abo_giftabo_onlineabo_printabo_studentabo_testangle_leftangle_rightangle_right_filledarrow_big_downarrow_big_down_filledarrow_big_leftarrow_big_left_filledarrow_big_rightarrow_big_right_filledarrow_big_uparrow_big_up_filledarrow_dropdown_downarrow_dropdown_uparrow_small_leftarrow_small_left_filledarrow_small_rightarrow_small_right_filledarrow_stage_leftarrow_stage_left_filledarrow_stage_rightarrow_stage_right_filledcaret_downcaret_upcloseclose_thinclose_thin_filledcontactdownload_thickdownload_thick_filleddownload_thindownload_thin_filledebookeditelement_headlineelement_labelelement_relatedcontentlockmailminuspagepage_filledpagespages_filledphoneplusprintprint_filledquotationmarks_leftquotationmarks_rightsearchsendshareshare_filledshoppingcart_bigshoppingcart_big_filledshoppingcart_headershoppingcart_smallshoppingcart_small_filledsocial_facebooksocial_linkedinsocial_pinterestsocial_twittersocial_xingsocial_youtubeuser_biguser_small

Artikeldatenbank

Filter zurücksetzen
  • Autor(en)

  • Sprache der Veröffentlichung

  • Erschienen

  • Rubrik

Zeitschriften-Selektion

  • Alle auswählenAlle abwählen
Autor(en)TitelZeitschriftAusgabeSeiteRubrik
Update on the revision of Eurocode 3 - Evolution by improvement and harmonizationStahlbau2/2021143Empfehlungen der Redaktion

Kurzfassung

Keine Kurzfassung verfügbar.

x
Stahlbau aktuell 2/2021Stahlbau2/2021145-152Stahlbau aktuell

Kurzfassung

Stahlbau Quiz:
Stahlbau Quiz 2020 - Wer weiß es noch?

Aktuelles:
Deutsche Bahn hat DBS 918005 aktualisiert
Ausgepackt! Die Neue Nationalgalerie erstrahlt in altem Glanz

Wettbewerbe:
Oodi Central Library in Helsinki gewinnt Detail Preis 2020
Videos zum Deutschen Ingenieurbaupreis 2020 verfügbar

Tagungen & Veranstaltungen:
International Colloquium on Stability and Ductility of Steel Structures 2022 in Aveiro, Portugal
Structural member stability in the second generation of Eurocode 3
STCO Online-Live-Seminar #2 mit Prof. Knobloch, Prof. Kuhlmann, Prof. Taras

Rezension:
Brücken und Tunnel der Bundesfernstraßen 2020
Seeßelbergs Klassiker “Kranbahnen” in 6. Auflage erschienen

Einen Besuch wert:
Landmarke Lausitzer Seenland

IFBS news:
IFBS-Factsheet zur Kennzeichnung im Metallleichtbau aktualisiert
Neues IFBS-Factsheet zur EU-Bauproduktenverordnung

ÖSTV News:
Neue ÖSTV-Richtline Befestigungstechnik - Dübeltechnik

SZS steel news:
Schweizer steelday+ am 7. Oktober 2021 im Stadion Wankdorf Bern

x
Kongresse - Symposien - Seminare - MessenStahlbau2/2021153Veranstaltungskalender

Kurzfassung

Keine Kurzfassung verfügbar.

x
Ernst & Sohn (Hrsg.)UBB 2/2021 - GesamtausgabeUnternehmerBrief Bauwirtschaft2/20211-32Gesamtausgabe

Kurzfassung

Keine Kurzfassung verfügbar.

