses Messtechnik im Hohlkastensystem installiert und die Konstruktion über mehrere Jahre überwacht. In die Dachkonstruktion wurden vergleichend Mineralwolle- und eine Holzfaserdämmung eingebaut. Zur Beurteilung des Feuchtegehaltes der Dachschalung wurde dabei auf zwei experimentelle und ein numerisches Verfahren zurückgegriffen.
Das erste experimentelle Verfahren basiert auf der Berechnung der Holzfeuchte aus den gemessenen relativen Luftfeuchten im Dach. Hierfür wurde speziell die Sorptionsisotherme der verwendeten Dreischichtplatten ermittelt. Parallel dazu wurde die Holzfeuchte mittels Widerstandsmessung in den Bereichen mit Holzfaser- bzw. Mineralwolledämmung bestimmt. Zum Vergleich dieser experimentellen Verfahren wurde numerisch eine instationäre hygrothermische Bauteilberechnung mittels WUFI® simuliert.
Alle drei Verfahren ergeben plausible Ergebnisse. Aufgrund der maximalen Abweichungen von 2 % untereinander kann davon ausgegangen werden, dass sich der Verlauf der Ausgleichsfeuchte der Dreischichtplatte in einem Bereich zwischen ca. 11 bis 19 % Holzfeuchte bewegt. Somit liegt sie unter der kritischen Grenze von 20 % und stellt theoretisch keine feuchtetechnische Gefahr dar. Nichtdestotrotz muss aber die Feuchtebeständigkeit der Verklebung dabei unbedingt ebenfalls beachtet werden.

Experimental and numerical investigation on the hygrothermal behaviour of flat roof elements made in hollow boxed construction.
Due to their compactness non-ventilated flat roof constructions in wood require deeper knowledge about the construction-physical processes. The wooden roof sheathing below the vapour diffusion tight layer, in particular, runs an increased risk of hygric properties. Studies have shown that an excess of 20 % moisture content during a longer period of time implicates significant consequences, such as moulds, etc. The bonding can be significantly affected at such high moisture contents. For this reason, as part of a research project a measurement technology was installed during the new construction of a two family house and monitored over several years.
For comparative analysis areas with mineral fibrous and soft fibrous insulating material were established. Two experimental and one numerical methods were applied in order to assess the moisture content of the installed three-layer panel.
The first experimental method is based on the calculation of the moisture content from the measured relative humidity in the roof. For this, the sorption isotherm of three-layer panel used was determined. At the same time, the moisture content was recorded by resistance measurement in the areas with the mineral fibrous and soft fibrous insulating material. A transient hygrothermal calculation using the simulation program WUFI® was carried out for comparison of these experimental methods.
All three methods produce plausible results. Because of the maximum deviation of 2 % of one from another it can be assumed that the fluctuating behaviour of the equilibrium moisture content of the three-layer panel most likely moves in a range between about 11 to 19 % moisture. Thus it is situated below the critical limit of 20 % and does in theory not constitute a risk of hygric properties. Nevertheless the range of 20 % is quite high, for which reason the moisture resistance of the bond thereby should be noted.

x