x
Titelbild: Bauphysik 1/2021Bauphysik1/2021Titelbild

Kurzfassung

Zum Titelbild:
Das Aktivhotel Inselsberg im Thüringer Wald wurde auf einer Fläche von 1.300 m2 mit Natur-Klimadecken aus Hochleistungs-Lehmmodulen von AgrillaTherm ausgestattet. Zu den Vorzügen des Heizens von der Deckenfläche aus zählen eine höhere Reaktionsschnelligkeit im Vergleich zur Fußbodenheizung, da Möbel oder Bodenbeläge nicht die Effizienz mindern. Auch wird der nahezu hundertprozentige Anteil an Strahlungswärme als sehr angenehm empfunden und Staubverwirbelungen gehören der Vergangenheit an. - Ein Raumklima, das auch Allergiker oder Menschen mit Atemwegserkrankungen frei atmen lässt.
(Foto: Aktivhotel Inselsberg)

x
Inhalt: Bauphysik 1/2021Bauphysik1/2021Inhalt

Kurzfassung

Keine Kurzfassung verfügbar.

x
Bauphysik: Jahresinhaltsverzeichnis des 42. Jahrgangs 2020Bauphysik1/2021Jahresinhaltsverzeichnis

Kurzfassung

Keine Kurzfassung verfügbar.

x
Kain, Günther; Idam, Friedrich; Huber, Alfons; Goldsteiner, MarkusLuftbrunnenanlage des Burgtheaters Wien: Nachhaltige KlimatisierungsstrategienBauphysik1/20211-11Aufsätze

Kurzfassung

Das Ende des 19. Jahrhunderts errichtete Burgtheater in Wien ist eines der bedeutendsten Sprechtheater Europas. Es verfügt über eine aus der Errichtungszeit stammende Luftbrunnenanlage zur Frischluftversorgung und Konditionierung des Zuschauerhauses. Dabei wird Frischluft im nahegelegenen Volksgarten angesaugt und über einen unterirdischen Gang und Bodenauslässe in den Zuschauerraum geführt. Warme, verbrauchte Luft wird über die Decke des Zuschauerhauses und eine drehbare Öffnung auf dem Dach des Theaters abgeführt. Im Rahmen der vorliegenden Untersuchung wurden an maßgeblichen Stellen des Belüftungssystems Sensoren zur Überwachung von Lufttemperatur, Luftgeschwindigkeit und Luftfeuchtigkeit platziert. Schließlich wurden Optimierungspotenziale in der Betriebssteuerung und eine adiabate Luftkühlung durch Wasservernebelung evaluiert. Es konnten dabei erfolgsversprechende Handlungsoptionen zur nachhaltigen Konditionierung des Burgtheaters formuliert werden.

Air well system of the Burgtheater Vienna: sustainable cooling strategies
The Burgtheater Vienna was built at the end of the 19th century and it is one of the most important straight theatres in Europe. It is equipped with an air well system for the fresh air supply and conditioning of the auditorium. The air is drawn in at the Volksgarten nearby and led to the auditorium via an underground tunnel. Warm and used air is dissipated through the ceiling and the roof of the theatre. The original dimensions of the facilities are still apparent.
In the framework of this study, temperature, humidity and air velocity sensors were positioned at significant places along the ventilation system and the data was evaluated over the summer 2019. As a result, optimization potentials regarding operation control and air cooling using water atomization were evaluated. Finally, it was shown that the air well system can be used to sustainably condition the theatre in a time of rising temperatures.

x
Neufassung DIN 4108-4 mit neuen Bemessungsgrundlagen für Kork beim WärmeschutzBauphysik1/202111Technische Regelsetzung

Kurzfassung

Keine Kurzfassung verfügbar.

x
Horst, Patricia; Messari-Becker, LamiaKommunale Sporthallen in Deutschland - Bestandssituation und PerspektivenBauphysik1/202112-17Aufsätze

Kurzfassung

Sportstätten haben sowohl im Hinblick auf ihre soziokulturelle Funktion als auch aus Sicht des gebäudebezogenen Umwelt- und Klimaschutzes eine besondere Bedeutung. Den größten Anteil deutscher Sportstätten bilden Sporthallen, die vorwiegend durch die Kommunen betrieben werden und größtenteils zu Zeiten des Goldenen Plans (1960/70er-Jahre) erbaut wurden. Um die positiven Effekte auf das Sporttreiben und somit auf die Lebensqualität sowie auf das Erreichen der gebäudebezogenen Umwelt- und Klimaschutzziele nutzen zu können, bedarf es einer definierten Quantität und Qualität dieser Anlagen. Inwieweit die Sportstätten - insbesondere kommunale Sporthallen - den quantitativen und qualitativen Bedarf decken können und welche Perspektiven für den Sporthallenbestand aus Sicht der Nachhaltigkeit resultieren, wird im folgenden Aufsatz diskutiert.

Municipal sports halls in Germany - Current situation and perspectives
Sports facilities have a special socio-cultural significance as well as an important role with regard to environmental and climate protection in the building sector.
The largest share of German sports facilities are sports halls, which are mainly operated by the municipalities and were mostly built during the so-called Golden Plan (1960/70s). In order to take advantage of the positive effects of sports on the quality of life and to activate the CO2 reduction potential of sports facilities, a certain quantity and quality of these buildings is required.
The following article discusses the extent to which sports facilities - especially municipal sports halls - can meet the quantitative and qualitative requirements and which perspectives for existing sports halls result from a sustainability perspective.

x
Neubauer, Reinhard O.Schalldämmung und Schallschutz - Vergleich von bewertetem Bau-Schalldämm-Maß R'w und bewerteter Standard-Schallpegeldifferenz DnT, wBauphysik1/202118-26Aufsätze

Kurzfassung

In DIN 4109 wird die Schalldämmung, ausgedrückt mit der kennzeichnenden Größe R'w, zur Beschreibung des Schallschutzes verwendet. Schalldämmung und Schallschutz beschreiben jedoch unterschiedliche Sachverhalte. Die Schalldämmung kennzeichnet eine Qualität eines Trennbauteils als “Widerstand” mit der kennzeichnenden Größe “Schalldämm-Maß, R” und der Schallschutz beschreibt eine Qualität des Schutzes zwischen zwei Räumen vor Schallübertragungen und wird mit der kennzeichnenden Größe “Schallpegeldifferenz, D” ausgedrückt. Durch Vergleich beider Kenngrößen wird klar, dass ein Unterschied bestehen muss, der sich nicht nur algebraisch in den Gleichungen darstellen lässt. Werden gleiche Räume objektiv und subjektiv untersucht, zeigen sich Unterschiede sowohl in der Einzahlangabe als auch in der Wahrnehmung. Insbesondere im Hörvergleich hat sich gezeigt, dass das bewertete Schalldämm-Maß (R'w) uneinheitlich in subjektiver Hinsicht bewertet wird, wohingegen die bewertete Standard-Schallpegeldifferenz (DnT, w) eine deutliche “Korrelation” zeigt.

Sound insulation and soundproofing. Comparison of weighted normalized apparent sound reduction index R'w and weighted standardized level difference DnT, w
In the German standard DIN 4109, sound insulation, expressed by the characteristic quantity “R'w”, is used to indicate soundproofing. However, sound insulation and soundproofing describe different facts. Sound insulation indicates a quality of a separating element as “resistance” with the characteristic quantity “sound reduction index, R” and soundproofing describes a quality of protection between two rooms against sound transmissions and is expressed by the characteristic quantity “level difference, D”. By comparing the two measures, it becomes clear that there must be a “difference” that can be represented not only algebraically in the equations. If the same rooms are examined objectively and subjectively, differences can be seen in both the number indication and the perception. In particular, it has been shown that the the rated normalized apparent sound reduction index (R'w) is assessed inconsistently in subjective terms, whereas the rated standardized level difference (DnT, w) shows a strong “correlation”.

x
Hoffmann, Sabine; Kheybari, Abolfazl GanjiUntersuchungen zum sommerlichen Wärmeschutz - Teil 1: Vergleich der Nachweisverfahren unter Berücksichtigung zukünftiger KlimadatenBauphysik1/202127-35Aufsätze

Kurzfassung

In einer dreiteiligen Artikelreihe wird der Nachweis des sommerlichen Wärmeschutzes mit verschiedenen Methoden und unterschiedlichen Randbedingungen untersucht. Während Teil 1 die herkömmlichen Verfahren nach DIN 4108-2 miteinander vergleicht und unter dem Aspekt der sich verändernden Klimabedingungen betrachtet, beschäftigt sich Teil 2 mit mehrdimensionalen Simulationsansätzen für Sonnenschutz. In Teil 3 werden zusätzlich Modellierungsverfahren vorgestellt, die für die korrekte Wiedergabe spezieller Geometrien und hoch reflektierender Materialien bei Verschattungssystemen von Bedeutung sind.
Im vorliegenden Teil 1 der Artikelreihe wird eine Analyse der herkömmlichen Nachweisverfahren, nämlich des Tabellenverfahrens mit Sonneneintragskennwert sowie der dynamischen Gebäudesimulation, durchgeführt. Beide Methoden werden im Hinblick auf die Auswirkungen wichtiger Aspekte und Maßnahmen des sommerlichen Wärmeschutzes (Klimaregion, Orientierung, Fensterflächenanteil, Lüftung, thermische Masse, Sonnenschutz) untersucht und mit einander verglichen. Für die Gebäudesimulation werden neben dem vorgeschriebenen Klimadatensatz (TRY 2010) auch Zukunftsklimadaten verwendet, die den Zeitraum 2021 - 2050 repräsentieren (TRY 2035).

Investigation on thermal protection in summer - part 1: Comparison of the evaluation methods taking into account future climate data
A series of three articles investigates the thermal protection of buildings in summer using different methods and boundary conditions. Part 1 compares the code compliance methods prescribed by DIN 4108-2 and considers future climate data. Part 2 deals with multi-dimensional approaches to model shading systems. Part 3 presents a new approach to model shading systems that consist of non-standard geometries and highly reflective materials.
In part 1 an analysis of the existing code compliance methods is conducted, in particular of the simplified table-based method and the simulation-based approach. Both methods are assessed and compared regarding the impact of important aspects and measures (climate region, orientation, window-to-wall ration, ventilation, thermal mass, shading systems). In the dynamic simulation not only the current weather data (TRY 2010) but also weather data describing the period from 2021 to 2050 (TRY2035) are used.

x
Worch, AnatolInnendämmung und Oberflächentemperaturen an einbindenden InnenwändenBauphysik1/202137-43Aufsätze

Kurzfassung

Innendämmungen werden neben dem bekannten Kondensationspotenzial in der sogenannten Tauebene vor allem mit zusätzlichen Wärmebrücken verbunden. Durch die damit einhergehende Temperaturabsenkung werden in aller Regel zusätzliche Dämmmaßnahmen an den Flanken vorgeschrieben. Ziel der hier vorgestellten Parameterstudie ist es, die Grenzen zu bestimmen, ab denen keine zusätzlichen Dämmmaßnahmen an den Flanken der einbindenden Bauteile notwendig sind. Schwerpunkt liegt hierbei auf dem besonders kritischen Fall, dass die Innendämmung nur an einer Seite des einbindenden Bauteils angebracht ist. Die Oberflächentemperatur an der der Innendämmung abgewandten Seite wird durch eine Flankendämmung nochmals erniedrigt. Gerade dieser Punkt sorgt in der Baupraxis immer wieder für große Unsicherheiten und damit zu einer prinzipiellen Vermeidung von Innendämmungen.
Im Rahmen einer umfangreichen Parameterstudie soll der Mindestwärmedurchlasswiderstand der Außenwand ermittelt werden, ab der keine zusätzlichen flankierenden Maßnahmen mehr notwendig sind. Als eine maßgebliche Grenze kann ein Wärmedurchlasswiderstand der Außenwand größer 0, 8 (m2K)/W ermittelt werden. Oberhalb dieser Grenze sind in aller Regel wohl keine zusätzlichen Dämmmaßnahmen notwendig. Weitere wichtige Zusammenhänge der maßgeblichen Einflussparameter werden diskutiert und vorgestellt.

Internal thermal insulation and surface temperatures on intersecting internal walls
Internal thermal insulations are associated with the condensation risk between the masonry and the insulation material as well as with complicate thermal bridges caused by the fact that the insulation layer will be disturbed in a regularly way. Especially the de-creasing surface temperature may cause mold growing in the near of the thermal bridges. To solve this problem, it is strongly recommended in Germany to add additional insulation materials on the intersecting walls to shift the surface temperature in an uncritical range. The surface temperature on the side facing away from the internal thermal insulation is lowered additionally caused by the additional thermal insulation of the intersecting wall. This is the point that repeatedly causes great uncertainties in building practice and thus leads to a general avoidance of internal thermal insulation systems.
As a main part of an extensive parameter study, the minimum thermal resistance of the external wall should be determined from which no additional measures are necessary. A thermal resistance of the external wall greater than 0.8 (m2K)/W can be calculated as the decisive border line. No additional insulation measures should be necessary above this limit. Further important relationships between the relevant influencing parameters are discussed and presented.

x
Bechtel, Steffen; Scholzen, FrankWärmemarktstudie für das Großherzogtum Luxemburg - Eine Analyse des Wärmemarktes im Kontext nationaler Rahmenbedingungen und energiepolitischer ZielsetzungenBauphysik1/202145-50Aufsätze

Kurzfassung

In 2020 hat Luxemburg seinen Klimaplan für den Zeitraum 2021 bis 2030 beschlossen, welcher ehrgeizige Ziele für den Wärmesektor enthält. Die Datenlage im Wärmesektor, vor allem bei der Schlüsseltechnologie Wärmepumpe, ist jedoch unzureichend, zum Nachteil aller beteiligten Akteure. Die Universität Luxemburg hat deshalb eine Wärmemarktstudie erstellt, die Verkaufszahlen nationaler Hersteller und Händler im Zeitraum von 2014 bis 2018 auswertet und auf diese Weise wesentliche Trends im Hinblick auf die Klimaziele aufzeigt. Die Auswertung zeigt signifikante Unterschiede zur bisherigen Datenlage bei Wärmepumpen, die sich aufgrund der Nichtinanspruchnahme der staatlichen Förderung ergeben. Insgesamt werden deutlich mehr Anlagen installiert als bisher angenommen Der Absatz fossiler Heizkessel ist konstant, wobei eine Verschiebung des Energieträgers von Öl zu Erdgas zu verzeichnen ist. Der allgemeine Trend bewegt sich in Richtung der gesteckten Ziele. Dennoch besteht signifikanter Handlungsbedarf, da zum Erreichen der nationalen Klimaziele u. a. ein jährliches Wachstum des Luxemburger Wärmepumpenmarktes von 16 % bis 2030 angenommen wurde.

Heat Market study for the Grand Duchy of Luxembourg. An analysis of the heat market considering the national framework and energy policies
In 2020, Luxembourg passed its Climate Plan for the period of 2021-2030 which includes ambitious targets for the heat sector. To the disadvantage of all actors in the field, the available data is inadequate. This is especially true for heat pumps that are a key technology for the energy transition. In order to address this issue, the University of Luxembourg created a heat market study that analyzes the sales figures of national manufacturers and retailers for the period of 2014-2018 and shows relevant trends. The evaluation arrives at a significantly different result regarding heat pumps, contrary to existing data. The main reason for that is the non-utilization of state subsidies which leads to considerably more heat pumps installed than actually listed. The sales figures for heating boilers remain largely unchanged, although there is a noticeable shift in the utilized energy source from oil to gas. The overall trend is going towards the targeted direction. Nevertheless, there is a crucial need for action since the accomplishment of the climate objectives is based a.o. on a yearly growth of the Luxemburgish heat pump market by 16 % until 2030.

x
Neu: DEGA-Preis für KommunikationsräumeBauphysik1/202149Aktuell

Kurzfassung

Keine Kurzfassung verfügbar.

x
Hammes, Sascha; Weninger, Johannes; Geisler-Moroder, David; Pfluger, Rainer; Pohl, WilfriedReduzierung des Kunstlichteinsatzes durch Anpassung der Nachlaufzeit an individuelle AnwesenheitsmusterBauphysik1/202150-64Aufsätze

Kurzfassung

Gegenwärtig sind präsenzgesteuerte Beleuchtungssysteme meist an konstante und relativ lange Ausschaltverzögerungen gekoppelt, um die Systemakzeptanz gegenüber fehlerhafter Abwesenheitsdetektion sicherzustellen. Die dabei zur Anwendung kommenden, generalisierten und für alle Arbeitsplätze und Gebäudenutzenden gleichen Abschaltzeiten werden meist bereits vor der Erstinbetriebnahme entschieden. Eine Berücksichtigung von Nutzerindividualitäten, welche durch Tätigkeitsprofil und Unternehmenskultur maßgeblich beeinflusst werden, bleibt dabei außen vor. Dabei nehmen Nutzerindividualitäten eine entscheidende Rolle bei der Umsetzung von Konzepten ein, die die energetische Systemperformanz steigern. Die im Folgenden vorgestellte Studie untersucht daher auf Basis von Belegungsdaten die Auswirkungen des Verhaltens von Gebäudenutzenden auf den Energiebedarf. Die identifizierten Anwesenheitsmuster dienen dazu, die Beleuchtungssteuerung auf individueller Ebene zuzuschneiden. Die Ergebnisse führen auf, dass eine signifikante Reduktion der Ausschaltverzögerung und des damit verbundenen Energiebedarfs ohne negative Auswirkungen auf Systemakzeptanzraten oder Nutzerkomfort möglich ist. Eine hohe räumliche Sensorauflösung erweist sich dabei jedoch als Ausgleich zu potenziell erhöhten Falsch-Aus-Raten als erforderlich. In diesem Zusammenhang wird die Bedeutung der Sensorpositionierung und -anzahl herausgestellt.

Reduction of the use of artificial light by adapting the switch-off times to individual presence patterns
Currently, presence-controlled lighting systems are usually coupled to constant and relatively long switch-off delays to ensure system acceptance against faulty absence detection. The generalized switch-off times that are used for all workplaces and buildings are usually decided before the initial start-up. A consideration of user individualities, which are significantly influenced by the activity profile and corporate culture, is not taken into account. User individualities play a decisive role in the implementation of concepts that increase the energy system performance. The study presented in the following therefore examines the effects of the behaviour of building users on energy requirements on the basis of occupancy data. The identified attendance patterns are used to tailor lighting control on an individual level. The results show that a significant reduction of the switch-off delay and the associated energy demand is possible without negative effects on system acceptance rates or user comfort. A high spatial sensor resolution proves to be necessary to compensate for potentially increased false off rates. In this context, the importance of sensor positioning and number is emphasized.

x
Bauphysik Aktuell 1/2021Bauphysik1/202165-70Bauphysik Aktuell

Kurzfassung

Persönliches:
Bauingenieurin Lamia Messari-Becker in den Club of Rome berufen

Aktuell:
DIBt ist Behörde für Schutz vor Radioaktivität in Bauprodukten
BfS-Broschüre zu Radon-Messungen an Arbeitsplätzen
Neues Merkblatt “Mikrobiologischer Bewuchs auf Fassaden - Algen und Pilze”
BBSR ruft Netzwerk Nachhaltige Unterrichtsgebäude ins Leben
Schullüftung mit “Weltraumtechnik fürs Klassenzimmer”
ift-Richtlinie FE-16/2 Einsatzempfehlungen für Fenster in Schulbauten
Filter-Upgrade zur Minderung des Infektionsrisikos

x
Kongresse - Symposien - Seminare - MessenBauphysik1/202170Veranstaltungen

Kurzfassung

Keine Kurzfassung verfügbar.

x
Titelbild: Bautechnik 1/2021Bautechnik1/2021Titelbild

Kurzfassung

Zum Titelbild:
Das Bild zeigt die “Rock and Roll Hall of Fame” und das dazugehörige Museum in Cleveland, United States.
Foto: Lance Anderson/Unsplash

x
Bautechnik: Jahresinhaltsverzeichnis des 97. Jahrgangs 2020Bautechnik1/2021Jahresinhaltsverzeichnis

Kurzfassung

Keine Kurzfassung verfügbar.

x
Inhalt: Bautechnik 1/2021Bautechnik1/2021Inhalt

Kurzfassung

Keine Kurzfassung verfügbar.

x
Grünthal, Gottfried; Bosse, ChristianUnterschiede, Beziehungen und Gemeinsamkeiten der Erdbebenkarten nach bisherigem und neuem Nationalen Anhang zum Eurocode 8 - Erdbebenzonenkarte nach DIN EN 1998-1/NA:2011-01 und Karte der spektralen Antwortbodenbeschleunigungen nach E DIN EN 1998-1/NA:2018-10Bautechnik1/20211-15Aufsätze

Kurzfassung

Die Karte der spektralen elastischen Antwortbodenbeschleunigungen zum Entwurf des neuen Nationalen Anhangs zum EC 8 (E DIN EN 1998-1/NA:2018-10) hat in Anwenderkreisen einige Diskussionen ausgelöst. Diese bezogen sich insbesondere auf den Vergleich zur Erdbebenzonenkarte des bisherigen Nationalen Anhangs (DIN EN 1998-1/NA:2011-01). Grundsätzlich ist zu betonen, dass ein direkter Zusammenhang zwischen den beiden Karten nicht hergestellt werden kann, da diese auf sehr unterschiedlichen Parametrisierungen basieren. Um für weitere Diskussionen eine sachliche Grundlage zu schaffen, werden in diesem Beitrag die grundlegenden Charakteristika beider Berechnungsmodelle, d. h. zu den Erdbebenkarten des bisherigen und des neuen NA, gegenübergestellt. Des Weiteren werden vier Varianten vorgestellt, wie zumindest auf indirektem Wege die beiden unterschiedlichen Kartentypen in Beziehung gesetzt werden können. Im Ergebnis zeigen die Varianten, dass sie einem gemeinsamen Trend folgen.

Differences, relationships and similarities between the earthquake maps according to the previous and the new National Annex to Eurocode 8 - Earthquake zone map according to DIN EN 1998-1/NA:2011-01 and map of spectral response ground accelerations according to E DIN EN 1998-1/NA:2018-10
The map of the spectral elastic response ground accelerations for the draft of the new National Annex to EC 8 (E DIN EN 1998-1/NA:2018-10) has triggered some discussion. These were related to the comparison with the earthquake zone map of the previous National Annex (DIN EN 1998 1/NA:2011-01). Basically, it has to be emphasized that a direct connection between the two maps cannot be established, since they are based on very different parameterizations. In order to provide a factual basis for further discussions, this article compares the basic characteristics of both calculation models, i.e. the earthquake maps of the previous and the new NA. In addition, four variants are presented to show how the two different map types can be related, at least indirectly. For this purpose, basic limitations associated with such relationships are described. As a result, the variants show that they follow a common trend, apart from a few systematic deviations, both to smaller and to larger values.

x
Grünthal, GottfriedVergleich der neuen Erdbebengefährdungskarten der Schweiz, Deutschlands, Österreichs und Frankreichs für die Nationalen Anhänge zum Eurocode 8Bautechnik1/202117-20Aufsätze

Kurzfassung

Der Vergleich der neuen Erdbebengefährdungskarten für die Schweiz, Deutschland, Österreich und für Frankreich, die für die Nationalen Anhänge zum Eurocode 8 entwickelt wurden, ist Gegenstand dieser Studie. Die vorgestellte gemeinsame Karte überdeckt den südlichen Teil Deutschlands samt angrenzender Gebiete der genannten Nachbarländer. Die Parametrisierung der Karte erfolgt für die Spitzenbodenbeschleunigung, für eine mittlere Wiederholungsperiode von 475 Jahren, für Medianwerte und für einen Untergrund mit einer mittleren Scherwellengeschwindigkeit der obersten 30 m von 800 m/s. Entlang des Grenzverlaufs zwischen Deutschland und den südlichen Nachbarländern zeigen die Konturlinien der unabhängig voneinander berechneten Erdbebengefährdungskarten insgesamt eine erstaunlich gute Übereinstimmung. Das gilt insbesondere für Gebiete relativ erhöhter Erdbebengefährdung. Diese gute bis sehr gute Übereinstimmung kann als Indiz für die Belastbarkeit der Einschätzungen angesehen werden.

Comparison of the new seismic hazard maps of Switzerland, Germany, Austria and France for the National Annexes to Eurocode 8
The comparison of the new seismic hazard maps for Switzerland, Germany, Austria and France, which were developed for the National Annexes to Eurocode 8, is the subject of this study. The presented common map covers the southern part of Germany together with adjacent areas of the mentioned neighbouring countries. The map is parameterised for peak soil acceleration (PGA), for a mean return period of 475 years, for median values and for a subsoil with a mean shear wave velocity of the uppermost 30 m of 800 m/s. Along the boundary between Germany and its southern neighbours, the contour lines of the independently calculated seismic hazard maps show an astonishingly good overall agreement. Slightly more significant deviations are only observed for areas with lower seismic hazard. This good to very good agreement can be seen as an indication of the resilience and thus realistic assessments.

x
Bewerbungsstart für den Bundespreis Koop.Stadt der Nationalen StadtentwicklungspolitikBautechnik1/202120Wettbewerbe

Kurzfassung

Keine Kurzfassung verfügbar.

x
Weidlich, IngoZum Einsatz von ZFSV im FernwärmeleitungsbauBautechnik1/202121-28Aufsätze

Kurzfassung

Zeitweise fließfähige selbstverdichtende Verfüllbaustoffe (ZFSV) sind Verfüllbaustoffe aus Böden und Baustoffen, die nur unter dem Einfluss der Schwerkraft in Hohlräume fließen und nach einem definierten Zeitraum den Anwendungen entsprechende physikalische Eigenschaften aufweisen. Im Leitungsbau kommen ZFSV zum Einsatz, um bei der offenen Bauweise den Graben zu verfüllen. Vorbehalte gegenüber der Übertragbarkeit vorhandener Berechnungsmethoden für die Rohrstatik und die dauerhafte Gewährleistung der Wiederaushubfestigkeit führten zu einem bis heute andauernden Akzeptanzproblem dieser Verlegemethode im Fernwärmeleitungsbau. Da sich Fernwärmeleitungen nach der Installation infolge eines thermischen Belastungskollektivs im Betrieb ausdehnen, interagieren diese Leitungen immer mit dem anstehenden Bettungsmaterial. Mit dem vorliegenden Aufsatz wird ein Einblick in den Stand des Wissens gegeben und ein vereinfachter Berechnungsansatz vorgeschlagen, der neben deutlich komplexeren Modellen steht und daher die Möglichkeit bietet, aufgrund der Einfachheit Akzeptanzprobleme zu überwinden.

On the use of ZFSV in district heating pipeline construction
Temporarily flowable self-compacting backfill materials (ZFSV) are backfill materials made of soils and building materials that only flow into cavities under the influence of gravity and after a defined period of time exhibit the physical properties appropriate to the application. In pipeline construction, ZFSV are used to backfill the trench. Reservations regarding the transferability of existing calculation methods for pipe statics and the reliability of the ability for re-excavation led to a problem of acceptance of this installation method in district heating pipeline construction that continues until today. As district heating pipes expand during operation after installation due to thermal loads, these pipes always interact with the bedding material. In this paper an overview of the state of the art is given and a simplified calculation approach is proposed, which stands next to much more complex models and therefore offers the possibility to overcome acceptance problems due to its simplicity.

x